Search results for "VOLUME"
showing 10 items of 1932 documents
Homeomorphisms of finite distortion: discrete length of radial images
2008
AbstractWe study homeomorphisms of finite exponentially integrable distortion of the unit ball Bn onto a domain Ω of finite volume. We show that under such a mapping the images of almost all radii (in terms of a gauge dimension) have finite discrete length. We also show that our dimension estimate is essentially sharp.
Draining and drying process development of the Tokamak Cooling Water System of ITER
2016
Abstract The ITER Organization (IO) developed a thermal-hydraulic (TH) model of the complex first wall and blanket (FW/BLK) cooling channels to determine gas flow rate and pressure required to effectively blow out the water in the FW/BLK. In addition, US ITER conducted experiments for selected geometries of FW/BLK flow channels to predict the blowout parameters. The analysis indicates that as low as 2 MPa of pressure difference over the blanket modules will ensure substantial evacuation of the water in blankets with just a few percent remaining in the blanket flow channels. A limited validation study indicates that the analysis yields less conservative results to compare against data collec…
Study of the column efficiency using gradient elution based on Van Deemter plots.
2018
Performance of chromatographic columns is of major importance in the development of more efficient separation methods. So far, a common practice is to study the column behavior in isocratic elution by modifying the flow rate and fitting the theoretical plate height values versus the mobile phase linear velocity, according to the Van Deemter equation. In this work, an approach is presented to extend the measurement of efficiency to linear gradient elution, where the mean retention factor is kept constant at each assayed flow. This avoids a possible source of uncertainty due to the change in the distribution equilibria profile, and makes the mean interactions with the stationary phase in grad…
Simultaneous optimization of mobile phase composition, column nature and length to analyse complex samples using serially coupled columns
2013
Abstract The combination of the selectivity of different columns serially coupled improves the separation expectancies with regard to the separation offered by each single column. In the reported approaches, either a pre-selected isocratic mobile phase composition or gradient program, giving rise to acceptable retention, is used. In previous work (JCA 1281 (2013) 94), we showed that the approach succeeds with conventional columns, assembled through zero-dead volume couplers. In this work, the simultaneous interpretive optimization of mobile phase composition and column nature and length, based on a limited number of experimental data, is demonstrated. This approach allows an impressive redu…
Prediction of Peak Shape and Characterization of Column Performance in Liquid Chromatography as a Function of Flow Rate
2015
Traditionally, column performance in liquid chromatography has been studied using information from the elution of probe compounds at different flow rates through van Deemter plots, which relate the column plate height to the linear mobile phase velocity. A more recent approach to characterize columns is the representation of the peak widths (or the right and left peak half-widths) for a set of compounds versus their retention times, which, for isocratic elution, give rise to almost linear plots. In previous work, these plots have been shown to facilitate the prediction of peak profiles (width and asymmetry) with optimization purposes. In this work, a detailed study on the dependence of the …
Vanadium Carbide Dissolution during Austenitisation of a Model Microalloyed FeCV Steel
2005
High performance commercial micro alloyed steels contain elements such as vanadium, which leads to a fine dispersion of vanadium carbide precipitates. The precipitation state, in terms of volume fraction and size distribution, plays a significant role in final mechanical properties of the material. Different austenitisation heat treatments were performed on a model ternary alloy FeCV. Precipitation states were characterised combining different experimental techniques. TEM was used to identify the chemical composition of observed precipitates. ICP mass spectroscopy was performed to measure the volume fraction of precipitates. The size distribution was studied by SEM. Results are characterist…
Nonlocal Second Order Vehicular Traffic Flow Models And Lagrange-Remap Finite Volumes
2011
In this paper a second order vehicular macroscopic model is derived from a microscopic car–following type model and it is analyzed. The source term includes nonlocal anticipation terms. A Finite Volume Lagrange–remap scheme is proposed.
Ventilation, oxidative stress and risk of brain injury in preterm newborn
2020
AbstractPreterm infants have an increased risk of cognitive and behavioral deficits and cerebral palsy compared to term born babies. Especially before 32 weeks of gestation, infants may require respiratory support, but at the same time, ventilation is known to induce oxidative stress, increasing the risk of brain injury. Ventilation may cause brain damage through two pathways: localized cerebral inflammatory response and hemodynamic instability. During ventilation, the most important causes of pro-inflammatory cytokine release are oxygen toxicity, barotrauma and volutrauma. The purpose of this review was to analyze the mechanism of ventilation-induced lung injury (VILI) and the relationship…
Color superposition: a new modality for contrast echocardiography.
1987
To improve the estimation of endocardial borders in echocardiography, a technique has been developed to combine images from contrasted and noncontrasted echocardiograms of the same heart-phase using a color superposition mode. This method allows both experienced as well as less experienced examiners to define the endocardial borders more reproducibly and objectively. This is achieved by displaying tissue structures as gray level images while the ventricular cavity is marked selectively by the color display of the contrast material zone. Results of volume estimations of the left ventricle by different examiners using several imaging modes including color superposition display are presented.
Hierarchical imaging and computational analysis of three-dimensional vascular network architecture in the entire postnatal and adult mouse brain
2021
The formation of new blood vessels and the establishment of vascular networks are crucial during brain development, in the adult healthy brain, as well as in various diseases of the central nervous system. Here, we describe a step-by-step protocol for our recently developed method that enables hierarchical imaging and computational analysis of vascular networks in postnatal and adult mouse brains. The different stages of the procedure include resin-based vascular corrosion casting, scanning electron microscopy, synchrotron radiation and desktop microcomputed tomography imaging, and computational network analysis. Combining these methods enables detailed visualization and quantification of t…