A DC behavioral electrical model for quasi-linear spin-valve devices including thermal effects for circuit simulation
2011
An advanced model for quasi-linear spin-valve (SV) structures is presented for circuit simulation purposes. The model takes into account electrical and thermal effects in a coupled way in order to allow a coherent representation of the sensor physics for design purposes of electronics applications based on these sensor devices. The model was implemented in Verilog-A and used in a commercial circuit simulator. For testing the model, different SV structures have been specifically fabricated and measured. The characterization included DC measurements as well as steady-state and transient thermal analysis. From the experimental data, the parameters of the model have been extracted. The model re…
Effects of electrical and mechanical parameters on the transient voltage stability of a fixed speed wind turbine
2011
Abstract In this paper the dynamic behaviour of a wind turbine connected to the grid is examined. The model of the fixed speed wind turbine has been developed with the Simulink simulation tool (Matlab Inc.) It is composed of the induction generator, the shaft system, an aerodynamic model of the wind turbine rotor and the pitch control system. Using this model, a three-phase fault is applied close to the wind turbine and cleared by disconnecting the faulty line. The rigorous implementation of the simulink model allowed the authors to evaluate the exact dependence of various electrical parameters for the induction generator on voltage stability. Furthermore, the effects of wind turbine mechan…
Using input shaping and pressure feedback to suppress oscillations in slewing motion of lightweight flexible hydraulic crane
2015
This paper presents a method to actively reduce vibrations in the flexible mechanical structure of a hydraulically actuated vehicle loader crane. Based on information on the natural frequency and damping of a simplified model of the crane an input shaping scheme is set up to control the proportional valve leading to substantially reductions in oscillations. The method is compared and combined with a pressure feedback control of the proportional valve that actively suppresses transient variations in pressure. A full scale vehicle loader crane is used in the experimental verification of the method, and the motion of the tool point of the crane is measured by a high precision laser tracker. Th…
On the dynamic behavior of piezoelectric active repair by the boundary element method
2011
The dynamic behavior of piezoelectric active repair bonded on cracked structures is analyzed in this article. The boundary element code used to perform the simulations is implemented in the framework of piezoelectricity in order to model the coupling between the elastic and the electric fields, which represents the most important feature of piezoelectric media. The fracture mechanics problem, i.e. the crack, as well as the bonding layer between the host structure and the active patch is modeled by means of the multidomain technique provided with an interface spring model. More particularly, the spring interface model allows considering the bonding layer as a zero-thickness elastic ply char…
TRACE and RELAP5 Codes for Beyond Design Accident Condition Simulation in the SPES3 Facility
2012
Code validation on qualified experimental data is a fundamental issue in the design and safety analyses of nuclear power plants. The SPES3 facility is being built at the SIET laboratories for an integral type SMR simulation, in the frame of an R&D program on nuclear fission, funded by the Italian Ministry of Economic Development and led by ENEA. The facility, based on the IRIS reactor design, reproduces the primary, secondary and containment systems with 1:100 volume scale, full elevation and prototypical fluid and thermal-hydraulic conditions. It is suitable to test the plant response to design and beyond design accidents in order to verify the effectiveness of the primary and containm…
Evaluation of radiated EMI in 42 V vehicle electrical systems by FDTD simulation
2007
In this paper a full 3D numerical scheme, based on the finite difference time domain method, is used to predict the electromagnetic radiated interference generated by 42 V vehicle power electronic driven electrical loads. An experimental set-up has been arranged on purpose in order to validate the proposed simulation tool. To this aim, the features of a semi-anechoic electromagnetic chamber have been exploited in order to operate in a shielded test site for the measurement of near field radiated emissions. Two different three-dimensional geometrical configurations of realistic vehicle installations of the loads, are studied. A comparative analysis among measured and computed results is perf…
Diagnosis of mechanical unbalance for double cage induction motor load in time-varying conditions based on motor vibration signature analysis
2013
This paper investigates the detectability of mechanical unbalance in double cage induction motor load using motor vibration signature analysis technique. Rotor imbalances induce specific harmonic components in electrical, electromagnetical, and mechanical quantities. Harmonic components characteristic of this category of rotor faults, issued from vibration signals analysis, are closely related to rotating speed of the rotor, which complicates its detection under non-stationary operating conditions of the motor. Firstly, experimental results were performed first under healthy and mechanical load unbalance cases, for different load levels under steady-state operating conditions to evaluate th…
Wind Turbine Mechanical Characteristics and Grid Parameters Influence on the Transient Voltage Stability of a Fixed Speed Wind Turbine
2008
This paper describes the effect of wind turbine mechanical characteristic of construction and grid parameters on the transient voltage stability of a fixed speed wind turbine (FSWT) connected to a simple grid. The model of FSWT has been developed in Matlab/Simulink. Using this model, a three-phase fault is applied close to the wind turbine (WT) and cleared by disconnecting the faulted line. The effects of mechanical construction of WT and of grid parameters on the voltage stability of this simple case are evaluated and discussed. The considered parameters are the inertia coefficient of the WT, the short-circuit power at the connection bus, the hub-generator resonant frequency, the wind spee…
Effects of Electrical Parameters of Induction Generator on the Transient Voltage Stability of a Fixed Speed Wind Turbine
2008
This paper describes the effect of electrical parameters of the induction generator on the transient voltage stability of a fixed speed wind turbine connected to a simple grid; the dynamic behavior of a wind turbine connected to the grid is examined. The model of the fixed speed wind turbine has been developed in the simulation tool Matlab/Simulink. Itpsilas composed by the induction generator, the shaft system, the aerodynamic model of the wind turbine rotor and the pitch control system. Using this model, a three-phases fault is applied close to the wind turbine and cleared by disconnecting the faulted line. The effect of different electrical parameters of the induction generator on the vo…
A General Mathematical Model for non-Redundant Fault-Tolerant Inverters
2011
Industrial systems able to release trusted services is an integrated concept that resumes the attributes of availability, reliability, safety, integrity, and maintainability. In power electronics this can be aimed via the introduction of fault tolerant architectures. While In the past technical literature the mathematical modeling problem for non-redundant converters was fronted studying separately the cases of fault leg by leg, in this paper a general model able to include the three possible cases of leg faults with a unique set of equation is introduced and discussed. The same model allows to evaluate the DC Link transient and steady state evolution and also allows to develop with much ea…