Effect of Thermomechanical and Static Loading on the Load to Fracture of Metal‐Ceramic, Monolithic and Veneered Zirconia Posterior Fixed Partial Dent…

2018

PURPOSE To evaluate the influence of static (not preloaded) and thermomechanical loading on the load to fracture of metal-ceramic, monolithic and veneered zirconia computer-aided design/computer-aided manufacturing (CAD/CAM) posterior fixed partial dentures (FPDs). MATERIALS AND METHODS One hundred standardized specimens with 2 abutments screwed onto a platform were prepared from stainless steel to receive a posterior 3-unit FPD with an intermediate pontic. Specimens were randomly divided into 5 groups (n = 20): Metal-ceramic (control group), Lava Zirconia system, Vita In-Ceram YZ, IPS e.max ZirCAD, and Lava Plus. Half of the specimens of each group (n = 10) underwent no preloading, and the…

Dental Stress AnalysisMaterials scienceMetal Ceramic AlloysDental Abutments02 engineering and technologyCrossheadDental MaterialsRandom Allocation03 medical and health sciences0302 clinical medicineMaterials TestingFixed partial denturesCubic zirconiaDental Restoration FailureComposite materialGeneral DentistryUniversal testing machineFracture loadMonolithic zirconia030206 dentistryStainless Steel021001 nanoscience & nanotechnologyMetal ceramicDental VeneersFracture (geology)Computer-Aided DesignDenture Partial FixedStress MechanicalZirconium0210 nano-technologyJournal of Prosthodontics
researchProduct

Disinclusion of unerupted teeth by mean of self-ligating brackets: Effect of blood contamination on shear bond strength

2012

Objectives: The aim of this study was to assess the effect of blood contamination on the shear bond strength and failure site of three different orthodontic self-ligating brackets. Study Design: 240 bovine permanent mandibular incisors were randomly divided into 12 groups of 20 specimens each. Orthodontic self-ligating brackets were tested under four different enamel surface conditions: a) dry, b) blood contamination before priming, c) blood contamination after priming, d) blood contamination before and after priming. Brackets were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statis…

Dental Stress AnalysisMaterials scienceOrthodontic BracketsBlood contaminationDentistryOdontologíaOrthodonticsDental bondingstomatognathic systemShear strengthAnimalsTooth UneruptedGeneral DentistryOrthodonticsUniversal testing machineEnamel paintBond strengthbusiness.industryDental Bonding:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludShear bondstomatognathic diseasesBloodOtorhinolaryngologyvisual_artUNESCO::CIENCIAS MÉDICASvisual_art.visual_art_mediumCattleResearch-ArticleSurgeryAdhesiveShear StrengthbusinessMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

In vitro retentive strength of zirconium oxide ceramic crowns using different luting agents

2005

Statement of problem In contrast to gold crowns, in vitro determination of the retentive strength of all-ceramic crowns is more difficult because components allowing connection to testing apparatus are not as easily integrated into the all-ceramic material. Nevertheless, retentive strength data are crucial for obtaining information about the potential clinical performance of luting cements for all-ceramic restorations. Therefore, a new in vitro model was necessary to evaluate the retentive strength of all-ceramic crowns. Purpose The purpose of this in vitro study was to determine the retentive strength of 4 resin-cement systems, a compomer, a glass-ionomer cement, a resin-modified glass-ion…

Dental Stress AnalysisMaterials sciencemedicine.medical_treatmentDental CementsDentistryCrown (dentistry)Dental Prosthesis RetentionDental porcelainstomatognathic systemDental cementMaterials TestingmedicineHumansCeramicComposite materialCementationCementUniversal testing machineCrownsCompomersbusiness.industryLuting agentEpoxyDental PorcelainResin CementsGlass Ionomer Cementsvisual_artvisual_art.visual_art_mediumZirconiumOral SurgerybusinessThe Journal of Prosthetic Dentistry
researchProduct

Comparison of the effect of different surface treatments on the bond strength of different cements with nickel chromium metal alloy: An in vitro study

2017

Background For success of any indirect metal restoration, a strong bond between cement and the intaglio surface of metal is imperative. The aim of this study is to evaluate and compare the effect of different surface treatment on the tensile and shear bond strength of different cements with nickel–chromium alloy. Material and Methods 120 premolars were sectioned horizontally parallel to the occlusal surface to expose the dentin. Wax patterns were fabricated for individual tooth followed by casting them in nickel chromium alloy. 60 samples were tested for tensile bond strength, and the remaining 60 for shear bond strength. The samples were divided into three groups (of 20 samples each) as pe…

Materials science0206 medical engineeringAlloyGlass ionomer cement02 engineering and technologyengineering.material03 medical and health sciences0302 clinical medicineUltimate tensile strengthDentinmedicineComposite materialGeneral DentistryCementProsthetic DentistryUniversal testing machineBond strengthResearchtechnology industry and agriculture030206 dentistry:CIENCIAS MÉDICAS [UNESCO]equipment and supplies020601 biomedical engineeringmedicine.anatomical_structureCasting (metalworking)UNESCO::CIENCIAS MÉDICASengineeringJournal of Clinical and Experimental Dentistry
researchProduct

Comparison of spring characteristics of titanium-molybdenum alloy and stainless steel

2017

Background Titanium-molybdenum alloy (TMA) and stainless steel (SS) wires are commonly used in orthodontics as arch-wires for tooth movement. However, plastic deformation phenomenon in these arch-wires seems to be a major concern among orthodontists. This study aimed to compare the mechanical properties of TMA and SS wires with different dimensions. Material and Methods Seventy-two wire samples (36 TMA and 36 SS) of three different sizes (19×25, 17×25 and 16×22) were analyzed in vitro, with 12 samples in each group. Various mechanical properties of the wires, including spring-back, bending moment and stiffness were determined using a universal testing machine. Student’s t-test showed statis…

Materials scienceAlloyOrthodonticsOdontología02 engineering and technologyengineering.materiallaw.inventionTitanium molybdenum alloy03 medical and health sciences0302 clinical medicineOptical microscopelawmedicineComposite materialGeneral DentistryUniversal testing machineResearch020502 materialsStiffness030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Ciencias de la salud0205 materials engineeringSpring (device)Tooth movementUNESCO::CIENCIAS MÉDICASengineeringBending momentmedicine.symptom:CIENCIAS MÃ DICAS [UNESCO]
researchProduct

Effect of alloy type and casting technique on the fracture strength of implant-cemented structures.

2010

Objectives: To evaluate the influence of alloy type and casting procedure on the fracture strength (FS) of metallic frameworks for implant-supported fixed prostheses. Study design: Thirty three-unit structures for lower posterior bridges were waxed-up and randomly assigned to two groups (n=15) according to alloy type and casting technique: Group 1 (C): cobalt-chromium cast in a centrifugal machine (TS1, Degussa-Hüls); Group 2 (T): titanium cast in a pressure-differential device (Cyclarc II, Morita). Each structure was cemented onto two prefabricated abutments under a constant seating pressure. After 6 months of water aging, samples were loaded in a static universal testing machine (EFH/5/FR…

Materials scienceAlloychemistry.chemical_elementDental Cementsengineering.materialWater agingFlexural strengthMaterials TestingAlloysHardness TestsComposite materialGeneral DentistryUniversal testing machineDental Casting Technique:CIENCIAS MÉDICAS [UNESCO]OtorhinolaryngologychemistryCasting (metalworking)UNESCO::CIENCIAS MÉDICASengineeringFracture (geology)Microscopy Electron ScanningSurgeryImplantDental Prosthesis Implant-SupportedTitaniumMedicina oral, patologia oral y cirugia bucal
researchProduct

Effect of water contamination on the shear bond strength of five orthodontic adhesives

2010

Objectives: To evaluate the shear bond strength and site of failure of brackets bonded to dry and wet enamel. Study design: 50 teeth were divided into ten groups of 5 teeth each (10 surfaces). In half the groups enamel was kept dry before bonding, and in the other half distilled water was applied to wet the surface after etching. The following groups were established: 1)Acid/Transbond-XT (dry/wet) XT; 2) Transbond Plus Self Etching Primer (TSEP)/Transbond-XT paste (dry/wet); 3) Concise (dry), Transbond MIP/Concise (wet), 4) FujiOrtho-LC (dry/ wet); 5) SmartBond (dry/wet). Brackets were bonded to both buccal and lingual surfaces. Specimens were stored in distilled water (24 hours at 37ºC) an…

Materials scienceDental materialsWater contaminationMaterials dentalsCementDental CementsIn Vitro TechniquesCimentOrthodontic Adhesivesstomatognathic systemHumansComposite materialGeneral DentistryUniversal testing machineContaminació de l'aiguaAdhesius dentalsEnamel paintBond strengthDental BondingWaterHumidity:CIENCIAS MÉDICAS [UNESCO]Shear bondOtorhinolaryngologyDistilled waterWater pollutionvisual_artUNESCO::CIENCIAS MÉDICASvisual_art.visual_art_mediumSurgeryAdhesiveDental adhesives
researchProduct

Casein phosphopeptide-amorphous calcium phosphate effects on brackets shear bond strength and enamel damage

2017

Background The aim of study was to evaluate the application of casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) and fluoride regarding their effect on the shear bond strength (SBS), bond failure pattern of brackets using the adhesive remnant index (ARI) and assessing the quality of enamel surface using the enamel damage index (EDI). Material and methods Sixty extracted premolar teeth were randomly divided into four groups regarding pretreatment application of CPP-ACP and fluoride. Brackets were bonded using the conventional method. Specimens were thermocycled for 1000 cycles and were subsequently tested for the SBS in a universal testing machine. After debonding, the teeth were e…

Materials scienceDentistryOrthodontics030207 dermatology & venereal diseases03 medical and health scienceschemistry.chemical_compound0302 clinical medicinestomatognathic systemPremolarmedicineAmorphous calcium phosphateGeneral DentistryUniversal testing machineEnamel paintBond strengthbusiness.industryResearchBracket030206 dentistry:CIENCIAS MÉDICAS [UNESCO]stomatognathic diseasesmedicine.anatomical_structurechemistryvisual_artUNESCO::CIENCIAS MÉDICASvisual_art.visual_art_mediumAdhesivebusinessFluoride
researchProduct

Effect of temperature on the orthodontic clinical applications of NiTi closed-coil springs

2013

NiTi spring coils were used to obtain large deformation under a constant force. The device consists on a NiTi coil spring, superelastic at body temperature, in order to have a stress plateau during the austenitic retransformation during the unloading. The temperature variations induced changes in the spring force. Objectives: The aim of this study is to investigate the effect of the temperature variations in the spring forces and corrosion behaviour simulating the ingestion hot/cold drinks and food. Study D esign: The springs were subjected to a tensile force using universal testing machine MTS-Adamel (100 N load cell). All tests were performed in artificial saliva maintained at different t…

Materials scienceElasticidadOrtodòncia616.3OdontologíaOrthodontics:Enginyeria dels materials [Àrees temàtiques de la UPC]Load cellNiTiCorrosionPhysical PhenomenaStress (mechanics)RecoveryMaterials TestingBiomaterials and Bioengineering in DentistryOrthodontic WiresOrthodonticComposite materialSuperelasticitySalivaGeneral DentistryUniversal testing machineElasticitatTemperatureNíquel-titani -- AliatgesCoilsTemperatura:CIENCIAS MÉDICAS [UNESCO]Coil springCiencias de la saludElasticityOrtodonciaNickel-titanium alloysSpringsOtorhinolaryngologySpring (device)Nickel titaniumPseudoelasticityUNESCO::CIENCIAS MÉDICASResearch-ArticleSurgery
researchProduct

Comparative In Vitro Study of the Bond Strength of Composite to Carbon Fiber Versus Ceramic to Cobalt–Chromium Alloys Frameworks for Fixed Dental Pro…

2020

Purpose: The aim of this comparative in vitro study was to assess the bond strength and mechanical failure of carbon-fiber-reinforced composites against cobalt&ndash

Materials scienceMaterial sanitarioComposite numberMateriales dentaleschemistry.chemical_elementOdontología02 engineering and technologyBendingFiber-reinforced compositelcsh:TechnologyArticlecarbon fiber03 medical and health sciences0302 clinical medicinethree-point bend testGeneral Materials ScienceCeramicComposite materiallcsh:MicroscopyFailure assessmentlcsh:QC120-168.85fiber-reinforced compositebond strengthUniversal testing machinelcsh:QH201-278.5Bond strengthlcsh:T030206 dentistry021001 nanoscience & nanotechnologyPrótesis dentalCo–Cr alloyflexural propertiesadhesionchemistrylcsh:TA1-2040visual_artvisual_art.visual_art_mediumlcsh:Descriptive and experimental mechanicslcsh:Electrical engineering. Electronics. Nuclear engineeringmetal ceramic0210 nano-technologylcsh:Engineering (General). Civil engineering (General)Cobaltlcsh:TK1-9971Materials