Search results for "VOLTAGE"
showing 10 items of 934 documents
Uncertainty evaluation of a Backward/Forward Load Flow algorithm for a MV smart grid
2015
This paper presents the uncertainty evaluation of an innovative measurement algorithm for load flow analysis in MV distribution networks. The measurement procedure is based on Low Voltage (LV) load power measurements applied on a Backward/Forward (B/F) algorithm for the Load Flow (LF) resolution. Furthermore, in the procedure a three phase voltage measurement at the MV generating substation bus-bars is also considered. The accuracy analysis of the LF algorithm is performed in the case of a real load condition in the distribution grid of Ustica island, Italy. The analysis takes into account the uncertainty of the measurement instruments at the LV side of each secondary substation power trans…
A statistic approach of cables ageing in MV lines on thermal and electrical combined stress
2006
The paper introduces a methodology that through a probabilistic characterisation of load for MV network, and implementing a life model for combined electric and thermal stresses, simulates the process of ageing of the insulating materials evaluating the expected life time of the cable. Such evaluation is necessary to the possibility of assuming less restrictive thermal overloading limits on electrical cables, with the consequential increase on reserve that cables could offer. A numerical example is reported to better explain the methodology
Experimental study of low-voltage surge protection device response in realistic systems
2008
Experimental results on low-voltage surge protection under fast pulses in realistic wiring systems are presented. A fast voltage pulse generator is designed to provide fast voltage pulses with short steep fronts. The effective residual voltage of protected equipment is then investigated and compared with simulation results.
Grid synchronization of DC energy storage using Voltage Source Inverter with ZCD and PLL techniques
2015
To increase the penetration of renewable energy sources, a proper energy storage is required. In this context, there is a growing concern about the use of energy storage for overcoming the intermittency of renewable energy sources as well as in demand side management. In order to accomplish grid synchronization of energy storage, proper power conditioning devices are required. This paper analyses single phase grid synchronization of DC energy storage using MATLAB Simulink ® environment. The considered power conditioning device is a Voltage Source Inverter (VSI), which is controlled using two methods called (i) traditional Zero Crossing Detection (ZCD) technique and (ii) the phase detector b…
Narrowband power line communications for medium voltage smart grids
2014
The aim of the paper is to show how narrowband power line communications (NB-PLCs) can be a valid solution for medium voltage grids. Advantages and drawbacks of this solution are analyzed, starting from some experimental communication results, which were carried out on the medium power system networks of the islands of Ustica and Favignana, in the presence of the net voltage. Furthermore, some communication architectures and hardware prototypes based on NB-PLCs are proposed for different smart grids applications.
A back to back method for the temperature rise test of prefabricated substations: A case study
2015
In this work a back to back method is presented which allows to develop heating tests of prefabricated secondary substations with a limited number of supplying equipment (an induction regulator and a capacitor bank). The proposed method makes use of the transformer tap changers to create a voltage difference on the medium voltage side. In this way, only an adjunctive low voltage supply is needed. With the proposed test system, the heating tests are developed on a 1000 kVA prefabricated substation. Thanks to the experimental tests, the class of enclosure of the substation and the operating temperature and resistance of the power transformers are determined, according to the recommendations o…
Generalized PWM-VSI Control Algorithm Based on a Universal Duty-Cycle Expression: Theoretical Analysis, Simulation Results, and Experimental Validati…
2007
This paper presents a new approach in realizing various carrier-based pulsewidth-modulation techniques by a generalized control algorithm, which is referred to as the universal control algorithm and is obtained via unequal sharing of null states. The flexibility of such an approach allows one to easily and quickly control two-level inverters. Furthermore, this approach may be also extended with few changes to the control of multilevel inverters. The algorithm that is presented here for two-level voltage-source inverters (VSIs) also obtains efficient detection and management of both the linear and overmodulation ranges. In the overmodulation range, which is treated by using the alpha-beta co…
Evaluation of radiated EMI in 42 V vehicle electrical systems by FDTD simulation
2007
In this paper a full 3D numerical scheme, based on the finite difference time domain method, is used to predict the electromagnetic radiated interference generated by 42 V vehicle power electronic driven electrical loads. An experimental set-up has been arranged on purpose in order to validate the proposed simulation tool. To this aim, the features of a semi-anechoic electromagnetic chamber have been exploited in order to operate in a shielded test site for the measurement of near field radiated emissions. Two different three-dimensional geometrical configurations of realistic vehicle installations of the loads, are studied. A comparative analysis among measured and computed results is perf…
Impedance estimation of FEA's grid in fiji islands by V-I measurement by using the synchronous reference frame-PLL
2017
In recent years there has been a significant increase in distributed renewable energy generation feeding into the grid, with resulting detriment of the stability of the network, since present networks have not been designed for this purpose. To feed-in these renewable energy sources with minimum impact, it is essential to know a few grid parameters (voltage, current, grid impedance) at the point in which power supply is convenient. For this purpose in this paper an algorithm is proposed to obtain the estimated network impedance. This algorithm operates in time domain by a synchronous reference coordinate transformation, it requires only the measurement of the phase voltage with no-load and …
Hybrid passive and communications-based methods for islanding detection in medium and low voltage smart grids
2013
Islanding condition takes place when a distributed generator (DG) continues to power a part of the grid even if power from electric utility is no longer present. Adverse effects of islanding are power quality deterioration, grid-protection interference, equipment damage, and personnel safety hazards. For these reasons, DG systems must detect an islanding condition and immediately disconnect from the grid (anti-islanding protection). This paper proposes an hybrid solution, for both low voltage (LV) and medium voltage (MV) applications, which makes use of passive and communication-based methods for islanding detection. Among the existing communication technologies, the study is focused on pow…