Ultrasound hyperthermia induces apoptosis in head and neck squamous cell carcinoma: an in vitro study
2016
Background Hyperthermia is considered an efficient complement in the treatment of head and neck squamous cell carcinoma (HNSCC). Hyperthermia induces cell apoptosis in a temperature- and time-dependent manner. However, the molecular mechanism of hyperthermia remains unclear. The aim of this study was to investigate the mechanism of apoptosis induced by ultrasound hyperthermia in HNSCC cell lines HN-30 and HN-13. Material and Methods We examined the dynamic changes of early apoptosis and secondary necrosis in HN-30 and HN-13 cells treated by hyperthermia at 42°C for 10 min. We further examined mitochondrial membrane potential in vitro by ultrasound hyperthermia for different heating temperat…
Therapeutic Application of 20-kHz Transcranial Ultrasound in an Embolic Middle Cerebral Artery Occlusion Model in Rats
2007
Background and Purpose— Therapeutic application of diagnostic ultrasound has been shown to improve recanalization rates in patients with acute cerebral vessel occlusion. There is experimental evidence that low-frequency ultrasound may be superior. This study was designed to evaluate the therapeutic efficacy and safety of low-frequency ultrasound in an embolic middle cerebral artery occlusion model in rats. A parameter setting was used that had not previously shown any side effects and interactions with healthy rat brain tissue. Methods— Male Wistar rats were submitted to middle cerebral artery clot embolism and transcranial treatment with 20-kHz continuous-wave ultrasound (0.2 W/cm 2 ), ei…
In vivo effects of an Er:YAG Laser, an ultrasonic system and scaling and root planing on the biocompatibility of periodontally diseased root surfaces…
2003
Background and Objectives The aim of the present study was to investigate the in vivo effects of an Er:YAG laser (ERL), an ultrasonic system and scaling and root planing (SRP) on the biocompatibility of periodontally diseased root surfaces in cultures of human periodontal ligament fibroblasts (PDL). Study Design/Materials and Methods Forty single rooted teeth, considered for extraction due to severe periodontal destruction, have been randomly assigned to the following groups: (1) ERL at 160 mJ/pulse and 10 Hz, or (2) Vector® ultrasonic system (VUS), or (3) SRP using hand instruments, or (4) untreated control (C). Immediately after instrumentation, all test and control teeth were extracted a…
Low-Frequency Therapeutic Ultrasound with Varied Duty Cycle: Effects on the Ischemic Brain and the Inner Ear
2009
Sonothrombolysis is a promising modality for acute stroke treatment. In vitro data suggest a duty cycle dependence of sonothrombolytic efficacy of low-frequency applications. The aim of our study was to examine its impact on safety issues in a rat model of middle cerebral artery occlusion. Rats were exposed to transcranial 60-kHz ultrasound with varied duty cycles. To determine effects on the inner ear, the acoustic threshold was determined in additional healthy animals (acoustic evoked potentials). A short duty cycle (20%) resulted in significant adverse effects (ischemic volume, hemorrhage, functional outcome), which was not observed in longer duty cycle (80%). Continuous-wave insonation …
Detrimental Effects of 60 kHz Sonothrombolysis in Rats with Middle Cerebral Artery Occlusion
2008
Recent studies have raised concerns about the safety of low frequency ultrasound in transcranial therapeutic application in cerebral ischemia. This study was designed to evaluate safety aspects and potential deleterious effects of low frequency, 60 kHz ultrasound in treatment of experimental middle cerebral artery occlusion (MCAO) in rats. Forty-five male Wistar rats were submitted to either temporary (90 min; groups I and II) or permanent MCAO (groups III and IV) using the suture technique. All animals received recombinant tissue plasminogen activator (rt-PA) starting 90 min after the beginning of occlusion. Groups I and III were additionally treated with 60 kHz ultrasound (time average ac…
Role of high-resolution ultrasound in guiding treatment of idiopathic plantar fasciitis with minimally invasive techiniques
2007
The aim of this study was to assess the reliability of peri-fascial oedema as a sonographic criterion for selecting the most appropriate treatment (ultrasound-guided corticosteroid injection or ultrasound-guided extracorporeal shock wave therapy) of idiopathic plantar fasciitis (IPF).Sixty-four patients with a clinical diagnosis of unilateral refractory IPF, treated conservatively for at least 8 weeks, were studied with high-resolution ultrasound (HRUS). Pain intensity was evaluated with a visual analogue scale (VAS). HRUS was used to confirm IPF and identify the presence of peri-fascial oedema. Patients with an HRUS diagnosis of IPF were grouped according to the presence (A) or absence (B)…
Blood-brain barrier disruption by low-frequency ultrasound.
2006
Background and Purpose— A recent study showed a dramatic increase in cerebral hemorrhage comprising atypical locations with low-frequency ultrasound–mediated recombinant tissue plasminogen activator–thrombolysis in humans. Here, we provide a possible explanation for this phenomenon by a side effect observed in a study using the similar ultrasound device. Methods— The study was originally undertaken to investigate by transcranial Doppler sonography, positron emission tomography and perfusion MRI whether transcranial application of wide-field low-frequency ultrasound (300 kHz) improves cerebral hemodynamics in patients with cerebral small vessel disease. Results— Showing no clear positive ef…
Effects of various hygiene procedures on the surface characteristics of titanium abutments.
1996
The use of cleaning instruments on titanium implants may cause undesired surface alterations. In a qualitative and quantitative assessment of these alterations, 5 titanium implant abutments were treated with a steel curet, a prototype pure titanium curet, an air abrasive polishing system, and an ultrasonic system. Custom-made polymer templates, used to secure the curet to a vertical guide bar and a spring scale to maintain a constant instrument pressure, guaranteed a standardized procedure and reproducible results. The ultrasonic and the air abrasive polishing method were also standardized. Evaluation by scanning electron microscopy (SEM) revealed surface alterations for all instruments and…
Histologic Evaluation of Human Intrabony Defects Following Non-Surgical Periodontal Therapy With and Without Application of an Enamel Matrix Protein …
2003
Background: Surgical periodontal treatment with enamel matrix protein derivative (EMD) has been shown to promote periodontal regeneration. However, it is not known whether nonsurgical periodontal therapy with additional subgingival application of EMD may also enhance periodontal regeneration. The purpose of this study was to clinically and histologically evaluate healing of human intrabony defects following non-surgical periodontal treatment with and without application of EMD. Methods: Sixteen patients, each of whom displayed one advanced intrabony defect around teeth or roots scheduled for extraction, were included in the study. The defects were treated as follows: 1) scaling and root pla…
Evaluation of apical preparations performed with ultrasonic diamond and stainless steel tips at different intensities using a scanning electron micro…
2011
Objective: The objective of our study is to analyse (with the help of scanning electron microscopes) the quality of the dental root surface and the appearance of dental cracks after performing apical preparations using two diffe-rent types of ultrasonic tips. Study design: We used 32 single-rooted teeth that underwent a root canal and apical resection. Afterwards, the teeth were divided into 4 groups of 8 teeth each, with preparations of the apical cavities in the following manner: Group 1: stainless steel ultrasonic tip at 33KHz. Group 2: stainless steel ultrasonic tip at 30KHz. Group 3: diamond ultrasonic tip at 30KHz. Group 4: diamond ultrasonic tip at 33 KHz. The quality of the root sur…