Univariate method for background correction in liquid chromatography–Fourier transform infrared spectrometry

2007

An univariate method is proposed for background correction in on-line gradient liquid chromatography-Fourier transform infrared (LC-FTIR) spectrometry using acetonitrile:water as mobile phase components. The method is based on the calculation of the ratio of absorbances (AR) at two characteristic wavenumbers for each spectrum. This parameter is subsequently used to locate the most appropriated eluent spectrum within a reference spectra matrix (RSM) to be subtracted from each spectrum included in the sample chromatogram. To correct minor changes in eluent spectra intensity during the elution of analytes, a correction factor (Kf), defined as the ratio of the absorbance of the sample and the s…

ChromatographyChemistryElutionOrganic ChemistryAnalytical chemistryInfrared spectroscopyGeneral MedicineReference StandardsMass spectrometryBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryMatrix (chemical analysis)ChemometricsAbsorbanceDiuronSpectroscopy Fourier Transform InfraredAtrazineFourier transform infrared spectroscopyChromatography LiquidJournal of Chromatography A
researchProduct

Seafood freshness determination through vapour phase Fourier transform infrared spectroscopy.

2006

Abstract A new vapour-phase manifold has been developed to determine trimethylamine (TMA) in fish and cephalopod samples by Fourier transform infrared (FT-IR) spectroscopy. Samples were treated off-line for 1 h with trichloroacetic acid (TCA), filtered and washed. The obtained extracts were aspirated and alkalinized with NaOH 2.0 M, in an on-line system. TMA was separated from the solution in a gas phase separator and then transported by means of a nitrogen carrier into a home made 10 cm pathlength IR gas cell, where the corresponding FT-IR spectra were acquired by accumulating 30 scans per spectrum with 2 cm−1 nominal resolution. The method was applied to the determination of TMA in natura…

ChromatographyChemistryInfraredAnalytical chemistrySeparator (oil production)chemistry.chemical_elementTrimethylamineBiochemistryNitrogenAnalytical Chemistrysymbols.namesakechemistry.chemical_compoundFourier transformsymbolsEnvironmental ChemistryGas chromatographyFourier transform infrared spectroscopySpectroscopySpectroscopyAnalytica chimica acta
researchProduct

Evaluation of extraction alternatives for Fourier transform infrared spectrometric determination of oil and greases in water

1997

Abstract Liquid-liquid extraction (LLE), solid phase extraction (SPE) and microwave-assisted extraction are evaluated for Fourier transform infrared (FTIR) spectrometric determination of oil and grease in polluted waters. A fast microwave-assisted quantitative procedure is proposed for the total extraction of oil and grease into CCl 4 from water samples, with an irradiation time of 1 min at an exit power of 520 W using closed PTFE vessels. The FTIR quantification of oil and grease is carried out by the measurement of the area under the absorbance spectra in the range between 3058 and 2780 cm −1 , with a baseline established between 3200 and 2700 cm −1 . The analytical features of the propos…

ChromatographyChemistryInfraredExtraction (chemistry)Analytical chemistryIrradiation timeMass spectrometryBiochemistryAnalytical Chemistrysymbols.namesakeFourier transformLiquid–liquid extractionsymbolsEnvironmental ChemistrySolid phase extractionFourier transform infrared spectroscopySpectroscopyAnalytica Chimica Acta
researchProduct

Simultaneous determination of acetylsalicylic acid and caffeine in pharmaceuticals by flow injection with fourier transform infrared detection.

1993

Abstract A fast quality control methodology has been developed for the simultaneous determination of acetylsalicylic acid (ASA) and caffeine in pharmaceuticals by flow injection—Fourier Transform Infrared Spectrometry. The method is based on the solubilization of ASA and caffeine in CH2Cl2 and the use of a flow system to introduce samples and standards in the spectrometer. Two solutions, containing 90 and 110% of the reported concentration of the two active principles in the sample, were employed in order to control the extreme tolerance levels accepted by the International Pharmacopeia for the composition of formulations. A 300 μl volume of each solution was injected in turn, into a carrie…

ChromatographyChemistryInfraredInfrared spectroscopyDosage formAnalytical ChemistryAbsorbancesymbols.namesakechemistry.chemical_compoundFourier transformSolubilizationsymbolsCaffeineQuantitative analysis (chemistry)Talanta
researchProduct

Thermally Induced Isomerisation Kinetics of the 9c11t and 10t12c Conjugated Linoleic Acids in Triacylglycerols as Studied by FT-IR Spectrometry Aided…

2014

Published version of an article from the journal:The Open Spectroscopy Journa. Also available from the publisher:http://dx.doi.org/10.2174/1874383801004010041. Open Access Isomerisation kinetics of the 9c11t and 10t12c Conjugated Linoleic Acids (CLA) in triaclglycerols at isothermal conditions (250, 280 and 325oC) has been studied by infrared spectroscopy. Fifteen micro liter portions of the glycerides were placed in micro glass ampoules and sealed under nitrogen. Several glass tubes containing the same triacylglycerols were then subjected to thermal treatment. The glass tubes were removed at regular time intervals, cut open, and a part of the contents in each glass tube analysed by infrare…

ChromatographyChemistryKineticsOrganic chemistryVDP::Medical disciplines: 700::Basic medical dental and veterinary science disciplines: 710::Medical biochemistry: 726VDP::Mathematics and natural science: 400::Chemistry: 440::Organic chemistry: 441Gas chromatographyConjugated systemFourier transform infrared spectroscopySpectroscopyMass spectrometryIsomerizationThe Open Spectroscopy Journal
researchProduct

Liquid chromatography-Fourier transform infrared spectrometric determination of cholesterol in animal greases

1997

Abstract Stearic acid, cholesterol and cholesteryl palmitate have been separated in less than 14 min by liquid chromatography on a column (3.9 mm i.d.×150 mm) of Nova-Pack C 18 (5 μm) using chloroform–acetonitrile (45 : 55) as mobile phase pumped at 0.5 ml min −1 ; Fourier transform infrared (FTIR) spectrometry was employed for both, general detection at 2868 or 2855 cm −1 and selective detection at 3285 cm −1 for stearic acid and 3526 cm −1 for cholesterol. In all cases a baseline established at 3900 cm −1 , 9-point smoothing and chromatographic peak height measurements were used. The method has been validated by application to the determination of cholesterol in animal greases and fish oi…

ChromatographyChloroformCholesterolMass spectrometryBiochemistryAnalytical Chemistrychemistry.chemical_compoundsymbols.namesakeFourier transformchemistrysymbolsEnvironmental Chemistrylipids (amino acids peptides and proteins)Petroleum etherStearic acidFourier transform infrared spectroscopySpectroscopySaponificationAnalytica Chimica Acta
researchProduct

Comparison of two vibrational procedures for the direct determination of mancozeb in agrochemicals.

2007

The direct determination of mancozeb in agrochemicals has been made by diamond attenuated total reflectance (ATR) Fourier transform infrared spectroscopy in the middle range (DATR-MIR) and diffuse reflectance infrared Fourier transform spectroscopy in the near range (DR-NIR) methods using in both cases a previous identification of the samples using a dendrographic classification and an appropriate partial least squares (PLS) calibration established from a set of nine external standards and optimized for each type of sample. It was analyzed a heterogeneous population of 11 samples obtained from the Spanish market, containing different co-formulated products, such as fosetyl-Al, copper oxychl…

ChromatographyDiffuse reflectance infrared fourier transformChemistryAttenuated total reflectionDirect methodPartial least squares regressionCalibrationAnalytical chemistryInfrared spectroscopyFourier transform infrared spectroscopyFourier transform spectroscopyAnalytical ChemistryTalanta
researchProduct

Filter-based infrared detectors for high temperature size exclusion chromatography analysis of polyolefins: calibration with a small number of standa…

2012

Infrared detection has been shown to be very appropriate for high temperature analysis of polyolefins. After some early reports in which dispersive or single-band filter-based detectors were applied, Fourier transform detectors have been described for this application, in order to improve the method sensitivity. Modern simple filter-based detectors prove, however, comparable sensitivity while providing a number of practical advantages when coupled to chromatographic systems: reduced cell volume, simplified hardware, continuous generation of absorbance chromatograms, as well as simpler data collection and processing. A practical method for calibration, using multiple-band signals obtained wi…

ChromatographyHot TemperatureResolution (mass spectrometry)Spectrophotometry InfraredChemistryOrganic ChemistryDetectorGeneral MedicinePolyenesSignal-To-Noise RatioBiochemistryAnalytical ChemistryAbsorbanceMolecular Weightsymbols.namesakeSignal-to-noise ratioFourier transformFilter (video)CalibrationMultivariate AnalysisCalibrationsymbolsChromatography GelLinear ModelsSensitivity (control systems)Journal of chromatography. A
researchProduct

Miniature diamond-anvil cells for FTIR-microspectroscopy of small quantities of biosamples.

2018

Fourier transform infrared (FTIR) spectroscopy techniques and data analyses have become widely available, are easy to use, and are convenient for studies of various biosamples, especially in biomedical science. Yet, cultivation of cells and purification of cell components are costly, often methodically challenging, and time and labor consuming. Therefore, reduction of the sample amount is of high value. Here we propose a novel method for the analysis of small quantities of biosamples by FTIR-microscopy of dry films using a diamond-anvil cell (DAC). This approach allows us to decrease the sample volume at least a hundred times compared to that for a high-throughput screening device (HTS-XT, …

ChromatographyMaterials science010401 analytical chemistry02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesBiochemistryDiamond anvil cell0104 chemical sciencesAnalytical ChemistrySample volumeHomogeneousElectrochemistryEnvironmental ChemistryFourier transform infrared spectroscopy0210 nano-technologySpectroscopyBiochemical markersThe Analyst
researchProduct

Essential oil counterfeit identification through middle infrared spectroscopy

2018

Abstract Infrared spectroscopy (FTIR) has been employed for a fast quality control of commercial essential oils from different plant species. 47 samples were obtained from Algerian and Spanish market and directly measured, without any previous treatment, by attenuated total reflectance Fourier transform Infrared spectroscopy (ATR-FTIR), in the wavenumber region between 4000 and 550 cm−1. Pure essential oils were obtained by hydro- and steam-distillation extraction methods and their ATR spectra obtained. Results found evidenced the presence of solvents in some commercial formulations and permitted a rapid authentication of pure essential oils correctly extracted from those diluted. The propo…

ChromatographyMaterials science010405 organic chemistry010401 analytical chemistryInfrared spectroscopy01 natural sciencesEnvironmentally friendly0104 chemical sciencesAnalytical Chemistrylaw.inventionlawAttenuated total reflectionMiddle infraredPlant speciesFourier transform infrared spectroscopySpectroscopySpectroscopyEssential oilMicrochemical Journal
researchProduct