Search results for "Ultrafiltration"

showing 10 items of 68 documents

An automated on-line multidimensional HPLC system for protein and peptide mapping with integrated sample preparation.

2002

A comprehensive on-line two-dimensional 2D-HPLC system with integrated sample preparation was developed for the analysis of proteins and peptides with a molecular weight below 20 kDa. The system setup provided fast separations and high resolving power and is considered to be a complementary technique to 2D gel electrophoresis in proteomics. The on-line system reproducibly resolved approximately 1000 peaks within the total analysis time of 96 min and avoided sample losses by off-line sample handling. The low-molecular-weight target analytes were separated from the matrix using novel silica-based restricted access materials (RAM) with ion exchange functionalities. The size-selective sample fr…

ChromatographyIon exchangeChemistryIon chromatographyAnalytical chemistryProteinsUltrafiltrationFibroblastsMass spectrometryChromatography Ion ExchangeHigh-performance liquid chromatographyOnline SystemsPeptide MappingAnalytical ChemistryCell LineMatrix (chemical analysis)Matrix-assisted laser desorption/ionizationTwo-dimensional chromatographySpectrometry Mass Matrix-Assisted Laser Desorption-IonizationHumansSample preparationElectrophoresis Polyacrylamide GelChromatography High Pressure LiquidAnalytical chemistry
researchProduct

Peptides analysis in blood plasma using on-line system of supported liquid membrane and high-performance liquid chromatography

2005

The potential of using supported liquid membrane (SLM) technique, combined with reversed-phase high-performance liquid chromatography (RP-HPLC) has been investigated for the determination of peptides in human blood plasma. The peptides studied were (DL)Leu(DL)Phe, MetLeuPhe, GlyLeuTyr and ValGluProlleProTyr. The carrier (Aliquat 336) was incorporated in membrane phase in order to facilitate the transport of investigated peptides. After extraction, the analyte-enriched acceptor phase was directly injected into an HPLC system for analysis. With SLM, high selectivity and efficiency were achieved for extraction of peptides in aqueous solutions. Lower extraction efficiency was obtained in plasma…

Chromatographyaliquat 336Extraction (chemistry)Analytical chemistryUltrafiltrationReversed-phase chromatographyAliquat 336BiochemistryHigh-performance liquid chromatographyAnalytical ChemistryStandard curvechemistry.chemical_compoundMembranechemistrypeptidesEnvironmental ChemistrySample preparationsupported liquid membraneHPLCSpectroscopyblood plasmaAnalytica Chimica Acta
researchProduct

Enzymatic cleaning of inorganic ultrafiltration membranes used for whey protein fractionation

2003

Abstract The aim of this work was to study the cleaning of inorganic membranes fouled by whey protein solutions using proteolytic enzymes. Tami ® 150+4T membranes (Tami Industries, S.A., 26110 Nyons, France) of 400 kg/mol molecular weight cut-off (MWCO) and a ZrO 2 filtering layer were selected to carry out the tests and Maxatase ® XL (Genencor International, 2333 CN Leiden, The Netherlands) and P3-Ultrasil ® 62 (Henkel Iberica, S.A., 08025 Barcelona, Spain) were investigated as cleaning agents. Cleaning efficiency was observed to be a function of the operating conditions. The operating conditions studied were the pH of the cleaning solution, the enzymatic agent concentration and cleaning t…

Cleaning agentWhey proteinChromatographyChemistryUltrafiltrationProteolytic enzymesFiltration and SeparationFractionationPermeationBiochemistryHydrolysisMembraneGeneral Materials SciencePhysical and Theoretical ChemistryJournal of Membrane Science
researchProduct

Evaluation of enantioselective binding of fluoxetine to human serum albumin by ultrafiltration and CE - Experimental design and quality considerations

2012

Several pharmacokinetic processes are affected by enantioselectivity (ES). At the level of distribution, protein binding (PB) is one of the most important. The enantioselective binding of fluoxetine (FLX) to HSA has been evaluated in this work by ultrafiltration of FLX–HSA mixtures and chiral analysis of unbound fractions by EKC-CD. PB, affinity constants (K) and ES were obtained for both enantiomers of FLX. In order to improve the consistency of the estimations, the evaluation of affinity constants of each enantiomer was performed using two designs, one keeping constant the total concentration of protein and varying the total concentration of the enantiomers, and the other in the opposite …

Clinical BiochemistrySerum albuminUltrafiltrationUltrafiltrationStereoisomerismBiochemistryAnalytical ChemistryFluoxetinemedicineHumansBinding siteSerum AlbuminChromatographybiologyChemistryEnantioselective synthesisElectrophoresis CapillaryReproducibility of ResultsStereoisomerismHuman serum albuminModel validityNonlinear Dynamicsbiology.proteinEnantiomerAlgorithmsProtein Bindingmedicine.drugELECTROPHORESIS
researchProduct

Evaluation of enantioselective binding of propanocaine to human serum albumin by ultrafiltration and electrokinetic chromatography under intermediate…

2011

Abstract Stereoselectivity in protein binding can have a significant effect on the pharmacokinetic and pharmacodynamic properties of chiral drugs. In this paper, the enantioselective binding of propanocaine (PRO) enantiomers to human serum albumin (HSA), the most relevant plasmatic protein in view of stereoselectivity, has been evaluated by incubation and ultrafiltration of racemic PRO–HSA mixtures and chiral analysis of the bound and unbound fractions by electrokinetic chromatography using HSA as chiral selector. Experimental conditions for the separation of PRO enantiomers using HSA as chiral selector and electrokinetic chromatography have been optimised. Affinity constants and protein bi…

Clinical BiochemistryUltrafiltrationUltrafiltrationPlasma protein bindingBiochemistryBenzoatesAnalytical ChemistryIn vivomedicineHumansSerum AlbuminChromatography Micellar Electrokinetic CapillaryChromatographyPropylaminesElutionChemistryEnantioselective synthesisReproducibility of ResultsStereoisomerismCell BiologyGeneral MedicineHydrogen-Ion ConcentrationHuman serum albuminLinear ModelsStereoselectivityEnantiomermedicine.drugProtein BindingJournal of chromatography. B, Analytical technologies in the biomedical and life sciences
researchProduct

Recovering coronavirus from large volumes of water

2021

The need for monitoring tools to better control the ongoing coronavirus disease (COVID-19) pandemic is extremely urgent and the contamination of water resources by excreted viral particles poses alarming questions to be answered. As a first step to overcome technical limitations in monitoring SARS-CoV-2 along the water cycle, we assessed the analytical performance of a dead end hollow fiber ultrafiltration coupled to different options for secondary concentrations to concentrate viral particles from large volume of spiked tap water, seawater and surface water together with two quantitative RT-qPCR detection kits. Spiking the porcine epidemic diarrhea virus (PEDV), an enveloped virus surrogat…

ConcentrationEnvironmental Engineering010504 meteorology & atmospheric sciencesSwineUltrafiltration010501 environmental sciencesmedicine.disease_cause01 natural sciencesArticleTap waterAigües residualsMengovirusmedicineAnimalsHumansEnvironmental ChemistryTap waterSeawaterWaste Management and Disposal0105 earth and related environmental sciencesCoronavirusChromatographybiologySewageSARS-CoV-2ChemistryRT-qPCRWaterCOVID-19Surface waterContaminationbiology.organism_classificationPollutionCoronavirusSeawaterCoronavirus InfectionsPorcine epidemic diarrhea virusSurface water
researchProduct

Transthoracic electrical impedance during extracorporeal hemodialysis in acute respiratory failure ("Shocked Lung syndrome").

1980

The alteration (delta Z0) of transthoracic electrical impedance (TEI) during extracorporeal hemodialysis (EHD) was investigated in two Groups of patients with acute renal and acute respiratory failure, that differed with respect to the severity of respiratory insufficiency. Group I had moderate respiratory failure (FiO2 0.31 +/- 0.10, PaO2 84 +/- 14 mmHg), and Group II had severe respiratory failure (FiO2 0.75 +/- 0.17, PaO2 77 +/- 14 mmHg). There was a significant correlation between increase in TEI (delta Z0) and decrease in body weight (delta BW) in each individual patient, but the slope of regression lines was remarkably flattened in Group II. In Group I, delta TEI was 1.9 +/- 0.9 omega…

DeltaAdultMalemedicine.medical_specialtyRespiratory TherapyPostureUltrafiltrationPulmonary EdemaHematocritCritical Care and Intensive Care MedicineCardiography ImpedanceRenal DialysisInternal medicinemedicinePlethysmographHumansAcute respiratory failurePlethysmography ImpedanceRespiratory systemAgedLungmedicine.diagnostic_testbusiness.industryBody WeightAcute Kidney InjuryMiddle AgedExtracorporeal hemodialysismedicine.anatomical_structureRespiratory failureHematocritCardiologyFemalebusinessRespiratory InsufficiencyIntensive care medicine
researchProduct

Characterization of basic drug–human serum protein interactions by capillary electrophoresis

2006

Drug-protein interactions are determining factors in the therapeutic, pharmacodynamic and toxicological drug properties. The affinity of drugs towards plasmatic proteins is apparently well established in bibliography. Albumin (HSA) especially binds neutral and negatively charged compounds; alpha(1)-acid glycoprotein (AGP) binds many cationic drugs, lipoproteins bind to nonionic and lipophilic drugs and some anionic drugs while globulins interact inappreciably with the majority of drugs. In this paper, the characterization of the interaction between cationic drugs, beta-blockers and phenotiazines towards HSA, AGP, and both HSA + AGP mixtures of proteins under physiological conditions by CE-f…

DrugGlobulinmedia_common.quotation_subjectAdrenergic beta-AntagonistsClinical BiochemistryThiazinesUltrafiltrationPlasma protein bindingBiochemistryAnalytical ChemistryCapillary electrophoresisPhenothiazinesmedicineHumansLabetalolSerum Albuminmedia_commonchemistry.chemical_classificationbiologyAlbuminElectrophoresis CapillaryBlood ProteinsOrosomucoidHuman serum albuminchemistryBiochemistryPindololbiology.proteinGlycoproteinDrug metabolismProtein Bindingmedicine.drugELECTROPHORESIS
researchProduct

An acid extract from dissociation medium of sea urchin embryos, induces mesenchyme differentiation

1992

Abstract When material extracted by 1 M acetic acid from the dissociation medium of sea urchin embryos is added at low concentrations to isolated primary mesenchyme cells, it induces skeletogenesis. The same material added to dissociated blastula cells, or to embryos at the blastula stage, stimulates skeleton formation and pigment cell differentiation. On dissociated cells, it also increases cell reaggregation, thymidine incorporation and survival. On embryos, it induces exogastrulation and appearence of extraembryonic pigment cells. The activity of the extract is resistant to raised temperatures and partially to tryptic digestion but is abolished by trypsin treatment followed by heating. T…

Embryo Nonmammaliananimal structuresMesenchymeCellular differentiationUltrafiltrationBiologyMorulaPigment cell differentiationMesodermbiology.animalBotanymedicineAnimalsGrowth SubstancesSea urchinConnective Tissue CellsEmbryonic InductionTissue ExtractsEmbryogenesisCell DifferentiationEmbryoGastrulaCell BiologyHydrogen-Ion ConcentrationBlastulaTrypsinCell biologyBlastocystmedicine.anatomical_structureConnective TissueSea Urchinsembryonic structuresChromatography Liquidmedicine.drugCell Biology International Reports
researchProduct

Instrumentation, control, and automation for submerged anaerobic membrane bioreactors

2015

A submerged anaerobic membrane bioreactor (AnMBR) demonstration plant with two commercial hollow-fibre ultrafiltration systems (PURON® , Koch Membrane Systems, PUR-PSH31) was designed and operated for urban wastewater treatment. An instrumentation, control, and automation (ICA) system was designed and implemented for proper process performance. Several single-input-single-output (SISO) feedback control loops based on conventional on off and PID algorithms were implemented to control the following operating variables: flow-rates (influent, permeate, sludge recycling and wasting, and recycled biogas through both reactor and membrane tanks), sludge wasting volume, temperature, transmembrane pr…

EngineeringINGENIERIA HIDRAULICAAutomatic controlUltrafiltrationPID controllerUltrafiltrationIndustrial-scale membranesFeedbackWater PurificationBacteria AnaerobicBioreactorsBiogasBioreactorEnvironmental ChemistryAnaerobiosisSubmerged anaerobic membrane bioreactor (AnMBR)Waste Management and DisposalInstrumentationSpargingTECNOLOGIA DEL MEDIO AMBIENTEWater Science and TechnologyWaste managementSewagebusiness.industryMembranes ArtificialGeneral MedicineEquipment DesignRoboticsEquipment Failure AnalysisWastewaterUrban wastewater treatmentSewage treatmentbusinessControl and automation (ICA)Demonstration plant
researchProduct