Search results for "VISION"
showing 10 items of 5066 documents
Methods to Evaluate Lighting Quality in Educational Environments
2015
Abstract The current standard for lighting of indoor work places (EN 12464-1) essentially prescribes values of photometric quantities (illuminance, Unified Glare Index, etc.); therefore it does not allow a comprehensive analysis of the luminous environment. In Italy, educational buildings do not always comply with the standard requirements for lighting. Therefore an analysis of their current state is needed and this paper illustrates two methods, developed by the authors, to carry out this investigation: the former is based on the analysis of luminance maps obtained through the HDR imaging technique whereas the latter focuses on the evaluation of non-visual effects of light.
New Objective Refraction Metric Based on Sphere Fitting to the Wavefront
2017
Purpose. To develop an objective refraction formula based on the ocular wavefront error (WFE) expressed in terms of Zernike coefficients and pupil radius, which would be an accurate predictor of subjective spherical equivalent (SE) for different pupil sizes.Methods. A sphere is fitted to the ocular wavefront at the center and at a variable distance,t. The optimal fitting distance,topt, is obtained empirically from a dataset of 308 eyes as a function of objective refraction pupil radius,r0, and used to define the formula of a new wavefront refraction metric (MTR). The metric is tested in another, independent dataset of 200 eyes.Results. For pupil radiir0≤2 mm, the new metric predicts the equ…
Intraocular Telescopic System Design: Optical and Visual Simulation in a Human Eye Model
2016
Purpose. To design an intraocular telescopic system (ITS) for magnifying retinal image and to simulate its optical and visual performance after implantation in a human eye model. Methods. Design and simulation were carried out with a ray-tracing and optical design software. Two different ITS were designed, and their visual performance was simulated using the Liou-Brennan eye model. The difference between the ITS was their lenses’ placement in the eye model and their powers. Ray tracing in both centered and decentered situations was carried out for both ITS while visual Strehl ratio (VSOTF) was computed using custom-made MATLAB code. Results. The results show that between 0.4 and 0.8 mm of d…
Comparison of Micro X-ray Computer Tomography Image Segmentation Methods: Artificial Neural Networks Versus Least Square Support Vector Machine
2013
Micro X-ray computer tomography (XCT) is a powerful non-destructive method for obtaining information about rock structures and mineralogy. A new methodology to obtain porosity from 2D XCT digital images using artificial neural network and least square support vector machine is demonstrated following these steps: the XCT image was first preprocessed, thereafter clustering algorithms such as K-means, Fuzzy c-means and self-organized maps was used for image segmentation. Then artificial neural network was applied for image classification. For comparison, least square support vector machine approach was used for classification labeling of the scan images. The methodology shows how artificial ne…
Fuzzy C-Means Segmentation on Brain MR Slices Corrupted by RF-Inhomogeneity
2007
Brain MR Images corrupted by RF-Inhomogeneity exhibit brightness variations in such a way that a standard Fuzzy C-Means (fcm) segmentation algorithm fails. As a consequence, modified versions of the algorithm can be found in literature, which take into account the artifact. In this work we show that the application of a suitable pre-processing algorithm, already presented by the authors, followed by a standard fcm segmentation achieves good results also. The experimental results ones are compared with those obtained using SPM5, which can be considered the state of the art algorithm oriented to brain segmentation and bias removal.
Illumination Correction on MR Images
2006
Objective. An important artifact corrupting Magnetic Resonance Images is the rf inhomogeneity, also called bias artifact. This anomaly produces an abnormal illumination fluctuation on the image, due to variations of the device magnetic field. This artifact is particularly strong on images acquired with a device specialized on upper and lower limbs due to their coil configuration. A method based on homomorphic filtering aimed to suppress this artifact was proposed by Guillemaud. This filter has two faults: it doesnt provide an indication about the cutoff frequency (cf) and introduces another illumination artifact on the edges of the foreground. This work is an improvement to this method because i…
Bright Retinal Lesions Detection using Color Fundus Images Containing Reflective Features
2009
Recently, the research community has developed many techniques to detect and diagnose diabetic retinopathy with retinal fundus images. This is a necessary step for the implementation of a large scale screening effort in rural areas where ophthalmologists are not available. In the United States of America, the incidence of diabetes is increasing among the young population. Retina fundus images of patients younger than 20 years old present a high amount of reflectance due to the Nerve Fibre Layer (NFL). Generally, the younger the patient the more the reflectance is visible. We are not aware of algorithms able to explicitly deal with this type of artifact.
Volumetric Bias Correction
2007
This paper presents a method to suppress the bias artifact, also known as RF-inhomogeneity, in Magnetic Resonance Imaging (MRI). This artifact produces illumination variations due to magnetic field fluctuations of the device. In the latest years many works have been devoted to face this problem. In this work we present the 3D version of a new approach to bias correction, which is called Exponential Entropy Driven Homomorphic Unsharp Masking (E2D-HUM). This technique has been already presented by some of the authors for the 2D case only. The description of the whole method is detailed, and some experimental results are reported.
An offline/real-time artifact rejection strategy to improve the classification of multi-channel evoked potentials
2008
The primary goal of this paper is to improve the classification of multi-channel evoked potentials (EPs) by introducing a temporal domain artifact detection strategy and using this strategy to (a) evaluate how the performance of classifiers is affected by artifacts and (b) show how the performance can be improved by detecting and rejecting artifacts in offline and real-time classification experiments. Using a pattern recognition approach, an artifact is defined in this study as any signal that may lead to inaccurate classifier parameter estimation and inaccurate testing. The temporal domain artifact detection tests include: a within-channel standard deviation (STD) test that can detect sign…
User grouping and power allocation in NOMA systems: a novel semi-supervised reinforcement learning-based solution
2022
Author's accepted manuscript In this paper, we present a pioneering solution to the problem of user grouping and power allocation in non-orthogonal multiple access (NOMA) systems. The problem is highly pertinent because NOMA is a well-recognized technique for future mobile radio systems. The salient and difcult issues associated with NOMA systems involve the task of grouping users together into the prespecifed time slots, which are augmented with the question of determining how much power should be allocated to the respective users. This problem is, in and of itself, NP-hard. Our solution is the frst reported reinforcement learning (RL)-based solution, which attempts to resolve parts of thi…