Low-energy extracorporeal shock wave therapy for painful heel: a prospective controlled single-blind study.
1996
The aim of this prospective single-blind pilot study was to explore the pain-alleviating effect of low-energy extracorporeal shock wave therapy (ESWT) in painful heel associated with inferior calcaneal spurs. Thirty patients who suffered from persistent symptoms for more than 12 months qualified for low-energy ESWT and were assigned at random to two groups, real or simulated ESWT. Before beginning the treatment, any other therapy was stopped for a period of 6 weeks. The shock waves were applied by an experimental device allowing exact localization through an integrated fluoroscopy unit. Patients were treated three times at weekly intervals. Each time 1000 impulses of 0.06 mJ/mm2 were given …
Reliability of the bright liver echo pattern in diagnosing steatosis in patients with cryptogenic and HCV-related hypertransaminasaemia.
2008
Aim To evaluate the reliability of the bright liver (BL) echo pattern on ultrasound to detect histological steatosis in chronic cryptogenic hypertransaminasaemia (CCH) and hepatitis C virus (HCV)-related forms of hypertransaminasaemia. Materials and methods One hundred and fifty patients, 54 with CCH and 96 with HCV hypertransaminasaemia (76 genotype 1/2 and 20 genotype 3), were enrolled. Histological steatosis was measured as the percentage of hepatocytes involved. The reliability of the BL sign was estimated using the sensitivity, specificity, positive and negative predictive values. Results Histological steatosis was present in 102/150 patients (68%) divided into 59/96 (62%) in the HCV g…
Value of contrast-enhanced MR angiography and helical CT angiography in chronic thromboembolic pulmonary hypertension.
2003
The aim of this study was to evaluate the diagnostic value of contrast-enhanced MR angiography (ce MRA) and helical CT angiography (CTA) of the pulmonary arteries in the preoperative workup of patients with chronic thromboembolic pulmonary hypertension (CTEPH). The ce MRA and CTA studies of 32 patients were included in this retrospective evaluation. Image quality was scored by two independent blinded observers. Data sets were assessed for number of patent segmental, subsegmental arteries, and number of vascular segments with thrombotic wall thickening, intraluminal webs, and abnormal proximal to distal tapering. Image quality for MRA/CTA was scored excellent in 16 of 16, good in 11 of 14, m…
Neck semispinalis capitis muscle size in sitting and prone positions measured by real-time ultrasonography.
1998
Objective: To examine the reliability of measurements of semispinalis capitis muscle (SECM) cross-sectional area (CSA) in prone and sitting positions, and to compare the muscle size in these two positions. Design: Semispinalis capitis CSA was measured twice a day on two successive days with a real-time ultrasound apparatus. Subjects: Eighteen males (aged 19–34 years) and 28 females (aged 19–34 years) were studied for the reliability test. Seven males and 12 females were randomly selected to compare SECM size in sitting and prone positions. Results: The intraclass correlation coefficient (ICC) for repeatability measurements was r = 0.98 for the two positions. The correlation of the CSA in s…
Role of high-resolution ultrasonography without and with real-time spatial compound imaging in evaluating the injured posterior cruciate ligament: pr…
2009
This study sought to compare high-resolution ultrasonography (HRUS) without and with compound imaging in evaluating the injured posterior cruciate ligament (PCL). Thirteen patients with a magnetic resonance imaging (MRI) diagnosis of PCL lesions (ten acute and three chronic) and 20 healthy controls underwent conventional and compound HRUS performed by the same radiologist who was blinded to the subjects' case-control status. The PCL was scanned in a longitudinal direction in all cases. HRUS images were assessed for PCL thickness by two other radiologists blinded to the number and type of PCL injury. PCLs were classified as normal or injured, and the latter as having acute or chronic injurie…
Magnetic resonance and ultrasound in achilles tendinopathy: Predictive role and response assessment to platelet-rich plasma and adipose-derived strom…
2017
To assess the correlation between magnetic resonance and ultrasound findings and clinical outcome after intratendinous injection of leucocyte-rich platelet-rich plasma or adipose-derived stromal vascular fraction in patients with non-insertional Achilles tendinopathy.Forty-three patients (age: 47.8±5.1, range 29-55) with unilateral or bilateral non-insertional Achilles tendinopathy (58 tendons overall) were randomly assigned to platelet-rich plasma (22 patients, 28 tendons) or adipose-derived stromal vascular fraction (21 patients, 30 tendons) injection group. All patients underwent magnetic resonance (tendon cross-sectional area, signal intensity, maximum anteroposterior thickness were mea…
Finger movements induced by transcranial magnetic stimulation change with hand posture, but not with coil position
1998
We attempted to map the representations of movements in 2 normal subjects by delivering five transcranial magnetic stimuli (TMS) with a focal coil to each of a grid of positions over the primary motor area (M1). Isometric forces were recorded from the contralateral index finger. Maps were made with the hand in a semiflexed “neutral” position, and with the thumb and index finger opposed in a “pincer” grip. The electromyogram (EMG) was monitored to ensure relaxation. The wrist was immobilized. In the neutral position, TMS at almost all positions produced abduction. Flexion was produced in the pincer position. Thus, while sensitive to changes in posture, TMS mapping may not be sensitive to the…
Diagnostic accuracy of current sonographic criteria for the detection of outflow abnormalities in the internal jugular veins
2012
Objectives: This study was aimed at evaluation of the diagnostic value of Doppler sonography for the assessment of abnormalities in the internal jugular veins (IJVs). Method: One hundred and sixteen IJVs were assessed in 58 patients with associated multiple sclerosis. Findings of Doppler sonography were compared with results of the reference test: catheter venography. Results: At least one positive extracranial sonographic criterion suggesting venous abnormality was found in 92.2% of the assessed veins. Yet, sensitivity, specificity, positive and negative predictive values of sonography were low: 93.4%, 12.0%, 79.4% and 33.3% for at least one positive criterion, and for at least two positiv…
Comparison of partial coherence interferometry and ultrasound for anterior segment biometry.
2008
To assess the performance of a partial coherence interferometry (PCI)-based device for the determination of anterior segment biometry.Clinica Centrofama, Cartagena, Murcia, Spain.Central corneal thickness (CCT), anterior chamber depth (ACD), and lens thickness (LT) were measured with the ACMaster PCI anterior segment biometer and an Echoscan US-1800 ultrasound (US) biometer/pachymeter with and without cycloplegia. To determine the precision of the instruments, the same examiner took 30 consecutive CCT, ACD, and LT measurements in a single subject under the same conditions and with and without cycloplegia. The same measurements were performed in additional subjects.Twenty-one eyes (16 subjec…
Image-guided transcranial Doppler sonography for monitoring of vasospasm after subarachnoid hemorrhage.
2016
Transcranial Doppler ultrasound (TCD) is a standard method for bedside vasospasm monitoring after subarachnoid hemorrhage (SAH). Image guidance has previously been shown to reduce intra- and interobserver variability of this method. The aim of the present study was to compare image-guided and conventional TCD in vasospasm monitoring after SAH.418 TCD exams of 24 consecutive SAH patients registered in a database were evaluated. Of these, 130 image-guided exams were identified which had been performed on the same day as conventional Doppler exams. These matched pairs were taken for statistical analysis. Data were tested statistically using the sign test applied at patient level to aggregated …