Complications following the use of alloplastic materials in urogynecological surgery
2011
Abstract Study design 118 patients, who were admitted from 2005 to 2008 to our department due to complications following mesh implantation, were included in a retrospective survey. We investigated patient symptoms, findings and subsequent patient management. There was a re-evaluation of symptoms in a follow-up eight weeks after the revision procedure. Data from our urogynecological file archive were used. Results The main complaints were de novo urgency, pain and recurrent urinary tract infections. The main findings were mesh erosion and infections including abscess formations and osteomyelitis. Before being admitted to our department, 42 patients (35.6%) had already undergone at least one …
Prevalence of general binocular dysfunctions in a population of university students.
1997
Although some authors report that the prevalence of general binocular dysfunctions (nonstrabismic) for nonpresbyopes in the clinical population is greater than any condition except refractive error, limited research is available to support this statement. This clinical study determined the presence and clinical implications of these conditions in a population of university students with heavy near visual demands.From a group of second year students who were given a thorough eye examination, 65 students were selected. The criteria for selection were the absence of significant uncorrected refractive error, healthy eyes, and no strabismus or amblyopia.32.3% of the subjects showed general binoc…
The effect of simulated normal and amblyopic higher-order aberrations on visual performance.
2012
Purpose To study the effect of simulated amblyopic and normal higher-order aberrations on visual performance of normal eyes. Methods To assess visual function, an adaptive optics visual simulator was used to compensate volunteers' ocular aberrations and simulate the wavefront aberration patterns found in healthy and amblyopic eyes in 7 healthy individuals. Visual acuity for high (100%), medium (50%), and low (10%) contrast and contrast sensitivity at 10, 20, and 25 cycles per degree (cpd) were measured after simulation of both pattern aberrations. The modulation transfer function and the point spread function were computed based on the aberration data. All measures were taken for 3 and 5.5 …
Chromatic and achromatic visual fields in relation to choroidal thickness in patients with high myopia: A pilot study
2018
Purpose. - To analyse the relationship between the choroidal thickness and the visual perception of patients with high myopia but without retinal damage. Methods. - All patients underwent ophthalmic evaluation including a slit lamp examination and dilated ophthalmoscopy, subjective refraction, best corrected visual acuity, axial length, optical coherence tomography, contrast sensitivity function and sensitivity of the visual pathways. Results. - We included eleven eyes of subjects with high myopia. There are statistical correlations between choroidal thickness and almost all the contrast sensitivity values. The sensitivity of magnocellular and koniocellular pathways is the most affected, an…
Cizolirtine Citrate, an Effective Treatment for Symptomatic Patients with Urinary Incontinence Secondary to Overactive Bladder: A Pilot Dose-Finding …
2009
Abstract Background A dose-finding study was performed as the first step in the clinical development of the new drug, cizolirtine citrate. Objective To assess the efficacy and safety of cizolirtine citrate in overactive bladder with urinary incontinence. Design, setting, and participants Seventy-nine outpatients with clinical overactive bladder and/or urodynamic diagnosis of detrusor overactivity were randomized in a multicentre, 12-wk, double-blind, pilot trial. Interventions Patients received cizolirtine citrate 400mg bid (C400), cizolirtine citrate 200mg bid (C200), or placebo. Measurements Patients recorded efficacy variables in 7- and 14-d bladder diaries: urinary incontinence episodes…
Contrast sensitivity after LASIK flap creation with a femtosecond laser and a mechanical microkeratome
2007
ABSTRACT PURPOSE: To compare the effects on contrast sensitivity of the IntraLase femtosecond laser for flap creation (IntraLASIK) and standard LASIK for myopia. METHODS: Two hundred eyes of 100 consecutive patients underwent LASIK treatment using the VISX S2 laser system. The femtosecond laser (15 kHz IntraLase) was used for flap creation in 100 eyes (50 patients) and a mechanical microkeratome (Carriazo-Barraquer) was used in 100 eyes (50 patients). Best spectacle-corrected contrast sensitivity was measured before and 6 months postoperatively in the IntraLASIK and mechanical LASIK groups. The IntraLASIK and mechanical LASIKinduced changes in contrast sensitivity were compared under photop…
Contrast sensitivity after implantation of toric iris-claw lenses in phakic eyes.
2004
Abstract Purpose: To evaluate the change in contrast sensitivity after implantation of the Verisyse toric phakic intraocular lens (IOL) (AMO) for the correction of myopia with astigmatism. Setting: Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods: Eighteen eyes had implantation of an iris-supported toric phakic IOL to correct myopia with astigmatism. The mean preoperative spherical equivalent was −12.65 diopters ± 3.6 (SD). The contrast sensitivity with best spectacle correction was determined before surgery and 3 months after surgery using the CSV-1000 HGT instrument (Vector Vision Inc.). Results: Three months after IOL implantation, the mean contrast sen…
Eye position tunes the contribution of allocentric and egocentric information to target localization in human goal-directed arm movements.
1997
Subjects were required to point to the distant vertex of the closed and the open configurations of the Muller-Lyer illusion using either their right hand (experiment 1) or their left hand (experiment 2). In both experiments the Muller-Lyer figures were horizontally presented either in the left or in the right hemispace and movements were executed using either foveal or peripheral vision of the target. According to the illusion effect, subjects undershot and overshot the vertex location of the closed and the open configuration, respectively. The illusion effect decreased when the target was fixated and when the stimulus was positioned in the right hemispace. These results confirm the hypothe…
Advance care planning in participative social work practice
2009
Advanced and anticipatory care planning (acp) are processes for finding out and recording clients’ preferences for care and treatment in the future, and distinct from professional care planning as part of care management in coordinating service delivery. Developing from palliative care practice in recording patients’ decisions to refuse treatment made in advance of possible mental incapacity at end of life, acp processes have recently extended to health and social care provision for long-term conditions. The process aims to engage clients, family members and informal caregivers in thinking ahead about managing difficult care situations. Research indicates that this increases clients’ satisf…
The PolarLITIS Dataset: Road Scenes Under Fog
2022
Road scene analysis is a fundamental task for both autonomous vehicles and ADAS systems. Nowadays, one can find autonomous vehicles that are able to properly detect objects in the scene in good weather conditions; however, some improvements still need to be done when the visibility is altered. People claim that using some non-conventional sensors such as, infra-red or Lidar, combined with classical vision, enhances road scene analysis in optimal weather conditions. In this work, we present the improvements achieved using polarimetric imaging in the complex situation of some adverse weather conditions. This rich modality is known for its ability to describe an object not only by its intensit…