Search results for "ULTRASOUND"
showing 10 items of 1259 documents
The Prevalence of NAFLD and Fibrosis in Bariatric Surgery Patients and the Reliability of Noninvasive Diagnostic Methods
2020
Background. Bariatric surgery patients have a higher prevalence of nonalcoholic fatty liver (NAFL) than the general population; however, its assessment and the accurate staging of fibrosis are often complicated because noninvasive tests are not very accurate in patients with morbid obesity, and liver biopsy cannot be performed as a routine exam. The aim of this study was to evaluate (A) the histological prevalence of NAFL, nonalcoholic steatohepatitis (NASH), and fibrosis in patients undergoing bariatric surgery; (B) the reliability of ultrasound (US) in diagnosing NAFL; and (C) the reliability of various fibrosis scoring systems for defining fibrosis. Methods. US and intraoperative liver b…
Evaluation of Mesorectal Fascia in Mid and Low Anterior Rectal Cancer Using Endorectal Ultrasound Is Feasible and Reliable
2014
Accuracy of MRI in assessing mesorectal fascia and predicting circumferential resection margin decreases in low anterior rectal tumors.The purpose of this work was to evaluate the accuracy of endorectal ultrasound in predicting the pathologic circumferential resection margin in low rectal anterior tumors and to compare it with MRI findings.This was a prospective series comparing the preoperative circumferential resection margin assessed by endorectal ultrasound and MRI with pathologic examination.The study was conducted by a specialized colorectal multidisciplinary team at a tertiary teaching hospital.Between 2002 and 2008, 76 patients with mid to low rectal cancer were preoperatively evalu…
Modified Wong's Classification Improves the Accuracy of Rectal Cancer Staging by Endorectal Ultrasound and MRI
2013
BACKGROUND: Douglas Wong proposed a new classification of tumor penetration in the rectal wall (T stage) in an attempt to incorporate the prognostic heterogeneity of T3 rectal cancers into the preoperative staging. OBJECTIVE: This study aimed to evaluate if the accuracy of endorectal ultrasound and MRI in predicting rectal cancer T staging improves when using a modified Wong's classification. DESIGN: This prospective series compares local standard TN staging and a modified Wong's classification. SETTINGS: This study was conducted by a specialized Colorectal Multidisciplinary Team at a tertiary teaching hospital. PATIENTS: Seventy patients underwent surgery for middle or low rectal cancer be…
Splenic hemangiomas: contrast-enhanced sonographic findings
2012
Objectives The purpose of this study was to illustrate the baseline appearance and enhancement patterns of splenic hemangiomas on contrast-enhanced sonography. Methods Two experienced radiologists retrospectively reviewed by consensus baseline and contrast-enhanced sonographic examinations of 27 patients (14 women and 13 men; mean age, 58.7 years) with 27 splenic hemangiomas (mean size, 2 cm) confirmed by splenectomy, biopsy, computed tomography, and magnetic resonance imaging and follow-up. Results On baseline sonography, 77.8% of the lesions showed a homogeneous echo texture that was mainly hyperechoic. Color Doppler imaging did not show any signal in 81.5% of the cases. After contrast ag…
Influence of heart rate in the selection of the optimal reconstruction window in routine clinical multislice coronary angiography
2008
Purpose. The aim of our study was to assess the influence of heart rate on the selection of the optimal reconstruction window with 40-slice multidetector-row computed tomography (40-MDCT) coronary angiography. Materials and methods. We studied 170 patients (114 men, age 60 +/- 11.3 years) with suspected or known coronary artery disease with 40-MDCT coronary angiography. Patients [mean heart rate (HR) 62.9 +/- 9.3 bpm, range 42-94 bpm] were clustered in two groups (group A: HR <= 65 bpm; group B: HR >65 bpm). Multiphase reconstruction data sets were obtained with a retrospective electrocardiogram (ECG)-gated 40-MDCT coronary angiography scan from 0% to 95% every 5% of the R-R interval.…
Achilles tendon stiffness is unchanged one hour after a marathon
2012
Overuse-induced injuries have been proposed as a predisposing factor for Achilles tendon (AT) ruptures. If tendons can be overloaded, their mechanical properties should change during exercise. Because there data are lacking on the effects of a single bout of long-lasting exercise on AT mechanical properties, the present study measured AT stiffness before and after a marathon. AT stiffness was determined as the slope of the force–elongation curve between 10 and 80% of maximum voluntary force. AT force–elongation characteristics were measured in an ankle dynamometer using simultaneous motion-capture-assisted ultrasonography. Oxygen consumption and ankle kinematics were also measured on a trea…
Reducing NAFLD-screening time: A comparative study of eight diagnostic methods offering an alternative to ultrasound scans.
2018
Background & Aims: The use of ultrasound scan (US) in non-alcoholic fatty liver disease (NAFLD) screening overloads US waiting lists. We hypothesized and tested a hybrid two-step method, consisting of applying a formula, to exclude subjects at low risk, before US. Methods: The sample included 2970 males and females (937 with NAFLD) diagnosed by US. We selected eight formulas: Fatty Liver Index (FLI), Hepatic Steatosis Index (HIS), body mass index (BMI), waist circumference (WC), Abdominal Volume Index (AVI), waist-to-height ratio (WHtR), waist/height0.5 (WHT.5R) and Body Roundness Index (BRI), and calculated their performance in the two-step method evaluating percentage reduction of the…
Quantification of mitral valve stenosis by three-dimensional transesophageal echocardiography
1996
The aim of this study was the evaluation of the diagnostic potentials of transesophageal 3D- echocardiography in the determination of mitral valve stenosis. 54 patients were investigated by transthoracic and multiplane transesophageal echocardiography. In 41 patients cardiac catheterization was performed. 3D- echocardiographic data acquisition was performed by automatic transducer rotation at 2 degree increments over a span of 180 degrees. The transesophageal probe was linked to an ultrasound unit and to a 3D- workstation capable of ECG- and respiration gated data acquisition, postprocessing and 2D/3D image reconstruction. The mitral valve was visualized in sequential cross-sectional planes…
[Evaluation of three-dimensional endoanal endosonography of perianal fistulas and correlation with surgical findings].
2009
Abstract Objective This study aims to assess the accuracy of three-dimensional endoanal ultrasound (3D-US), two-dimensional ultrasound (2D-US) and physical examination (PE) for the diagnosis of perianal fistulas and correlate the results with intraoperative findings. Materials and methods A prospective, observational study with consecutive inclusion of patients was performed between December 2008 and August 2009. Twenty-nine patients diagnosed with a perianal fistula due to undergo surgery were included. All patients underwent PE, 2D-US and 3D-US, and the results were compared to intraoperative findings. The examinations were repeated with hydrogen peroxide instilled through the external op…
Freehand three-dimensional assessment of left ventricular volumes and ejection fraction with ultrasound contrast agent LK565
2005
Accurate assessment of left ventricular function by determining left ventricular volumes and ejection fraction is important in evaluating the prognoses of patients with heart failure. Two-dimensional (2D) echocardiography suffers from low correlation with reference methods like ventriculography. Three-dimensionally (3D) assessed data have been proved to have better conformity. Endocardial border delineation remains a problem, however, especially in patients with suboptimal recordings. Few data exist on 3D-echocardiographic volumetry with ultrasound contrast agents (UCAs). We evaluated the second-generation UCA LK565 for its boundary-tracing capacities in freehand 3D echocardiography in a ph…