Search results for "Urban waste"
showing 10 items of 23 documents
Anaerobic membrane bioreactors (AnMBR) treating urban wastewater in mild climates
2020
[EN] Feasibility of an AnMBR demonstration plant treating urban wastewater (UWW) at temperatures around 25-30 degrees C was assessed during a 350-day experimental period. The plant was fed with the effluent from the pretreatment of a full-scale municipal WWTP, characterized by high COD and sulfate concentrations. Biodegradability of the UWW reached values up to 87%, although a portion of the biodegradable COD was consumed by sulfate reducing organisms. Effluent COD remained below effluent discharge limits, achieving COD removals above 90%. System operation resulted in a reduction of sludge production of 36-58% compared to theoretical aerobic sludge productions. The membranes were operated a…
Modeling the anaerobic treatment of sulfate rich urban wastewater. Application to AnMBR technology
2020
[EN] Although anaerobic membrane bioreactors (AnMBR) are a core technology in the transition of urban wastewater (UWW) treatment towards a circular economy, the transition is being held back by a number of bottlenecks. The dissolved methane released from the effluent, the need to remove nutrients (ideally by recovery), or the energy lost by the competition between methanogenic and sulfate-reducing bacteria (SRB) for the biodegradable COD have been identified as the main issues to be addressed before AnMBR becomes widespread. Mathematical modeling of this technology can be used to obtain further insights into these bottlenecks plus other valuable information for design, simulation and contro…
Widening the applicability of AnMBR for urban wastewater treatment through PDMS membranes for dissolved methane capture: Effect of temperature and hy…
2021
[EN] AnMBR technology is a promising alternative to achieve future energy-efficiency and environmental-friendly urban wastewater (UWW) treatment. However, the large amount of dissolved methane lost in the effluent represents a potential high environmental impact that hinder the feasibility of this technology for full-scale applications. The use of degassing membranes (DM) to capture the dissolved methane from AnMBR effluents can be considered as an interesting alternative to solve this problem although further research is required to assess the suitability of this emerging technology. The aim of this study was to assess the effect of operating temperature and hydrodynamics on the capture of…
Use of physicochemical processing in treating urban waste waters
1994
The principal objective of the present study was to compare two clearly defined purification processes in two stages: the periods 1985–1987 (conventional) and 1988–1990 (physico‐chemical). In general, the mean concentrations obtained were lower in the second period. A z‐test for comparing means was applied, but no significant correlation was observed (p ≤ 0.05). The mean concentrations obtained (with some exceptions) are lower in the second period. With the passing of time, the total volume of sewage flow has increased, and hence the load of contaminants has become diluted. The use of physico‐chemical treatment prior to biological processing may be the cause of the increase in cost.
Designing an AnMBR-based WWTP for energy recovery from urban wastewater: The role of primary settling and anaerobic digestion
2015
The main objective of this paper is to assess different treatment schemes for designing a submerged anaerobic membrane bioreactor (AnMBR) based WWTP. The economic impact of including a primary settling (PS) stage and further anaerobic digestion (AD) of the wasted sludge has been evaluated. The following operating scenarios were considered: sulphate-rich and low-sulphate urban wastewater (UWW) treatment at 15 and 30 ºC. To this aim, the optimum combination of design/operating parameters that resulted in minimum total cost (CAPEX plus OPEX) for the different schemes and scenarios was determined. The AnMBR design was based on both simulation and experimental results from an AnMBR plant featuri…
Multicriteria performance analysis of an integrated urban wastewater system for energy management
2017
AbstractThe optimization and management of an integrated urban wastewater system is a complex problem involving many processes and variables. The possible control options are defined by several management strategies that may differently impact the economic, operational or environmental performance of the system. The present paper aims to contribute to the environmental and energy sustainability of urban wastewater systems by means of a multicriteria performance analysis. The paper begins with a complete analysis of the system performance in several fields of interest (energy, environment, quality of service, operation, economy and financial resources), and it highlights the management stren…
A Graphical User Interface as a DSS Tool for GHG Emission Estimation from Water Resource Recovery Facilities
2017
A Grafical User Interface (GUI) for the greenhouse gas (GHG) emissions from WWTPs based on four models aimed at quantifying the gas emissions from the aerated tanks (i.e. CAS and MBR reactor), aerobic digesters, secondary clarifiers and anaerobic digesters have been englobed in a GUI in order to provide a valid decision support system (DSS) to the practitioners. The GUI allows to estimate such emissions for the different WWTP phases considered. The GUI has been developed on MATLAB platform and provides as output the GHG emissions in terms of CO2 and N2O fluxes.
Instrumentation, control, and automation for submerged anaerobic membrane bioreactors
2015
A submerged anaerobic membrane bioreactor (AnMBR) demonstration plant with two commercial hollow-fibre ultrafiltration systems (PURON® , Koch Membrane Systems, PUR-PSH31) was designed and operated for urban wastewater treatment. An instrumentation, control, and automation (ICA) system was designed and implemented for proper process performance. Several single-input-single-output (SISO) feedback control loops based on conventional on off and PID algorithms were implemented to control the following operating variables: flow-rates (influent, permeate, sludge recycling and wasting, and recycled biogas through both reactor and membrane tanks), sludge wasting volume, temperature, transmembrane pr…
Thermoeconomic analysis of a coupled municipal solid waste thermovalorization–MSF desalination plant: an Italian case study
2006
Abstract A thermoeconomic analysis of a cogenerative system with steam bleedings produced starting from the thermal energy recovered in a municipal solid waste thermovalorization plant is presented. The authors assume that the bled steam is used to feed a seawater multi-stage flash (MSF) desalination plant. A case study was carried out for the desalination plant, which operates in Raffineria di Gela (Sicily). In particular, the MSF process is described and the most significant features of the plant are presented. Besides, an economic analysis of a hypothetically coupled MSW thermovalorization–MSF plant was carried out to estimate the capital and operating costs and the gain derived from the…
Towards more equity concerning quality of Urban Waste Management services in the context of cities
2018
Abstract An innovative combined evaluation approach is proposed in the present paper to deal with the issue of the performance measurement and comparison of Urban Waste Management (UWM) services in the context of cities. The ELECTRE III method is initially considered as tool able to execute a multi-criteria analysis aimed at ranking UWM systems based on their integration and sustainability levels. The latter are comprehensively evaluated via the recently developed “Wasteaware” Integrated and Sustainability Waste Management indicators framework, which takes into account physical components and governance aspects of UWM systems. Then, on the basis on ELECTRE III results, a practical gaps inve…