Search results for "ULTRASONOGRAPHY"
showing 10 items of 930 documents
Three-dimensional ultrasound evaluation of ovarian masses.
1995
Seventy-six women with ovarian masses first detected with two-dimensional (2D) ultrasound were then evaluated with three-dimensional (3D) ultrasound. Two-dimensional ultrasound detected four of five ovarian malignancies. One additional ovarian carcinoma was diagnosed by 3D scanning. Observation of papillary projections, characteristics of cystic walls, and the extent of capsular infiltration of tumors was superior with 3D ultrasound as was the calculation of ovarian volume. Fifty-seven of the women studied underwent surgery within 7 days of 3D ultrasound evaluation. Histologic examination of surgical specimens confirmed the 3D sonographic diagnoses. There was one false positive and one fals…
Control of intrauterine device insertion with three-dimensional ultrasound: is it the future?
1996
A comparative study was designed to determine whether three-dimensional transvaginal sonography (3D-TVS) offered advantages over two-dimensional transvaginal sonography (2D-TVS) for the identification and location of IUDs in 66 asymptomatic women. Hysteroscopy was performed in cases in which there was a discrepancy between the information obtained by both methods (n = 14). In eight cases (12.2%) the IUD was misidentified with 2D-TVS. In six cases (9.1%) it was not possible to identify the device model with 2D-TVS. In two cases (3.0%) 2D-TVS failed to identify the position of the device. In contrast, all IUDs were identified and located accurately with 3D-TVS. © 1996 John Wiley & Sons, Inc.
Operative Hysteroscopy Ten Years' Experience
1994
Transcranial Doppler ultrasonography in the assessment of cerebral circulation arrest: improving sensitivity by trancervical and transorbital carotid…
2009
INTRODUCTION: Transcranial Doppler (TCD) can detect the cerebral circulation arrest (CCA) in brain death. TCD is highly specific, but less sensitive because of false-negatives accounting for up to 10%. The aim of the study was to explore the diagnostic accuracy of TCD and to determine whether it can be augmented by strategies such as the insonation of the extracranial internal carotid artery (ICA) and sequential examinations. METHODS: Data of 184 patients, who met clinical criteria of brain death, observed from 1998 through 2006, were retrospectively reviewed. The study of cerebral arteries was performed through the transtemporal approach, suboccipital insonation of the vertebro-basilar sys…
Congenital hepatic mesenchymal hamartoma associated with mesenchymal stem villous hyperplasia of the placenta: case report.
2005
A newborn with an unusual association of hepatic mesenchymal hamartoma and mesenchymal stem villous hyperplasia of the placenta is presented. At birth, the large hepatic mass caused severe respiratory distress necessitating early surgical intervention. This report on the association of hepatic mesenchymal hamartoma and mesenchymal stem villous hyperplasia of the placenta strongly suggests a common pathogenetic origin of the 2 lesions.
Quantitative corneal anatomy in emmetropic subjects.
2006
PURPOSE Currently there is little information available about the corneal thickness values of healthy emmetropic subjects. Therefore, the authors decided to analyze the corneal thickness in healthy emmetropic subjects. METHODS The authors analyzed the difference in thickness values between the thinnest corneal site and the central and paracentral cornea in 124 eyes of 124 healthy emmetropic white subjects. RESULTS The mean difference between the thinnest site of the cornea and the thickness values obtained in the areas analyzed was as follows: 12+/-6 microm center; 140+/-19 microm superonasal; 133+/-23 microm nasal; 117+/-26 microm inferonasal; 122+/-19 microm superotemporal ; 89+/-22 micro…
Optic disc drusen in tilted disc
2017
Purpose To investigate if a congenital anomaly of the head of the optic nerve like such as tilted disc can be a risk factor for the development of optic disc drusen. Methods The study was performed retrospectively on the files of 47 patients with optic disc drusen. The diagnosis was confirmed by fluorescein angiography and B-scan ultrasonography. The authors examined the fundus photographs and the fluorescein angiographies of these patients looking for the presence of tilted discs. Results Two of the 47 patients with optic nerve drusen had tilted discs as well, about twice the expected rate. Both cases presented a parapapillary hemorrhage. Conclusions The concomitant presence of tilted disc…
Isolated Endometriosis on the Rectus Abdominis Muscle in Women without a History of Abdominal Surgery: a Rare and Intriguing Finding
2009
We report 2 rare cases of endometriosis on the rectus abdominal muscle diagnosed incidentally during an operation for inguinal hernia repair in women with no surgical history. Two women sought medical attention for a mass found in the pubic abdominal wall. Only 1 woman reported occasional pain. At physical examination in both women, an ovoid swelling in the right pubic area was felt. One woman experienced pain on palpation, and one reported slight discomfort. Ultrasonography demonstrated a heterogeneous hypoechogenic formation with indistinct edges; diagnosis was difficult. Routine clinical and instrumental (pelvic ultrasonography) gynecologic examination in both patients performed shortly …
Acute Endocrine and Force Responses and Long-Term Adaptations to Same-Session Combined Strength and Endurance Training in Women
2015
This study examined acute hormone and force responses and strength and endurance performance and muscle hypertrophy before and after 24 weeks of same-session combined strength and endurance training in previously untrained women. Subjects were assigned 1 of 2 training orders: endurance preceding strength (E + S, n = 15) or vice versa (S + E, n = 14). Acute force and hormone responses to a combined loading (continuous cycling and a leg press protocol in the assigned order) were measured. Additionally, leg press 1 repetition maximum (1RM), maximal workload during cycling (Wmax), and muscle cross-sectional area (CSA) were assessed. Loading-induced decreases in force were significant (p < 0.01–…
Doppler and B-mode ultrasound for avascular nephrotomy.
1983
AbstractDoppler sonography for intraoperative localization of the intrarenal arteries combined with B-scan sonography for intraoperative visualization of stones allows complete stone removal via small radial nephrotomies for which clamping of the renal artery is no longer necessary. Since September 1980 we used this technique on 35 patients with staghorn or recurrent calculi. The main advantages of this technique are exact and quick stone localization, minimal loss of renal function owing to preservation of the intrarenal vascular system, and no need for renal ischemia and cooling.