Search results for "Transient"

showing 10 items of 623 documents

Structural Health Monitoring of Cracked Beam by the Dual Reciprocity Boundary Element Method

2012

In this paper a 2D boundary element model is used to characterize the transient response of a piezoelectric based structural health monitoring system for cracked beam. The BE model is written for piezoelectric non-homogeneous problem employing generalized displacements. The dual reciprocity method is used to write the mass matrix in terms of boundary parameters only. The multidomain boundary element technique is implemented to model non-homogeneous and cracked configuration, unilateral interface conditions are also considered to prevent the physical inconsistence of the overlapping between interface nodes belonging to the crack surfaces. To assess the reliability and the effectiveness of th…

EngineeringStructural health monitoringbusiness.industryPiezoelectric sensorBEMGeneral EngineeringStructural engineeringMass matrixPiezoelectricityFracture MechanicModalReciprocity (electromagnetism)Transient responseStructural health monitoringbusinessSettore ING-IND/04 - Costruzioni E Strutture AerospazialiBoundary element method
researchProduct

A New Generalized Robust Predictive Current Control for Grid-Connected Inverters Compensates Anti-Aliasing Filters Delay

2016

In this paper, a new predictive control for grid-connected inverters is presented, which provides the best performance in terms of transient response and stability margins when analog filters in current sensing circuits are used. These filters are necessary to avoid aliasing in the A/D conversion process, which causes an important ripple on injected current into the grid and increases the total harmonic distortion. However, predictive controls are very sensitive to delays on the acquisitions, so when such anti-aliasing filters are used a reduction of stability margins is produced and the transient response is affected. The proposed predictive control allows to compensate the effect of the f…

EngineeringTotal harmonic distortionbusiness.industry020209 energy020208 electrical & electronic engineeringRipple02 engineering and technologyFilter (signal processing)Anti-aliasingAnalogue filterModel predictive controlControl and Systems EngineeringAliasingControl theory0202 electrical engineering electronic engineering information engineeringElectronic engineeringTransient responseElectrical and Electronic EngineeringbusinessIEEE Transactions on Industrial Electronics
researchProduct

Influence of MV distribution networks structure on voltage dips propagation

2003

In this paper, transient behaviour due to voltage dips which occur in electric power MV distribution networks as a consequence of a fault by using an improved ATP circuit-breaker model are reported. The circuit-breaker is simulated by using a tool written in MODELS language and by arranging a time-variable differential arc-conductance based on the combination of Mayr's and Cassie's equations. An accurate analysis of the transient subsequent to circuit-breaker operation, in different fault conditions, are reported in order to show how the amplitude of the dip depends on the fault type, location and network structure.

EngineeringTransient recovery voltageElectrical loadbusiness.industryElectrical engineeringHardware_PERFORMANCEANDRELIABILITYPower factorVoltage optimisationFault (power engineering)TopologyConstant power circuitTransient (oscillation)businessVoltagePowerTech Budapest 99. Abstract Records. (Cat. No.99EX376)
researchProduct

Forces and flow structures evolution on a car body in a sudden crosswind

2014

A vehicle driver is commonly exposed to strong side air flows, for example when passing through a wind gust. The aerodynamic efforts generated in these situations may induce undesired lateral deviations, which can lead to dramatic effects, if the driver is surprised. In order to simulate a sudden yaw angle change on a moving vehicle, a double wind tunnel facility, adapted from the one of Ryan, Dominy, 2000. Wake Surveys Behind a Passenger Car Subjected to a Transient Cross-wind Gust. SAE Technical Paper No. 2000-01-0874 is developed. Two Windsor car body models, differing from their rear geometry, are analysed. The transient evolution of the side force and yaw moment aerodynamic coefficient…

EngineeringUnsteady aerodynamicsMeteorologyMécanique des fluidesFlow (psychology)WakeRoad vehiclessymbols.namesakeUnsteady effortsCivil and Structural EngineeringWind tunnelRenewable Energy Sustainability and the Environmentbusiness.industryMechanical EngineeringAerodynamicsMechanicsMécaniqueVorticesVortexEuler anglesPIVsymbolsTransient (oscillation)Unsteady crosswindbusinessCrosswindJournal of Wind Engineering & Industrial Aerodynamics
researchProduct

On the Problems of Symbol-Spaced Tapped-Delay-Line Models for WSSUS Channels

2007

Article from the journal: Wireless Communications and Mobile Computing The deposited fulltext is a preprint of the definitive article at Wiley Interscience http://dx.doi.org/10.1002/wcm.683 This paper analyzes the validity and statistical behavior of symbol-spaced tapped-delay-line (SSTDL) models for wide-sense stationary uncorrelated scattering (WSSUS) mobile radio channels. SSTDL models are obtained by sampling the channel impulse response (CIR) in delay domain at a rate equal to the reciprocal of the symbol duration. They were proposed more than four decades ago as canonical channel models for band-limited timevariant linear (TVL) systems, and are nowadays widely in use for assessing the…

EngineeringWSSUS modelbusiness.industryContext (language use)Correlation function (quantum field theory)Sampling (signal processing)VDP::Technology: 500::Information and communication technology: 550::Telecommunication: 552Line (geometry)Electronic engineeringTransient responsebusinessAlgorithmReciprocalComputer Science::Information TheoryCommunication channel2007 IEEE 66th Vehicular Technology Conference
researchProduct

A Comparative Analysis of the Reliability of Simple and Two-Level Checkpointing Techniques in two Different Distributed Industrial Control System Arc…

2003

In Distributed industrial control systems it is necessary to guarantee certain reliability level. In this sense, Checkpointing and Rollback techniques offer interesting possibilities to achieve fault tolerance without appreciable cost and complexity increment. Several Checkpointing techniques have been proposed. Most of them suppose the presence of stable storage in the system. But distributed industrial control systems usually do not dispose of this kind of storage. So, another storage strategy has to be employed. If Checkpoints were locally stored (Simple Checkpointing), the system tolerates only transient faults. If Checkpoints were locally, at the same node, and, additionally, at anothe…

Engineeringbusiness.industryApplied MathematicsNode (networking)Reliability (computer networking)Distributed computingFault toleranceIndustrial control systemReliability engineeringModeling and SimulationTransient (computer programming)Stable storageDistributed control systembusinessRollbackSystems Analysis Modelling Simulation
researchProduct

Consensus-based Distributed Intrusion Detection for Multi-Robot Systems

2008

This paper addresses a security problem in robotic multi-agent systems, where agents are supposed to cooperate according to a shared protocol. A distributed Intrusion Detection System (IDS) is proposed here, that detects possible non-cooperative agents. Previous work by the authors showed how single monitors embedded on-board the agents can detect non- cooperative behavior, using only locally available information. In this paper, we allow such monitors to share the collected information in order to overcome their sensing limitation. In this perspective, we show how an agreement on the type of behavior of a target-robot may be reached by the monitors, through execution of a suitable consensu…

Engineeringbusiness.industryDistributed computingReal-time computingIntrusion detection systemDecentralised systemUpper and lower boundsComputer Science::Multiagent SystemsConsensusSettore ING-INF/04 - AutomaticaConvergence (routing)Transient (computer programming)Intrusion detectionbusinessIntelligent transportation systemProtocol (object-oriented programming)set--valued consensus algorithm
researchProduct

A fuel cell-battery hybrid power supply for portable applications

2010

Today, academic and industrial research is addressed to fuel cell based hybrid power supply in many fields of applications including stationary, automotive and portable electronics. Increasing source runtime, speeding up the transient response while minimizing weight, volume and cost of the power supply system are key requirements of all applications. According to the particular application, the power management system is optimized for a specific feature. In this paper, a fuel cell–battery hybrid power supply for a Digital Camera is proposed, although the control algorithm can be efficiently applied to any portable device. Thanks to an innovative control on the input power, any fuel cell pr…

Engineeringbusiness.industryElectrical engineeringAutomotive industryAutomotive electronicsSettore ING-INF/01 - ElettronicaPower electronicsControl systemfuel cell hybrid power supplyTransient responseHybrid powerSwitched-mode power supply applicationsbusinessPower management system
researchProduct

An efficient diagnostic technique for distribution systems based on under fault voltages and currents

2010

Service continuity is one of the major aspects in the definition of the quality of the electrical energy, for this reason the research in the field of faults diagnostic for distribution systems is spreading ever more. Moreover the increasing interest around modern distribution systems automation for management purposes gives faults diagnostics more tools to detect outages precisely and in short times. In this paper, the applicability of an efficient fault location and characterization methodology within a centralized monitoring system is discussed. The methodology, appropriate for any kind of fault, is based on the use of the analytical model of the network lines and uses the fundamental co…

Engineeringbusiness.industryFaults diagnosis Fault location and characterization Distribution systems managementComputationSystem identificationEnergy Engineering and Power TechnologyFault (power engineering)AutomationFault indicatorlaw.inventionSettore ING-IND/33 - Sistemi Elettrici Per L'EnergiaMicroprocessorlawElectrical networkElectronic engineeringTransient (oscillation)Electrical and Electronic EngineeringbusinessElectric Power Systems Research
researchProduct

A Phase-Locked Loop for the Synchronization of Power Quality Instruments in the Presence of Stationary and Transient Disturbances

2007

Power quality instrumentation requires accurate fundamental frequency estimation and signal synchronization, even in the presence of both stationary and transient disturbances. In this paper, the authors present a synchronization technique for power quality instruments based on a single-phase software phase-locked loop (PLL), which is able to perform the synchronization, even in the presence of such disturbances. Moreover, PLL is able to detect the occurrence of a transient disturbance. To evaluate if and how the synchronization technique is adversely affected by the application of stationary and transient disturbing influences, appropriate testing conditions have been developed, taking int…

Engineeringbusiness.industryFundamental frequencySignalSynchronizationPhase-locked loopTransducerInstrument synchronization phase-locked loop (PLL) control power quality transient disturbancesControl theoryElectronic engineeringInstrumentation (computer programming)Transient (oscillation)Electrical and Electronic EngineeringbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheInstrumentationVoltageIEEE Transactions on Instrumentation and Measurement
researchProduct