Search results for "Ultra"
showing 10 items of 4451 documents
Rail track field testing using laser/air hybrid ultrasonic technique
2003
Nondestructive testing methods used for the testing of rail in tracks worldwide can be limited by discontinuity location or orientation within the rail. Vertical split head and rail base cracks are among those types of discontinuities that are difficult to detect, which in some cases may result in a reail failure in service. A noncontact and remote hybrid ultrasonic technique has been developed by combining laser generation with air coupled detection of ultrasonic signals in rails. The test apparatus mounts on a railroad pushcart and tests are performed in motion with all components kept above the running surface of the rail track. Tracks have been tested for vertical split head and rail ba…
Experimental signatures of extreme optical fluctuations in lumped Raman fiber amplifiers
2012
International audience; In this work, we experimentally investigate several temporal and spectral methods to highlight extreme fluctuations which can develop during the Raman amplification of an ultrashort pulse train. Forward and backward pumping schemes are compared to dual pass configurations.
A range of pulses commonly used for human transcranial ultrasound stimulation are clearly audible.
2021
Laser driven parametric amplification in the xuv and soft-x-ray spectral range
2011
We present the first experimental realization of a new x-ray laser scheme based on strong-field parametric amplification of high-order harmonic radiation. With a simple semi-classical model, we can identify the most important experimental parameters, the spectral range and the small signal gain in gases. Using a single amplifier stage a small signal gain of 8000 has been obtained in Argon for the spectral range of 40-50 eV, using 350 fs, 7 mJ pulses at 1.05 µm. In Helium, we observed a small signal gain of 280 around 300 eV using 6 fs, 1.5 mJ pulses at 800 nm.
Self-trapped exciton in Li2GeO3
1997
Abstract Self-trapped excitons (STE) are discovered in Li2GeO3 crystal. The PL band at 2.7 eV with a strong Stoke's shift is excited in the intrinsic absorption range of Li2GeO3 crystal, in which the optical gap is situated at 6 eV. The activation energy of the STE luminescence thermal quenching is not monoenergetic and is situated in the range 40–100 meV. The luminescence is strongly polarized. The decay kinetics can be characterized by τ = 0.9 ms at 45 K. At 5 K it can be approximated by fast (0.6 ms) and slow (4–2.5 ms) components. Decay kinetics is determined by triplet state of STE splits in zero magnetic field. Two different excited triplet states (centers) have the average ODMR param…
Two-color ionization of hydrogen by short intense pulses
2010
Photoelectron energy spectra resulting by the interaction of hydrogen with two short pulses having carrier frequencies, respectively, in the range of the infrared and XUV regions have been calculated. The effects of the pulse duration and timing of the X-ray pulse on the photoelectron energy spectra are discussed. Analysis of the spectra obtained for very long pulses show that certain features may be explained in terms of quantum interferences in the time domain. It is found that, depending on the duration of the X-ray pulse, ripples in the energy spectra separated by the infrared photon energy may appear. Moreover, the temporal shape of the low frequency radiation field may be inferred by …
Tuning the high-order harmonic lines of a Nd:Glass laser for soft x-ray laser seeding
2010
Taking advantage of the non-adiabatic blue-shift of high-order harmonics generated by a fixed frequency Nd:Glass laser system, we are able to report more than 50 % coverage of the XUV spectral range between 18 nm and 35 nm. The generated harmonic lines are capable of seeding Ni-like Y, Zr and Mo soft x-ray lasers and others.
Luminescence of γ-radiation-induced defects in α-quartz
2004
Optical transitions associated with γ-radiation-induced defects in crystalline α-quartz were investigated by photoluminescence excited by both pulsed synchrotron radiation and steady-state light. After a 10 MGy γ-dose we observed two emissions at 4.9 eV (ultraviolet band) and 2.7 eV (blue band) excitable in the range of the induced absorption band at 7.6 eV. These two luminescence bands show a different temperature dependence: the ultraviolet band becomes bright below 80 K; the blue band increases below 180 K, but drops down below 80 K. Both emissions decay in a timescale of a few ns under pulsed excitation, however the blue band could also be observed in slow recombination processes and it…
Stable and long-time operation of a soft x-ray laser for user applications experiments
2011
LASERIX is a high-power laser facility leading to High-repetition-rate XUV laser pumped by Titanium:Sapphire laser. The aim of this laser facility is to offer Soft XRLs in the 30-7 nm range and auxiliary IR beam that could also be used to produce synchronized XUV sources. This experimental configuration highly enhances the scientific opportunities of the facility, giving thus the opportunity to realize both X-ray laser experiments and more generally pump/probe experiments, mixing IR and XUV sources. In this contribution, the main results concerning both the development of XUV sources(X-Ray lasers and HHG sources) and their use for applications are presented.
Low-Rank Tucker-2 Model for Multi-Subject fMRI Data Decomposition with Spatial Sparsity Constraint
2022
Tucker decomposition can provide an intuitive summary to understand brain function by decomposing multi-subject fMRI data into a core tensor and multiple factor matrices, and was mostly used to extract functional connectivity patterns across time/subjects using orthogonality constraints. However, these algorithms are unsuitable for extracting common spatial and temporal patterns across subjects due to distinct characteristics such as high-level noise. Motivated by a successful application of Tucker decomposition to image denoising and the intrinsic sparsity of spatial activations in fMRI, we propose a low-rank Tucker-2 model with spatial sparsity constraint to analyze multi-subject fMRI dat…