Search results for "Transesophageal"
showing 10 items of 54 documents
Diagnosis of culture-negative endocarditis: The role of the Duke criteria and the impact of transesophageal echocardiography
2001
Abstract Background The Duke criteria have been shown to be more sensitive than the von Reyn criteria in the diagnosis of culture-positive endocarditis but to date have not been fully validated for culture-negative endocarditis (CNE). The aim of this study was (1) to compare the diagnostic accuracy of the Duke criteria versus clinical judgment and the von Reyn criteria in CNE and (2) to assess the diagnostic impact of transesophageal echocardiography (TEE) on the Duke criteria in CNE. Methods The study group consisted of 49 patients with suspected CNE in whom the presence (n = 32) or absence (n = 17) of endocarditis was confirmed by surgery, autopsy, or both. All patients underwent transtho…
Coronary embolism in a young patient with nonbacterial thrombotic endocarditis related to antiphospholipid syndrome
2020
myocardial infarction
The presence of infection-related antiphospholipid antibodies in infective endocarditis determines a major risk factor for embolic events.
1999
Abstract OBJECTIVES The impact of infection-associated antiphospholipid antibodies (APA) on endothelial cell activation, blood coagulation and fibrinolysis was evaluated in patients with infective endocarditis with and without major embolic events. BACKGROUND An embolic event is a common and severe complication of infective endocarditis. Despite the fact that APAs are known to be associated with infectious diseases, their pathogenic role in infective endocarditis has not been clearly defined. METHODS The relationship among the occurrence of major embolic events, echocardiographic vegetation size, endothelial cell activation, thrombin generation, fibrinolysis and APA was examined in 91 patie…
Paradoxical embolism through a patent foramen ovale from central venous catheter thrombosis: A potential cause of stroke
2020
Paradoxical embolism refers to a potential condition in which an embolus arising from a venous source crosses into the systemic circulation through a right-to-left cardiac shunt causing an arterial embolism. A 39-year-old woman carrier of a central venous catheter (CVC) without evident risk factors for stroke, developed an acute right homonymous hemianopia during hemodialysis. On neuroimaging, an infarct in the territory of the left posterior cerebral artery was demonstrated. Transesophageal echocardiography revealed a patent foramen ovale (PFO) and a large fluctuating thrombus in the right atrium on the tip of the CVC, thus allowing a diagnosis of ischemic stroke from paradoxical embolism.…
Hypoplasia of the posterior mitral valve leaflet: Don't forget to look beyond the mitral valve.
2020
Hypoplasia of the posterior mitral valve leaflet (PMVL) is a very rare finding in adulthood and can coexist with other congenital heart defects. In this image, a transesophageal echocardiography (TOE) carried out on a 59-year-old woman with a 2-month history of dyspnea revealed a hypoplastic PMVL causing severe mitral regurgitation associated with a secundum-type atrial septal defect (ASD) with left-to-right shunting. This case demonstrates how essential 3-dimensional TOE is for a comprehensive assessment of the mitral valve and to improve the diagnostic accuracy of concomitant congenital heart abnormalities.
Endoscopic Treatment of Transesophageal Echocardiography-Induced Esophageal Perforation
2018
Perforation of the esophagus is the most severe complication of transesophageal echocardiography (TEE) and can lead to mediastinitis, pleural empyema, or peritonitis. Currently, the majority of patients receive operative treatment with only 6% treated endoscopically. We report our experience with endoscopic and conservative approaches.We retrospectively reviewed all patients treated for esophageal perforation and included all patients with perforation caused by TEE. All patients with perforation of the esophagus by TEE probe underwent conservative or endoscopic treatment, drainage of pleural and mediastinal retentions, and adjusted to antibiotic therapy.From January 2004 to December 2014 a …
Percutaneous transvenous direct annuloplasty of a human tricuspid valve using the Valtech Cardioband.
2017
Thoracic Endovascular Aortic Repair (TEVAR) for the treatment of aortic diseases: a position statement from the European Association for Cardio-Thora…
2012
Thoracic endovascular aortic repair (TEVAR) is an emerging treatment modality, which has been rapidly embraced by clinicians treating thoracic aortic disease.1–4 Fundamentally, it is a far less invasive approach than open surgery and its availability and relative ease of application has changed and extended management options in thoracic aortic disease, including in those patients deemed unfit or unsuitable for open surgery. In the operating room, this requires considerable perceptual, cognitive and psychomotor demands on the operators. The dramatic expansion of TEVAR activity has necessarily prompted a requirement to systematically consider the indications, appropriateness, limitations and…
Use of transoesophageal echocardiography in the diagnosis of abscess in infective endocarditis
1995
Transoesophageal echocardiography is invaluable clinically since it accurately images abscess cavities or aneurysms. It provides the information about the site and extension of abscesses which is needed by surgeons to time and define surgical intervention. Early diagnosis is advantageous, and abscesses should be expected in 5%-30% of patients with echocardiographically discernible vegetations. Since there is no 'abscess typical' organism, transoesophageal echocardiographic examination is helpful at the first indication of infective endocarditis, to identify high-risk patients. Involvement of the aortic valve, growth in the size of vegetations, and the presence of spontaneous echo contrast a…
Safety and efficacy of left atrial appendage occlusion with the ACP or Watchman device guided by intracardiac echocardiography from the left atrium
2021
Abstract Background There is a paucity of randomized data regarding the safety and efficacy of the use of intracardiac echocardiography (ICE) from the left atrium (LA) to guide left atrial appendage occlusion (LAAO) procedures under local anesthesia using either of the available devices. Hypothesis The aim of this study was to compare the efficacy and safety of ICE from the LA with transesophageal echocardiography (TEE) for guidance during transcatheter LAAO procedures. Methods Single‐center, cohort study of patients undergoing LAAO with the Amplatzer Cardiac Plug or Watchman device. Procedures were guided by ICE from the LA with local anesthesia (n = 175) or TEE under general anesthesia (n…