Search results for "VOLUME"
showing 10 items of 1932 documents
The MAST-FV/FE scheme for the simulation of thermohaline processes in variable density saturated porous media
2009
A novel methodology for the simulation of 2D thermohaline double diffusive processes, driven by heterogeneous temperature and concentration fields in variable-density satu- rated porous media, is presented. The stream function is used to describe the flow field and it is defined in terms of mass flux. The partial differential equations governing system is given by the mass conservation equation of the fluid phase written in terms of the mass- based stream function, as well as by the advection–diffusion transport equations of the contaminant concentration and of the heat. The unknown variables are the stream func- tion, the contaminant concentration and the temperature. The governing equatio…
The MAST-FV/FEM scheme for the simulation of thermohaline processes in density-variable saturated porous media
2008
Update on desiccant wheel model
2004
This short communication presents the update on the desiccant wheel models, developed earlier by the present authors. It is to be mentioned here that the psycrometric model presented earlier (Int. J. Energy Res., 2003; 27:17) is valid only for the desiccant wheel running with identical volume air-flows in supply and regeneration sides. However, when system runs with volume air flow ratio between supply and regeneration side (α), different from 1 (one), the model need further modifications. In the present work, correction factors were developed and incorporated in order to update the earlier model for predicting correctly the temperature and humidity of processed air at the outlet of desicca…
Rapid evaluation of ammonium in different rain events minimizing needed volume by a cost-effective and sustainable PDMS supported solid sensor.
2020
Abstract The presence of ammonium ion in rainwater is due to atmospheric processes which involve its scavenging from gas phase and particulate matter. The fractionated samplings of rainwater can provide information about these processes and their potential sources. However, only a low sample volume may be available, which constrained the analysis in general and more particularly in situ mode. For minimizing this limitation, this work proposes a polydimethylsiloxane (PDMS)-salicylate sensor that produces a color change. The embedding of solid reagents into PDMS was optimized. Good analytical characteristics (analysis time of 10 min, sample volume of 500 μL, limit of detection 0.03 μgmL−1) we…
Development and characterization of a thermal inkjet-based aerosol generator for micro-volume sample introduction in analytical atomic spectrometry
2011
A novel system for the introduction of liquid samples into analytical plasmas for atomic spectrometric analysis is presented in this manuscript for the first time. The proposed “drop-on-demand” (DOD) aerosol generator is based on the use of a modified thermal inkjet cartridge. This system employs a lab-built microcontroller, which allows accessing all parameters important for driving the dosing cartridge for the generation of pL-droplets from sample volumes in the μL range. The droplet generation frequency, thus the resulting liquid flow rate, is variable over a wide range from the generation of isolated droplets up to a theoretical flow rate of approximately 2 mL min−1, with parallel opera…
Sequential injection spectrophotometric determination of oxybenzone in lipsticks
2001
A sequential injection (SI) procedure for the spectrophotometric determination of oxybenzone in lipsticks is reported. The colorimetric reaction between nickel and oxybenzone was used. SI parameters such as sample solution volume, reagent solution volume, propulsion flow rate and reaction coil length were studied. The limit of detection was 3 microg ml(-1). The sensitivity was 0.0108+/-0.0002 ml microg(-1). The relative standard deviations of the results were between 6 and 12%. The real concentrations of samples and the values obtained by HPLC were comparable. Microwave sample pre-treatment allowed the extraction of oxybenzone with ethanol, thus avoiding the use of toxic organic solvents. E…
Determination of total arsenic in soft drinks by hydride generation atomic fluorescence spectrometry
2007
Abstract A highly sensitive and simple method has been developed for the determination of total arsenic, by continuous hydride generation and atomic fluorescence spectrometry (HGAFS), in refreshing drink samples as colas, teas and fruit juices. Samples were mixed with concentrated HCl and KI to obtain final concentrations of 2 mol l−1 and 1%, respectively. These solutions were aspirated and merged with a reducing NaBH4 3% (m/v) solution, with sample and NaBH4 flow rates of 12.5 and 1.5 ml min−1, respectively. The hydride generated in a 170 cm reaction coil was transported to the detector with an Ar flow of 400 ml min−1. The recovery values of added concentrations, from 0.1 to 0.9 ng ml−1, o…
Environmentally friendly analytical chemistry through automation: comparative study of strategies for carbaryl determination with p-aminophenol
1999
Abstract A flow system, based on multicommutation and binary sampling, has been developed for improving the automated spectrophotometric determination of carbaryl with p -aminophenol (PAP) in order to reduce the waste volume and to preserve the maximum analytical performance. The procedure, which was implemented employing a flow network obtained by nesting five, three-way solenoid valves controlled by means of a 386 microcomputer equipped with an electronic interface running software written in quick basic 4.5, provides a limit of detection of 26 μg l −1 , comparable to that obtained using a conventional flow injection (FIA) manifold and lower than that found by sequential injection analysi…
Some observations on the sensitivity of flow-injection techniques for atomic absorption spectrophotometry
1989
Abstract Different strategies for coupling flow-injection manifolds to atomic absorption spectrometers in order to obtain better sensitivity are compared. Using a T-connector interface, different carriers and flow compensation solvents have been assayed in an attempt to improve the sensitivity of flow-injection analysis. Manganese and copper determinations in sewage sludge have been used as a test system and the analytical parameters of both batch and flow-injection methods are compared.
Atomic fluorescence spectrometric determination of trace amounts of arsenic and antimony in drinking water by continuous hydride generation
1999
A highly sensitive and simple method has been developed for the determination of As(III), total As, Sb(III) and total Sb in drinking water samples by continuous hydride generation and atomic fluorescence spectrometry (HGAFS). For As determination, water samples aspirated in a carrier of 2 mol l(-1) HCl were merged with a reducing NaBH(4) 3%(m/v) solution, with sample and NaBH(4) flow rates of 12.5 and 1.5 ml min(-1) respectively. The hydride generated in a 170 cm reaction coil was transported to the detector with an Ar flow of 400 ml min(-1), and a limit of detection between 5 and 20 ng l(-1) was obtained. For Sb determination, 2.5 mol l(-1) HCl and 2%(m/v) NaBH(4) were employed, with respe…