Search results for "VISUALIZATION"
showing 10 items of 449 documents
MetNet: A two-level approach to reconstructing and comparing metabolic networks
2021
Metabolic pathway comparison and interaction between different species can detect important information for drug engineering and medical science. In the literature, proposals for reconstructing and comparing metabolic networks present two main problems: network reconstruction requires usually human intervention to integrate information from different sources and, in metabolic comparison, the size of the networks leads to a challenging computational problem. We propose to automatically reconstruct a metabolic network on the basis of KEGG database information. Our proposal relies on a two-level representation of the huge metabolic network: the first level is graph-based and depicts pathways a…
Emphasizing visualization and physical applications in the study of eigenvectors and eigenvalues
2016
The cone of gaze
2011
Gaze direction is an important cue that regulates social interactions. Although humans are very accurate in determining gaze directions in general, they have a surprisingly liberal criterion for the presence of mutual gaze. We first established a psychophysical task to measure the cone of gaze, which required observers to adjust the eyes of a virtual head to the margins of the area of mutual gaze. Then we examined differences between 2D, 3D, and genuine real life gaze. Finally, the tolerance for image distortions when the virtual head is not viewed from the proper vantage point was investigated. Gaze direction was remarkably robust toward loss in detail and distortion. Important lessons for…
A Novel Marking Reader for Progressive Addition Lenses Based on Gabor Holography
2016
PURPOSE Progressive addition lenses (PALs) are marked with permanent engraved marks (PEMs) at standardized locations. Permanent engraved marks are very useful through the manufacturing and mounting processes, act as locator marks to re-ink the removable marks, and contain useful information about the PAL. However, PEMs are often faint and weak, obscured by scratches, partially occluded, and difficult to recognize on tinted lenses or with antireflection or scratch-resistant coatings. The aim of this article is to present a new generation of portable marking reader based on an extremely simplified concept for visualization and identification of PEMs in PALs. METHODS Permanent engraved marks o…
Improving a traffic operator interface using an ontology and intelligent rules
2007
The Transportation and traffic domain is cross-disciplinary; Different areas must be covered to solve complex problems. It also involves the use of different systems for monitoring, visualization, information distribution, control, communication, etc. All of these systems are implemented using different levels of technology. In most cases the control of these systems is handled by [graphic] user interfaces. In the past years the number of systems has grown substantially and because of their "monolytic" design, they have different and in most cases not-compatible user-interfaces. A generic interface would be useful to improve not only the different processes but also the efficiency of the op…
Three-dimensional Cross-Platform Planning for Complex Spinal Procedures
2017
STUDY DESIGN A feasibility study. OBJECTIVE To develop a method based on the DICOM standard which transfers complex 3-dimensional (3D) trajectories and objects from external planning software to any navigation system for planning and intraoperative guidance of complex spinal procedures. SUMMARY OF BACKGROUND DATA There have been many reports about navigation systems with embedded planning solutions but only few on how to transfer planning data generated in external software. MATERIALS AND METHODS Patients computerized tomography and/or magnetic resonance volume data sets of the affected spinal segments were imported to Amira software, reconstructed to 3D images and fused with magnetic reson…
Comparison of digital protocols for the measurement of peri-implant marginal bone loss
2018
Background The measurement of peri-implant marginal bone loss is currently carried out using digital methods of radiographic analysis assisted by various types of software. The purpose of this study was to compare the characteristics of three different softwares: specific radiology software for the development and visualization of radiological images in DICOM format (3Dicom Viewer®), advanced level software for professional editing of bitmap images (or raster graphics) (Adobe Photoshop®), and mid-level software for processing bitmap-type images, programmed in Java and in the public domain (ImageJ®). Material and Methods It was verified that the three softwares used are valid for the measure…
Visual knowledge processing in computer-assisted radiology: A consultation system
1992
This paper presents Visual Heuristics, a consultation system for diagnosis based on thorax radiograph recording. Visual Heuristics uses both prototypical representations of physiological and pathological states and reasoning aimed to infer conclusions from pathological or physiological conditions, establishing correspondences between pathological or physiological states and semantic descriptions of images. Images are assembled with groups of descriptors that guide the recognition process, achieving the possibility of comparisons with real images on the basis of 'expected' images. The system may be employed to generate a dynamic atlas that does not contain proper images, but generates them.
Visual Marker Guided Point Cloud Registration in a Large Multi-Sensor Industrial Robot Cell
2018
This paper presents a benchmark and accuracy analysis of 3D sensor calibration in a large industrial robot cell. The sensors used were the Kinect v2 which contains both an RGB and an IR camera measuring depth based on the time-of-flight principle. The approach taken was based on a novel procedure combining Aruco visual markers, methods using region of interest and iterative closest point. The calibration of sensors is performed pairwise, exploiting the fact that time-of-flight sensors can have some overlap in the generated point cloud data. For a volume measuring 10m × 14m × 5m a typical accuracy of the generated point cloud data of 5–10cm was achieved using six sensor nodes.
Augmented Reality Visualisation Concepts to Support Intraoperative Distance Estimation
2019
The estimation of distances and spatial relations between surgical instruments and surrounding anatomical structures is a challenging task for clinicians in image-guided surgery. Using augmented reality (AR), navigation aids can be displayed directly at the intervention site to support the assessment of distances and reduce the risk of damage to healthy tissue. To this end, four distance-encoding visualisation concepts were developed using a head-mounted optical see-through AR setup and evaluated by conducting a comparison study. Results suggest the general advantage of the proposed methods compared to a blank visualisation providing no additional information. Using a Distance Sensor concep…