Search results for "VISION"

showing 10 items of 5066 documents

Seeing odors in color: Cross-modal associations in children and adults from two cultural environments

2018

International audience; We investigated the occurrence and underlying processes of odor–color associations in French and American 6- to 10-year-old children (n = 386) and adults (n = 137). Nine odorants were chosen according to their familiarity to either cultural group. Participants matched each odor with a color, gave hedonic and familiarity judgments, and identified each odor. By 6 years of age, children displayed culture-specific odor–color associations, but age differences were noted in the type of associations. Children and adults in both cultural groups shared common associations and formed associations that were unique to their environment, underscoring the importance of exposure le…

AdultCross-Cultural ComparisonMalevision[SDV]Life Sciences [q-bio]Ethnic groupColorExperimental and Cognitive PsychologyOlfaction050105 experimental psychologyDevelopmental psychologyJudgment03 medical and health sciences0302 clinical medicineDevelopmental and Educational PsychologyHumans0501 psychology and cognitive sciencesChildAge differences[SDV.NEU.PC]Life Sciences [q-bio]/Neurons and Cognition [q-bio.NC]/Psychology and behaviormusculoskeletal neural and ocular physiology05 social sciencesCultural group selectionRecognition Psychologychild (6–10 years)intercultural differencesSmellOdorOdorantsFemalemultisensory developmentodor–color associationsPsychology030217 neurology & neurosurgerypsychological phenomena and processesolfaction
researchProduct

Visual simulation through different intraocular lenses using adaptive optics: Effect of tilt and decentration

2011

Purpose To analyze visual quality differences between intraocular lenses (IOLs) and assess the impact of IOL decentration and tilt on visual quality. Setting University of Valencia, Valencia, Spain. Design Cohort study. Methods The crx1 adaptive optics visual simulator was used to simulate the wavefront aberration pattern of 2 commercially available aspheric aberration-correcting IOLs (Acrysof IQ SN60WF and Tecnis ZA9003) and 2 spherical IOLs (Akreos Adapt and Triplato) in 5 situations: centered, decentered 0.2 mm and 0.4 mm, and tilted 2 degrees and 4 degrees. Monocular distance visual acuity at 100%, 50%, and 10% contrast and the depth of focus were measured. Results Ten eyes of 10 patien…

AdultDepth of focusCorneal Wavefront AberrationVisual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectVisual AcuityArtificial Lens Implant MigrationCohort StudiesYoung AdultAberrometryPsychophysicsmedicineHumansContrast (vision)Adaptive opticsmedia_commonMathematicsLenses IntraocularDepth PerceptionMonocularAberrometryModels Theoreticalequipment and supplieseye diseasesSensory SystemsOphthalmologySpherical aberrationTilt (optics)OptometrySurgerysense organsmedicine.symptomJournal of Cataract and Refractive Surgery
researchProduct

Can colours be used to segment words when reading?

2015

Rayner, Fischer, and Pollatsek (1998, Vision Research) demonstrated that reading unspaced text in Indo-European languages produces a substantial reading cost in word identification (as deduced from an increased word-frequency effect on target words embedded in the unspaced vs. spaced sentences) and in eye movement guidance (as deduced from landing sites closer to the beginning of the words in unspaced sentences). However, the addition of spaces between words comes with a cost: nearby words may fall outside high-acuity central vision, thus reducing the potential benefits of parafoveal processing. In the present experiment, we introduced a salient visual cue intended to facilitate the process…

AdultEye MovementsComputer sciencemedia_common.quotation_subjectSpeech recognitionExperimental and Cognitive PsychologyYoung AdultArts and Humanities (miscellaneous)Reading (process)Developmental and Educational PsychologyHumansmedia_commonCommunicationbusiness.industryText segmentationEye movementGeneral MedicineWord lists by frequencyPattern Recognition VisualReadingSalientWord recognitionCentral visionbusinessColor PerceptionWord (group theory)Acta Psychologica
researchProduct

Realignment of myocardial first-pass MR perfusion images using an automatic detection of the heart-lung interface

2004

International audience; Abstract: Magnetic resonance first-pass imaging of a bolus of contrast agent is well adapted to distinguish normal and hypoperfused areas of the myocardium. In most cases, the signal intensity-time curves in user defined regions of interest (ROI) are studied. As image acquisition is ECG-gated, the images are acquired at the same moment in the cardiac cycle, and the basic shape of the heart is similar from one view to the next. However, superficial respiratory motion can displace the heart in the short-axis plane. The aim of this study is to correct for the respiratory motion of the heart by performing an automatic realignment of the myocardial ROI based on a method t…

AdultGadolinium DTPAMaleComputer scienceInterface (computing)media_common.quotation_subjectMyocardial InfarctionBiomedical EngineeringBiophysicsContrast MediaImage registration030204 cardiovascular system & hematologySignal030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineCoronary CirculationImage Processing Computer-Assisted[INFO.INFO-IM]Computer Science [cs]/Medical ImagingmedicineHumansmagnetic resonance imagingContrast (vision)Radiology Nuclear Medicine and imagingComputer visionLeast-Squares AnalysisLungAgedmedia_commonLung[ INFO.INFO-IM ] Computer Science [cs]/Medical ImagingCardiac cyclemedicine.diagnostic_testMr perfusionbusiness.industrycontrast-enhanced first-passHeartMagnetic resonance imagingMiddle Agedimage registrationmedicine.anatomical_structureFemaleArtificial intelligencebusinessmyocardial perfusionMagnetic Resonance Imaging
researchProduct

Comparison of contrast-enhanced MR angiography to intraarterial digital subtraction angiography for evaluation of peripheral arterial occlusive disea…

2010

Purpose To evaluate the efficacy and safety of 0.1 mmol/kg gadodiamide administration for contrast-enhanced magnetic resonance angiography (CE-MRA) in detecting hemodynamically relevant main stenosis (ie, ≥50% or occlusion) of aortoiliac arteries. Materials and Methods In a multicenter, phase 3, controlled study, patients with suspected or proven peripheral arterial occlusive disease (PAOD) underwent CE-MRA with administration of gadodiamide. Intraarterial digital subtraction angiography (IA-DSA) was used as the reference. The study was approved by all Institutional Review Boards or Institutional Ethic Committees prior to commencement of patient recruitment and written informed consent was …

AdultGadolinium DTPAMalemedicine.medical_specialtymedia_common.quotation_subjectContrast MediaArterial Occlusive DiseasesSensitivity and SpecificityMagnetic resonance angiographyElectrocardiographyPeripheral arterial occlusive diseaseMulticenter trialOcclusionmedicineHumansContrast (vision)Radiology Nuclear Medicine and imagingcardiovascular diseasesAgedmedia_commonAged 80 and overPeripheral Vascular Diseasesmedicine.diagnostic_testbusiness.industryGadodiamideAngiography Digital SubtractionReproducibility of ResultsDigital subtraction angiographyMiddle Agedmedicine.diseaseeye diseasesStenosiscardiovascular systemFemaleRadiologybusinessMagnetic Resonance Angiographycirculatory and respiratory physiologymedicine.drugJournal of Magnetic Resonance Imaging
researchProduct

Kardiale MRT : Änderungen der normalisierten myokardialen Gadolinium-Anreicherung über die Zeit nach Kontrastmittelinjektion in Patienten mit akuter …

2011

PURPOSE An increased normalized gadolinium accumulation (NGA) in the myocardium during early washout has been used for the diagnosis of acute myocarditis (AM). Due to the fact that the pharmacokinetics of contrast agents are complex, time-related changes in NGA after contrast injection are likely. Because knowledge about time-related changes of NGA may improve the diagnostic accuracy of MR, our study aimed to estimate the time course of NGA after contrast injection in patients as well as in healthy volunteers. MATERIALS AND METHODS An ECG-triggered inversion recovery SSFP sequence with incrementally increasing inversion times was repetitively acquired over the 15 minutes after injection of …

AdultGadolinium DTPAMalemedicine.medical_specialtymedia_common.quotation_subjectGadoliniumCardiac-Gated Imaging TechniquesMedizinchemistry.chemical_elementContrast MediaSensitivity and SpecificityPharmacokineticsReference ValuesInternal medicineHealthy volunteersmedicineImage Processing Computer-AssistedContrast (vision)HumansRadiology Nuclear Medicine and imagingIn patientMuscle Skeletalmedia_commonbusiness.industryMyocardiumWashoutSteady-state free precession imagingMiddle AgedImage EnhancementMagnetic Resonance ImagingMyocardial ContractionMyocarditischemistryContrast injectionAcute DiseaseInjections IntravenousCardiologyFemalebusiness
researchProduct

Focal nodular hyperplasia: typical and atypical MRI findings with emphasis on the use of contrast media

2007

Focal nodular hyperplasia is a benign hypervascular hepatic tumour, frequently detected in asymptomatic patients undergoing imaging studies for unrelated reasons. Magnetic resonance imaging (MRI) generally allows a confident differential diagnosis with other hypervascular liver lesions, either benign or malignant. In addition, due to the recent development of hepatospecific MRI contrast agents, MRI concomitantly enables functional and morphological information to be obtained, thus providing important clues for the detection and characterization of focal nodular hyperplasia lesions.

AdultGadolinium DTPAPathologymedicine.medical_specialtymedia_common.quotation_subjectContrast MediaAsymptomaticDiagnosis DifferentialMeglumineGadolinium DTPAOrganometallic CompoundsmedicineHumansContrast (vision)Radiology Nuclear Medicine and imagingmedia_commonmedicine.diagnostic_testbusiness.industryLiver NeoplasmsFocal nodular hyperplasiaMagnetic resonance imagingGeneral MedicineHepatic tumourmedicine.diseaseMagnetic Resonance ImagingFocal Nodular HyperplasiaFemaleRadiologyDifferential diagnosismedicine.symptombusinessIron CompoundsMri findingsClinical Radiology
researchProduct

Influence of the luminance level on visual performance with a disposable soft cosmetic tinted contact lens.

2001

The purpose of the present work was to study the effect on visual performance of wearing disposable soft tinted contact lenses for cosmetic purposes. Parameters such as contrast sensitivity (Vistech 6000), colour vision (Farnsworth-Munsell 100-Hue colour test), visual fields (static Goldmann perimetry) and subjective vision (what the wearer feels while wearing the lenses) were studied under different illumination levels in order to check for possible vision losses while wearing these contact lenses at low illumination levels. Sixteen emmetropic subjects were fitted consecutively with seven pairs of different colour lenses (Optima Colors lenses by BauschLomb), and the experimental parameters…

AdultGoldmann perimetryAdolescentmedia_common.quotation_subjectColour VisionEmmetropiaColorContact Lenses HydrophilicLuminanceSensory SystemsContact lensContrast SensitivityOphthalmologyContrast (vision)OptometryHumansVisual Field TestsVisual FieldsColor PerceptionLightingVision OcularOptometryMathematicsmedia_commonOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct

Effect of cordycepin on interleukin-10 production of human peripheral blood mononuclear cells

2002

Therapeutic options for controlling autoimmune diseases are still very limited. Interleukin-10 has been reported to be a promising approach to therapeutic intervention. In the search for a drug which results in the selective upregulation of interleukin-10, we investigated the immunoregulative effects of cordycepin. We have measured interleukin-10 and interleukin-2 secretion of human peripheral blood mononuclear cells that were incubated with cordycepin and assessed the influence of cordycepin on the expression of interleukin-10 mRNA, the proliferative response and the expression of surface markers on T lymphocytes. In addition, the subsets of interleukin-10-secreting cells, the influence of…

AdultInterleukin 2T-Lymphocytesmedicine.medical_treatmentPharmacologyBiologyLymphocyte ActivationPeripheral blood mononuclear cellchemistry.chemical_compoundAdjuvants ImmunologicAntigens CDmedicineHumansRNA MessengerIL-2 receptorCells CulturedPharmacologyDeoxyadenosinesDose-Response Relationship DrugCordycepinMonocyteInterleukinFlow CytometryInterleukin-10Up-RegulationInterleukin 10medicine.anatomical_structureCytokinechemistryImmunologyLeukocytes MononuclearInterleukin-2Cell Divisionmedicine.drugEuropean Journal of Pharmacology
researchProduct

The influence of scene and object orientation on the scene consistency effect

2019

Abstract Contextual regularities help us make sense of our visual environment. In scenes, semantically consistent objects are typically better recognized than inconsistent ones (e.g., a toaster vs. printer in a kitchen). What is the role of object and scene orientation in this so-called scene consistency effect? We presented consistent and inconsistent objects either upright (Experiment 1) or inverted (rotated 180°; Experiment 2) on upright, inverted, and scrambled background scenes. In Experiment 1, on upright scenes, consistent objects were recognized with higher accuracy than inconsistent ones, and we observed N300/N400 event-related potentials (ERPs) reflecting object-scene semantic pro…

AdultMale0303 health sciencesbusiness.industryComputer scienceCognitive neuroscience of visual object recognitionBrainObject processingN400SemanticsYoung Adult03 medical and health sciencesBehavioral Neuroscience0302 clinical medicinePattern Recognition VisualHumansSemantic memoryObject-orientationFemaleComputer visionArtificial intelligencebusinessEvoked Potentials030217 neurology & neurosurgery030304 developmental biologyBehavioural Brain Research
researchProduct