Search results for "Trap"
showing 10 items of 2144 documents
Two-dimensional spectroscopy for the study of ion Coulomb crystals
2015
Ion Coulomb crystals are currently establishing themselves as a highly controllable test-bed for mesoscopic systems of statistical mechanics. The detailed experimental interrogation of the dynamics of these crystals however remains an experimental challenge. In this work, we show how to extend the concepts of multi-dimensional nonlinear spectroscopy to the study of the dynamics of ion Coulomb crystals. The scheme we present can be realized with state-of-the-art technology and gives direct access to the dynamics, revealing nonlinear couplings even in the presence of thermal excitations. We illustrate the advantages of our proposal showing how two-dimensional spectroscopy can be used to detec…
Emission-Line Intensity Ratios in F[CLC]e[/CLC] [CSC]xvii[/CSC] Observed with a Microcalorimeter on an Electron Beam Ion Trap
2000
We report new observations of emission line intensity ratios of Fe XVII under controlled experimental conditions, using the National Institute of Standards and Technology electron beam ion trap (EBIT) with a microcalorimeter detector. We compare our observations with collisional-radiative models using atomic data computed in distorted wave and R-matrix approximations, which follow the transfer of the polarization of level populations through radiative cascades. Our results for the intensity ratio of the 2p6 1S0-2p53d 1P1 15.014 A line to the 2p6 1S0-2p53d 3D1 15.265 A line are 2.94 ± 0.18 and 2.50 ± 0.13 at beam energies of 900 and 1250 eV, respectively. These results are not consistent wit…
Transmission Microscopy with Nanometer Resolution Using a Deterministic Single Ion Source.
2015
We realize a single particle microscope by using deterministically extracted laser-cooled ^{40}Ca^{+} ions from a Paul trap as probe particles for transmission imaging. We demonstrate focusing of the ions to a spot size of 5.8±1.0 nm and a minimum two-sample deviation of the beam position of 1.5 nm in the focal plane. The deterministic source, even when used in combination with an imperfect detector, gives rise to a fivefold increase in the signal-to-noise ratio as compared with conventional Poissonian sources. Gating of the detector signal by the extraction event suppresses dark counts by 6 orders of magnitude. We implement a Bayes experimental design approach to microscopy in order to ma…
Computer simulation of models for the structural glass transition
2008
In order to test theoretical concepts on the glass transition, we investigate several models of glassy materials by means of Monte Carlo (MC) and Molecular Dynamics (MD) computer simulations. It is shown that also simplified models exhibit a glass transition which is in qualitative agreement with experiment and that thus such models are useful to study this phenomenon. However, the glass transition temperture as well as the structural properties of the frozen-in glassy phase depend strongly on the cooling history, and the extrapolation to the limit of infinitely slow cooling velocity is nontrivial, which makes the identification of the (possible) underlying equilibrium transition very diffi…
Single Ion Thermal Wave Packet Analyzed Via Time-Of-Flight Detection
2021
Abstract A single 40Ca ion is confined in the harmonic potential of a Paul trap and cooled to a temperature of a few mK, with a wave packet of sub-μm spatial and sub-m s−1 velocity uncertainty. Deterministically extracted from the Paul trap, the single ion is propagating over a distance of 0.27 m and detected. By engineering the ion extraction process on the initial wave packet, theoretically modeling the ion trajectories, and studying experimentally the time-of-flight distribution, we directly infer the state of the previously trapped ion. This analysis allows for accurate remote sensing of the previous motional excitation in the trap potential, both coherently or incoherently. Our method …
A Novel Method for the Measurement of Half-Lives and Decay Branching Ratios of Exotic Nuclei
2019
A novel method for simultaneous measurement of masses, Q-values, isomer excitation energies, half-lives and decay branching ratios of exotic nuclei has been demonstrated. The method includes first use of a stopping cell as an ion trap, combining containment of precursors and decay-recoils for variable durations in a cryogenic stopping cell (CSC), and afterwards the identification and counting of them by a multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS). Feasibility has been established by recording the decay and growth of $^{216}$Po and $^{212}$Pb (alpha decay) and of $^{119m2}$Sb (t$_{1/2}$ = 850$\pm$90 ms) and $^{119g}$Sb (isomer transition), obtaining half-lives and bran…
Penning-trap mass measurements of neutron-deficient Rb and Sr isotopes
1993
Abstract The Penning-trap mass spectrometer ISOLTRAP installed at the on-line mass separator ISOLDE 2 at CERN has been used for mass determination of 75–87 Rb and 78–83,87 Sr. Ions are captured in a Penning trap and their cyclotron frequency ω c = ( q m )B in the trapping field B is measured. Ratios of these frequencies lead to the determination of the atomic mass of these isotopes. A resolving power of typically m Δm = 10 6 and an accuracy of δm ≈10 keV is obtained. The mass of 78 Sr is measured for the first time and, in most cases, the mass values of the other isotopes are significantly improved. The experimental masses are compared with theoretical predictions.
High-precision masses of neutron-deficient rubidium isotopes using a Penning trap mass spectrometer
2007
The atomic masses of the neutron-deficient radioactive rubidium isotopes $^{74-77,79,80,83}$Rb have been measured with the Penning trap mass spectrometer ISOLTRAP. Using the time-of-flight cyclotron resonance technique, relative mass uncertainties ranging from $1.6 \times 10^{-8}$ to $5.6 \times 10^{-8}$ were achieved. In all cases, the mass precision was significantly improved as compared with the prior Atomic-Mass Evaluation; no significant deviations from the literature values were observed. The exotic nuclide $^{74}$Rb with a half-life of only 65 ms, is the shortest-lived nuclide on which a high-precision mass measurement in a Penning trap has been carried out. The significance of these…
Astrophysics and spectroscopy with microcalorimeters on an electron beam ion trap
2003
The importance of the combination of electron beam ion trap (EBIT) spectroscopy with X-ray microcalorimeters in the field of astrophysics was discussed. X-ray astronomy involves heavily charged ion instruments , especially EBIT, to obtain improved quality atomic data. In this regard, the research program at the National Institute of Standards and Technology, which uses X-ray spectroscopic methods to study plasma and atomic physics, was also discussed.
Systematic studies of the accuracy of the Penning trap mass spectrometer JYFLTRAP
2009
Abstract Measurements to quantify the mass-dependent systematic effect and the residual uncertainty of the JYFLTRAP setup have been performed with carbon-cluster ions. The primary quantities reported in this work are a mass-dependent uncertainty of σ m ( r ) / r = ( 7.8 ± 0.3 × 10 - 10 / u ) × Δ m and a residual uncertainty of σ res ( r ) / r = 1.2 × 10 - 8 for the JYFLTRAP mass spectrometer. By restricting the mass difference between the reference ion and ion of interest to | m meas - m ref | ≤ 24 , the values for the mass-dependent effect and the corresponding residual uncertainty are σ m , lim ( r ) / r = ( 7.5 ± 0.4 × 10 - 10 / u ) × Δ m and σ res , lim ( r ) / r = 7.9 × 10 - 9 , respec…