Search results for "Ultrasonic therapy"

showing 10 items of 27 documents

Ultrasound hyperthermia induces apoptosis in head and neck squamous cell carcinoma: an in vitro study

2016

Background Hyperthermia is considered an efficient complement in the treatment of head and neck squamous cell carcinoma (HNSCC). Hyperthermia induces cell apoptosis in a temperature- and time-dependent manner. However, the molecular mechanism of hyperthermia remains unclear. The aim of this study was to investigate the mechanism of apoptosis induced by ultrasound hyperthermia in HNSCC cell lines HN-30 and HN-13. Material and Methods We examined the dynamic changes of early apoptosis and secondary necrosis in HN-30 and HN-13 cells treated by hyperthermia at 42°C for 10 min. We further examined mitochondrial membrane potential in vitro by ultrasound hyperthermia for different heating temperat…

HyperthermiaPathologymedicine.medical_specialtyNecrosisUltrasonic TherapyApoptosis030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineTumor Cells CulturedmedicineCarcinomaHumansGeneral DentistryOral Medicine and PathologySquamous Cell Carcinoma of Head and NeckChemistrybusiness.industryResearchUltrasoundHyperthermia Induced:CIENCIAS MÉDICAS [UNESCO]medicine.diseaseHead and neck squamous-cell carcinomaIn vitroOtorhinolaryngologyHead and Neck NeoplasmsApoptosisCell culture030220 oncology & carcinogenesisUNESCO::CIENCIAS MÉDICASCarcinoma Squamous CellCancer researchSurgerymedicine.symptombusinessMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Therapeutic Application of 20-kHz Transcranial Ultrasound in an Embolic Middle Cerebral Artery Occlusion Model in Rats

2007

Background and Purpose— Therapeutic application of diagnostic ultrasound has been shown to improve recanalization rates in patients with acute cerebral vessel occlusion. There is experimental evidence that low-frequency ultrasound may be superior. This study was designed to evaluate the therapeutic efficacy and safety of low-frequency ultrasound in an embolic middle cerebral artery occlusion model in rats. A parameter setting was used that had not previously shown any side effects and interactions with healthy rat brain tissue. Methods— Male Wistar rats were submitted to middle cerebral artery clot embolism and transcranial treatment with 20-kHz continuous-wave ultrasound (0.2 W/cm 2 ), ei…

MaleAdvanced and Specialized Nursingbusiness.industryUltrasonic Therapymedicine.medical_treatmentUltrasoundInfarction Middle Cerebral ArteryThrombolysismedicine.diseaseRatsTranscranial DopplerDisease Models AnimalEmbolismmedicine.arteryAnesthesiaMiddle cerebral arteryOcclusionmedicineAnimalsNeurology (clinical)Rats WistarCardiology and Cardiovascular MedicinebusinessPlasminogen activatorStrokeStroke
researchProduct

In vivo effects of an Er:YAG Laser, an ultrasonic system and scaling and root planing on the biocompatibility of periodontally diseased root surfaces…

2003

Background and Objectives The aim of the present study was to investigate the in vivo effects of an Er:YAG laser (ERL), an ultrasonic system and scaling and root planing (SRP) on the biocompatibility of periodontally diseased root surfaces in cultures of human periodontal ligament fibroblasts (PDL). Study Design/Materials and Methods Forty single rooted teeth, considered for extraction due to severe periodontal destruction, have been randomly assigned to the following groups: (1) ERL at 160 mJ/pulse and 10 Hz, or (2) Vector® ultrasonic system (VUS), or (3) SRP using hand instruments, or (4) untreated control (C). Immediately after instrumentation, all test and control teeth were extracted a…

MaleBiocompatibilityPeriodontal LigamentUltrasonic TherapyDentistryDermatologyCell morphologyScaling and root planingIn vivoUntreated controlCell AdhesionmedicineHumansPeriodontal fiberTooth RootPeriodontitisFibroblastCells CulturedAgedMicroscopyChemistrybusiness.industryFibroblastsMiddle Agedmedicine.anatomical_structureDental ScalingFemaleSurgeryLaser TherapybusinessEr:YAG laserLasers in Surgery and Medicine
researchProduct

Low-Frequency Therapeutic Ultrasound with Varied Duty Cycle: Effects on the Ischemic Brain and the Inner Ear

2009

Sonothrombolysis is a promising modality for acute stroke treatment. In vitro data suggest a duty cycle dependence of sonothrombolytic efficacy of low-frequency applications. The aim of our study was to examine its impact on safety issues in a rat model of middle cerebral artery occlusion. Rats were exposed to transcranial 60-kHz ultrasound with varied duty cycles. To determine effects on the inner ear, the acoustic threshold was determined in additional healthy animals (acoustic evoked potentials). A short duty cycle (20%) resulted in significant adverse effects (ischemic volume, hemorrhage, functional outcome), which was not observed in longer duty cycle (80%). Continuous-wave insonation …

MaleSubarachnoid hemorrhageAcoustics and UltrasonicsUltrasonic Therapymedicine.medical_treatmentBiophysicsIschemiaInfarctionBrain Ischemiaotorhinolaryngologic diseasesAnimalsMedicineRadiology Nuclear Medicine and imagingInner earRats WistarHearing DisordersStrokeRadiological and Ultrasound TechnologyTherapeutic ultrasoundbusiness.industryUltrasoundAuditory ThresholdInfarction Middle Cerebral Arterymedicine.diseaseRatsmedicine.anatomical_structureDuty cycleEar InnerAnesthesiabusinessUltrasound in Medicine & Biology
researchProduct

Detrimental Effects of 60 kHz Sonothrombolysis in Rats with Middle Cerebral Artery Occlusion

2008

Recent studies have raised concerns about the safety of low frequency ultrasound in transcranial therapeutic application in cerebral ischemia. This study was designed to evaluate safety aspects and potential deleterious effects of low frequency, 60 kHz ultrasound in treatment of experimental middle cerebral artery occlusion (MCAO) in rats. Forty-five male Wistar rats were submitted to either temporary (90 min; groups I and II) or permanent MCAO (groups III and IV) using the suture technique. All animals received recombinant tissue plasminogen activator (rt-PA) starting 90 min after the beginning of occlusion. Groups I and III were additionally treated with 60 kHz ultrasound (time average ac…

MaleSubarachnoid hemorrhageAcoustics and UltrasonicsUltrasonic Therapymedicine.medical_treatmentBiophysicsIschemiaOcclusionmedicineAnimalsThrombolytic TherapyRadiology Nuclear Medicine and imagingRats WistarHearing DisordersStrokeCerebral HemorrhageRadiological and Ultrasound TechnologyTherapeutic ultrasoundmedicine.diagnostic_testbusiness.industryUltrasoundTemperatureInfarction Middle Cerebral ArteryMagnetic resonance imagingSubarachnoid Hemorrhagemedicine.diseaseCombined Modality TherapyMagnetic Resonance ImagingRatsTreatment OutcomeAnesthesiabusinessPerfusionUltrasound in Medicine & Biology
researchProduct

Role of high-resolution ultrasound in guiding treatment of idiopathic plantar fasciitis with minimally invasive techiniques

2007

The aim of this study was to assess the reliability of peri-fascial oedema as a sonographic criterion for selecting the most appropriate treatment (ultrasound-guided corticosteroid injection or ultrasound-guided extracorporeal shock wave therapy) of idiopathic plantar fasciitis (IPF).Sixty-four patients with a clinical diagnosis of unilateral refractory IPF, treated conservatively for at least 8 weeks, were studied with high-resolution ultrasound (HRUS). Pain intensity was evaluated with a visual analogue scale (VAS). HRUS was used to confirm IPF and identify the presence of peri-fascial oedema. Patients with an HRUS diagnosis of IPF were grouped according to the presence (A) or absence (B)…

Malemedicine.medical_specialtyExtracorporeal shock wave therapyUltrasonic TherapyPlantar fasciitisInjections IntralesionalHigh-Energy Shock WavesmedicineHumansRadiology Nuclear Medicine and imagingFasciitisGlucocorticoidsSicilyUltrasonography InterventionalPain MeasurementNeuroradiologymedicine.diagnostic_testbusiness.industryUltrasoundHigh resolution ultrasoundInterventional radiologyGeneral MedicineMiddle Agedmedicine.diseaseSurgeryTreatment OutcomeFasciitis PlantarPatient SatisfactionFemaleUltrasonographymedicine.symptombusiness
researchProduct

Blood-brain barrier disruption by low-frequency ultrasound.

2006

Background and Purpose— A recent study showed a dramatic increase in cerebral hemorrhage comprising atypical locations with low-frequency ultrasound–mediated recombinant tissue plasminogen activator–thrombolysis in humans. Here, we provide a possible explanation for this phenomenon by a side effect observed in a study using the similar ultrasound device. Methods— The study was originally undertaken to investigate by transcranial Doppler sonography, positron emission tomography and perfusion MRI whether transcranial application of wide-field low-frequency ultrasound (300 kHz) improves cerebral hemodynamics in patients with cerebral small vessel disease. Results— Showing no clear positive ef…

Malemedicine.medical_specialtyUltrasonography Doppler TranscranialUltrasonic TherapyPerfusion scanningBrain IschemiaBrain ischemiaParietal LobemedicineHumansCerebral perfusion pressureStrokeAgedAdvanced and Specialized Nursingmedicine.diagnostic_testbusiness.industryUltrasoundHemodynamicsMagnetic resonance imagingMiddle Agedmedicine.diseaseMagnetic Resonance ImagingFrontal LobePositron emission tomographyBlood-Brain BarrierCerebrovascular CirculationPositron-Emission TomographyNeurology (clinical)RadiologyCardiology and Cardiovascular MedicinebusinessPerfusionExtravasation of Diagnostic and Therapeutic MaterialsStroke
researchProduct

Effects of various hygiene procedures on the surface characteristics of titanium abutments.

1996

The use of cleaning instruments on titanium implants may cause undesired surface alterations. In a qualitative and quantitative assessment of these alterations, 5 titanium implant abutments were treated with a steel curet, a prototype pure titanium curet, an air abrasive polishing system, and an ultrasonic system. Custom-made polymer templates, used to secure the curet to a vertical guide bar and a spring scale to maintain a constant instrument pressure, guaranteed a standardized procedure and reproducible results. The ultrasonic and the air abrasive polishing method were also standardized. Evaluation by scanning electron microscopy (SEM) revealed surface alterations for all instruments and…

MicroscopeTitanium implantMaterials scienceScanning electron microscopeSurface PropertiesUltrasonic TherapyDentistrychemistry.chemical_elementPolishingDental Abutmentslaw.inventionCurettagelawQuantitative assessmentPressureDental ImplantsTitaniumMicroscopy Confocalbusiness.industryAbrasiveDental ProphylaxisReproducibility of ResultsDental PolishingchemistrySteelMicroscopy Electron ScanningPeriodonticsUltrasonic sensorbusinessPlasticsBiomedical engineeringTitaniumJournal of periodontology
researchProduct

Histologic Evaluation of Human Intrabony Defects Following Non-Surgical Periodontal Therapy With and Without Application of an Enamel Matrix Protein …

2003

Background: Surgical periodontal treatment with enamel matrix protein derivative (EMD) has been shown to promote periodontal regeneration. However, it is not known whether nonsurgical periodontal therapy with additional subgingival application of EMD may also enhance periodontal regeneration. The purpose of this study was to clinically and histologically evaluate healing of human intrabony defects following non-surgical periodontal treatment with and without application of EMD. Methods: Sixteen patients, each of whom displayed one advanced intrabony defect around teeth or roots scheduled for extraction, were included in the study. The defects were treated as follows: 1) scaling and root pla…

Periodontal treatmentBone RegenerationRoot surfaceUltrasonic Therapymedicine.medical_treatmentAlveolar Bone LossEpithelial AttachmentJunctional epitheliumDentistryScaling and root planingDental Enamel ProteinsPeriodontal Attachment LossEnamel matrix derivativemedicineHumansTreatment FailureReduction (orthopedic surgery)Enamel paintbusiness.industryRegeneration (biology)visual_artvisual_art.visual_art_mediumDental ScalingPeriodonticsPeriodontal IndexbusinessJournal of Periodontology
researchProduct

Evaluation of apical preparations performed with ultrasonic diamond and stainless steel tips at different intensities using a scanning electron micro…

2011

Objective: The objective of our study is to analyse (with the help of scanning electron microscopes) the quality of the dental root surface and the appearance of dental cracks after performing apical preparations using two diffe-rent types of ultrasonic tips. Study design: We used 32 single-rooted teeth that underwent a root canal and apical resection. Afterwards, the teeth were divided into 4 groups of 8 teeth each, with preparations of the apical cavities in the following manner: Group 1: stainless steel ultrasonic tip at 33KHz. Group 2: stainless steel ultrasonic tip at 30KHz. Group 3: diamond ultrasonic tip at 30KHz. Group 4: diamond ultrasonic tip at 33 KHz. The quality of the root sur…

Root surfaceMaterials scienceScanning electron microscopeUltrasonic TherapyRoot canalmedicine.medical_treatmentOdontologíaengineering.materialTherapeutic ultrasoundmental disordersMicroscopymedicineHumansComposite materialGeneral DentistryApicoectomyDiamondScanning electron microscope:CIENCIAS MÉDICAS [UNESCO]Stainless SteelCiencias de la saludRoot Canal TherapyEndodontic surgerymedicine.anatomical_structureOtorhinolaryngologyApicoectomyUNESCO::CIENCIAS MÉDICASMicroscopy Electron ScanningengineeringResearch-ArticleSurgeryUltrasonic sensorDentinal crackDiamondOral Surgery
researchProduct