Search results for "ULTRASOUND"

showing 10 items of 1259 documents

Clinical use of intracoronary imaging. Part 1: guidance and optimization of coronary interventions. An expert consensus document of the European Asso…

2018

This Consensus Document is the first of two reports summarizing the views of an expert panel organized by the European Association of Percutaneous Cardiovascular Interventions (EAPCI) on the clinical use of intracoronary imaging including intravascular ultrasound (IVUS) and optical coherence tomography (OCT). The first document appraises the role of intracoronary imaging to guide percutaneous coronary interventions (PCIs) in clinical practice. Current evidence regarding the impact of intracoronary imaging guidance on cardiovascular outcomes is summarized, and patients or lesions most likely to derive clinical benefit from an imaging-guided intervention are identified. The relevance of the u…

Percutaneousmedicine.medical_treatmentPsychological interventionCoronary Artery Disease030204 cardiovascular system & hematologyCoronary AngiographyGraft OcclusionCoronary artery diseasePostoperative Complications0302 clinical medicineRestenosisIntravascular ultrasoundPercutaneous coronary intervention (PCI)030212 general & internal medicineTomographyUltrasonographyInterventionalmedicine.diagnostic_testGraft Occlusion VascularProsthesis FailureTreatment Outcomesurgical procedures operativeStentsCardiology and Cardiovascular MedicineTomography Optical Coherencemedicine.medical_specialtyConsensus610 Medicine & health2705 Cardiology and Cardiovascular Medicine03 medical and health sciencesPercutaneous Coronary InterventionVascularMedical imagingmedicineHumansMedical physicscardiovascular diseasesUltrasonography InterventionalOptical coherence tomographybusiness.industryPercutaneous coronary interventionStentIntracoronary imagingequipment and suppliesmedicine.disease10020 Clinic for Cardiac SurgeryOptical CoherenceConventional PCIIntravascular ultrasoundbusinessEuroIntervention
researchProduct

Vaginal progesterone decreases preterm birth and neonatal morbidity and mortality in women with a twin gestation and a short cervix: an updated meta‐…

2017

Objective To assess the efficacy of vaginal progesterone for the prevention of preterm birth and neonatal morbidity and mortality in asymptomatic women with a twin gestation and a sonographic short cervix (cervical length ≤ 25 mm) in the mid-trimester. Methods This was an updated systematic review and meta-analysis of individual patient data (IPD) from randomized controlled trials comparing vaginal progesterone with placebo/no treatment in women with a twin gestation and a mid-trimester sonographic cervical length ≤ 25 mm. MEDLINE, EMBASE, POPLINE, CINAHL and LILACS (all from inception to 31 December 2016), the Cochrane Central Register of Controlled Trials, Research Registers of ongoing tr…

Perinatal DeathCervix Uterilaw.inventiontransvaginal ultrasound0302 clinical medicineRandomized controlled trialObstetrics and gynaecologyPregnancylawInfant Mortality030212 general & internal medicineProgesteroneRandomized Controlled Trials as Topic030219 obstetrics & reproductive medicineRadiological and Ultrasound TechnologyObstetricsObstetrics and GynecologyGeneral MedicineMaternal MortalityTreatment OutcomePremature BirthGestationFemalemedicine.symptompreterm deliverymedicine.medical_specialtySystematic ReviewsBirth weightPlaceboAsymptomatic03 medical and health sciencesmedicineHumansRadiology Nuclear Medicine and imagingGynecologyFetusbusiness.industryprematurityInfant NewbornInfantprogestogenscervical lengthAdministration IntravaginalReproductive MedicineprogestinsRelative riskMaternal DeathPregnancy TwinSystematic ReviewbusinessUltrasound in Obstetrics & Gynecology
researchProduct

Photo-acoustic phase-delayed excitation of guided waves in coated bone phantoms

2013

Photo-acoustic skeletal quantitative ultrasound enables assessment of the fundamental flexural guided wave (FFGW) propagating in bone. This mode, consistent with the F(1,1) tube mode can now be measured through a coating of soft tissue. Interference due to ultrasound propagation in the soft tissue surrounding the bone is reduced by using phase-delayed ultrasound excitation. Photo-acoustic phase-delayed excitation was done on five axisymmetric bone phantoms (1-5 mm wall thickness), coated by a 5 mm thick soft-tissue mimicking layer. A fiber head comprising a linear array of four optical fibers (400 μm diameter), illuminated by pulsed laser diodes (905 nm wavelength) generated ultrasound. Thi…

Photoacoustic effectOptical fiberMaterials scienceGuided wave testingta114business.industryUltrasoundPhase (waves)01 natural scienceslaw.invention030507 speech-language pathology & audiology03 medical and health sciencesWavelengthTransducerOpticslaw0103 physical sciences0305 other medical sciencebusiness010301 acousticsGroup delay and phase delay
researchProduct

Investigation of correction factors for non-reference conditions in ion chamber photon dosimetry with Monte-Carlo simulations.

2009

Current dosimetry protocols require geometrical reference conditions for the determination of absorbed dose in external radiotherapy. Whenever these geometrical conditions cannot be maintained the application of additional corrections becomes necessary, in principle. The current DIN6800-2 protocol includes a corresponding factor k(NR), but numerical values are lacking and no definite information about the magnitude of this correction is available yet. This study presents Monte-Carlo based calculations within the 6 MV-X photon field of a linear accelerator for a common used ion chamber (PTW31010) employing the EGSnrc code system. The linear accelerator model was matched to measurements, show…

PhotonMonte Carlo methodBiophysicsRadiation DosageLinear particle acceleratorlaw.inventionIonlawDosimetryHumansScattering RadiationRadiology Nuclear Medicine and imagingPhysicsIonsPhotonsRadiological and Ultrasound TechnologyPhantoms ImagingRadiotherapy Planning Computer-AssistedReproducibility of ResultsWaterParticle acceleratorCharged particleIonization chamberRadiotherapy Intensity-ModulatedAtomic physicsParticle AcceleratorsMonte Carlo MethodAlgorithmsZeitschrift fur medizinische Physik
researchProduct

Characterization of PTW-31015 PinPoint ionization chambers in photon and proton beams

2018

The increased use of complex forms of radiotherapy using small-field photon and proton beams has invoked a growing interest in the use of micro-ionization chambers. In this study, 48 PTW-TM31015 PinPoint-type micro-ionization chambers that are used in the commissioning and patient specific QA of a proton pencil beam scanning (PBS) delivery system have been characterized in proton and high-energy photon beams. In both beam modalities, the entire set of PinPoint chambers was characterized by imaging them, by evaluating their stability using check source measurements, by experimentally determining the ion recombination, polarity effect and by cross calibrating them in terms of absorbed dose to…

PhotonProton030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticscross-calibrationIonizationProton TherapyCalibrationHumansDosimetryRadiology Nuclear Medicine and imagingCobalt RadioisotopesRadiometryPencil-beam scanningpolarity effectPinPoint ionization chamberPhysicsPhotonsion recombinationRadiological and Ultrasound Technologybusiness.industryphoton030220 oncology & carcinogenesisCalibrationPhysics::Accelerator PhysicsProtonLaser beam qualityProtonsbusinessRelative Biological EffectivenessBeam (structure)Physics in Medicine & Biology
researchProduct

A Monte-Carlo based model of the AX-PET demonstrator and its experimental validation

2013

AX-PET is a novel PET detector based on axially oriented crystals and orthogonal wavelength shifter (WLS) strips, both individually read out by silicon photo-multipliers. Its design decouples sensitivity and spatial resolution, by reducing the parallax error due to the layered arrangement of the crystals. Additionally the granularity of AX-PET enhances the capability to track photons within the detector yielding a large fraction of inter-crystal scatter events. These events, if properly processed, can be included in the reconstruction stage further increasing the sensitivity. Its unique features require dedicated Monte-Carlo simulations, enabling the development of the device, interpreting …

PhotonRadiological and Ultrasound TechnologyPhysics::Instrumentation and Detectors010308 nuclear & particles physicsComputer scienceDetectorMonte Carlo methodWavelength shifter01 natural sciences030218 nuclear medicine & medical imagingComputational science03 medical and health sciences0302 clinical medicinePositron-Emission Tomography0103 physical sciencesRadiology Nuclear Medicine and imagingSensitivity (control systems)ParallaxMonte Carlo MethodImage resolutionSimulationPhysics in Medicine and Biology
researchProduct

Collision-kerma conversion between dose-to-tissue and dose-to-water by photon energy-fluence corrections in low-energy brachytherapy

2016

The AAPM TG-43 brachytherapy dosimetry formalism, introduced in 1995, has become a standard for brachytherapy dosimetry worldwide; it implicitly assumes that charged-particle equilibrium (CPE) exists for the determination of absorbed dose to water at different locations, except in the vicinity of the source capsule. Subsequent dosimetry developments, based on Monte Carlo calculations or analytical solutions of transport equations, do not rely on the CPE assumption and determine directly the dose to different tissues. At the time of relating dose to tissue and dose to water, or vice versa, it is usually assumed that the photon fluence in water and in tissues are practically identical, so tha…

Photonmedicine.medical_treatmentBrachytherapyMonte Carlo methodBrachytherapyPhoton energyRadiation DosageFluence030218 nuclear medicine & medical imaging03 medical and health sciencesKerma0302 clinical medicinemedicineHumansDosimetryRadiology Nuclear Medicine and imagingRadiometryPhysicsPhotonsRadiological and Ultrasound Technologybusiness.industryWaterRadiotherapy DosageComputational physics030220 oncology & carcinogenesisAbsorbed doseNuclear medicinebusinessMonte Carlo MethodPhysics in Medicine and Biology
researchProduct

Sensitivity recovery for the AX-PET prototype using inter-crystal scattering events

2014

The development of novel detection devices and systems such as the AX-positron emission tomography (PET) demonstrator often introduce or increase the measurement of atypical coincidence events such as inter-crystal scattering (ICS). In more standard systems, ICS events often go undetected and the small measured fraction may be ignored. As the measured quantity of such events in the data increases, so too does the importance of considering them during image reconstruction. Generally, treatment of ICS events will attempt to determine which of the possible candidate lines of response (LoRs) correctly determine the annihilation photon trajectory. However, methods of assessment often have low su…

PhotonsRadiological and Ultrasound TechnologyPhantoms ImagingComputer scienceScatteringIterative reconstructionSensitivity and SpecificityImaging phantomSignal-to-noise ratioPositron-Emission TomographyImage Processing Computer-AssistedScattering RadiationRadiology Nuclear Medicine and imagingTomographySensitivity (control systems)AlgorithmAlgorithmsSimulationPhysics in Medicine and Biology
researchProduct

Picosecond time-resolved study on the nature of high-energy-state quenching in isolated pea thylakoids different localization of zeaxanthin dependent…

1996

Abstract The influence of the transthylakoid proton gradient on the kinetics of picosecond fluorescence decay was examined using isolated pea thylakoids having high or low zeaxanthin contents. Fluorescence lifetime measurements were performed with open (Fo) and closed (Fm) PS II reaction centers. Zeaxanthin formation in membrane energized isolated thylakoids led to a marked decrease of the average fluorescence lifetime at both Fm and Fo. In contrast, when zeaxanthin synthesis was blocked by the inhibitor DTT, the fluorescence lifetime decrease was less pronounced in the Fm state and totally missing in the Fo state. Samples containing the uncoupler ammonium chloride did not exhinit any zeaxa…

Photosynthetic reaction centreRadiationQuenching (fluorescence)Radiological and Ultrasound TechnologyPhotosystem IIChemistryBiophysicsfood and beveragesPhotochemistryFluorescenceeye diseasesZeaxanthinchemistry.chemical_compoundReaction rate constantThylakoidRadiology Nuclear Medicine and imagingElectrochemical gradientJournal of Photochemistry and Photobiology B: Biology
researchProduct

An Ultrasonic Lens Design Based on Prefractal Structures

2016

The improvement in focusing capabilities of a set of annular scatterers arranged in a fractal geometry is theoretically quantified in this work by means of the finite element method (FEM). Two different arrangements of rigid rings in water are used in the analysis. Thus, both a Fresnel ultrasonic lens and an arrangement of rigid rings based on Cantor prefractals are analyzed. Results show that the focusing capacity of the modified fractal lens is better than the Fresnel lens. This new lens is believed to have potential applications for ultrasonic imaging and medical ultrasound fields.

Physics and Astronomy (miscellaneous)General MathematicsPhysics::Optics02 engineering and technology01 natural scienceslaw.inventionFractalOpticsCantor prefractalslaw0103 physical sciencesComputer Science (miscellaneous)Medical ultrasoundMathematics010302 applied physicsbusiness.industrylcsh:MathematicsFresnel lensUltrasonic lens021001 nanoscience & nanotechnologylcsh:QA1-939Finite element methodUltrasonic imagingLens (optics)Chemistry (miscellaneous)FISICA APLICADAUltrasonic sensorSound focusing0210 nano-technologybusinessMATEMATICA APLICADA
researchProduct