Search results for "Validity."
showing 10 items of 867 documents
2020
Gait variability observed in step duration is predictive of impending adverse health outcomes among apparently healthy older adults and could potentially be evaluated using wearable sensors (inertial measurement units, IMU). The purpose of the present study was to establish the reliability and concurrent validity of gait variability and complexity evaluated with a waist and an ankle-worn IMU. Seventeen women (age 74.8 (SD 44) years) and 10 men (73.7 (4.1) years) attended two laboratory measurement sessions a week apart. Their stride duration variability was concurrently evaluated based on a continuous 3 min walk using a force plate and a waist- and an ankle-worn IMU. Their gait complexity (…
Deutschsprachige Validierung des Vertigo Handicap Questionnaire (VHQ) anhand einer Patientenstichprobe mit vestibulärem und somatoformem Schwindel
2010
The Vertigo Handicap Questionnaire (VHQ) by Yardley (1992) assesses physical and psychosocial impairments of vertigo or dizziness. Our study examines the structure, reliability, and aspects of validity of the German version of the VHQ. 98 vestibular vertigo syndromes vs. 90 patients with somatoform vertigo and dizziness were evaluated with the VHQ, symptom severity (VSS), distress (GSI), anxiety and depression (HADS), catastrophizing beliefs (ACQ), fear of body sensations (BSQ), and quality of life (SF-36). For diagnostic classification detailed clinical neurological, neuro-otological and psychosomatic testing were conducted. Principal components analysis identified two factors, which could…
Validation of motor and functional scales for the evaluation of adult patients with 5q spinal muscular atrophy
2021
ABSTRACTObjectiveTo assess in adult spinal muscular atrophy (SMA) patients the construct validity and responsiveness of several outcome measures.MethodsPatients older than 15 years and followed-up at least for 6 months, between October 2015 and August 2020, with one motor function scale (Hammersmith Functional Motor Scale Expanded, HFMSE; Revised Upper Limb module, RULM) in five referral centers were included. Bedside functional scales (Egen Klassification, EK2; Revised Amyotrophic Lateral Sclerosis Functional Rating Scale, ALSFRS-R) were also collected when available. Correlations and regression models were performed to evaluate the construct validity. The monthly slopes of change were use…
Factor structure, internal consistency and construct validity of the Sheehan Disability Scale in a Spanish primary care sample
2010
Rationale, aims and objectives The Sheehan Disability Scale (SDS) is a three-item instrument that measures disability in three inter-related domains: work, family life/home responsibilities and social/leisure activities. The main objective of the present study was to examine the factor structure, reliability and construct validity of the SDS in a wide Spanish sample of primary care (PC) patients. Methods One phase cross-sectional survey.Atotal of 3815 patients, aged 18 years or older attending PC for a medical visit, were interviewed between October 2005 and March 2006. The interviews included the Structured Clinical Interview for DSM-IVAxis I Disorders for depressive and anxiety disorders,…
Self‐management of immunomodulatory drug treatment in multiple myeloma patients
2019
Objective Immunomodulatory drugs (IMIDs: thalidomide, lenalidomide and pomalidomide) are widely used in patients with multiple myeloma (MM). The aim of our study was to validate a questionnaire to evaluate the self-capacity of MM patients to manage IMID treatment including side effects. Methods We used a method adapted from the recommendations of the European Organisation for Research and Treatment of Cancer (EORTC) to validate a French questionnaire for patients with MM treated with IMIDs. Results The face validity was evaluated in 15 patients and the construct validity in 56 patients. For discriminant validity, two groups were constituted by gender and depending on whether they had a prev…
Color-discrimination threshold determination using pseudoisochromatic test plates
2014
We produced a set of pseudoisochromatic plates for determining individual color-difference thresholds to assess test performance and test properties, and analyzed the results. We report a high test validity and classification ability for the deficiency type and severity level [comparable to that of the fourth edition of the Hardy–Rand–Rittler (HRR) test]. We discuss changes of the acceptable chromatic shifts from the protan and deutan confusion lines along the CIE xy diagram, and the high correlation of individual color-difference thresholds and the red–green discrimination index. Color vision was tested using an Oculus HMC anomaloscope, a Farnsworth D15, and an HRR test on 273 schoolchildr…
Listado de síntomas breve (short checklist of symptoms) in Argentinean adults: Psychometric study of its main clinical scales
2016
The main objective of this research was studying the psychometric properties of the Listado de síntomas breve (short checklist of symptoms; LSB-50) in a sample of 994 Argentinean adults (49.9% females; 50.1% males). Mean age was 40.66 years (standard deviation=17.01; Min=18; Max=89). This screening test has seven main clinical scales: hypersensitivity, obsessive-compulsive, anxiety, hostility, somatization, depression, and sleep disturbance. Pearson correlations indicated that all scales had positive and mostly moderate associations. The second order confirmatory factor analysis showed a good fit for a hierarchical model where all scales loaded in one major factor. Internal consistency by C…
Reliability and validity of a new accelerometer-based device for detecting physical activities and energy expenditure.
2018
Background Objective assessments of sedentary behavior and physical activity (PA) by using accelerometer-based wearable devices are ever expanding, given their importance in the global context of health maintenance. This study aimed to determine the reliability and validity of a new accelerometer-based analyzer (Fibion) for detecting different PAs and estimating energy expenditure (EE) during a simulated free-living day. Methods The study consisted of two parts: a reliability (n = 18) and a validity (n = 19) test. Reliability was assessed by a 45 min protocol of repeated sitting, standing, and walking (i.e., 3 × 15 min, repeated twice), using both Fibion and ActiGraph. Validity was assesse…
The vaccinaTion & Hpv Knowledge (THinK) questionnaire: a reliability and validity study on a sample of women living in Sicily (southern-Italy)
2019
Objective The aim of this study was to introduce the VaccinaTion & Hpv Knowledge (THinK) questionnaire to assess knowledge about human papillomavirus (HPV) and attitude to HPV-vaccination. Its reliability and validity was demonstrated in a sample of women living in Sicily (southern Italy). Methods A cross-sectional survey was conducted on a sample of 220 women at the “Paolo Giaccone” University Hospital in Palermo (Sicily), aged 18–61. Data were analyzed through Cronbach’s alpha and exploratory factor analysis, followed by a structural equation model with measurement component. The two-level data structure was explicitly considered. Results Three dimensions were found: “knowledge of HP…
Validity of the PHQ-9 and PHQ-2 to screen for depression in nationwide primary care population in Latvia
2018
Abstract Background Depression is highly underdiagnosed in primary care settings in Latvia. Screening for depression in primary care is potentially an efficient way to find undetected case s and improve diagnostics. We aimed to validate both a nine-item and two-item Patient Health Questionnaire (PHQ-9 and PHQ-2) in the Latvian and Russian languages in primary care settings using a representative sample in Latvia. Materials and methods The study was carried out within the framework of the National Research Program BIOMEDICINE to assess the prevalence of mental disorders at 24 primary care facilities. During a 1-week period, all consecutive adult patients were invited to complete the PHQ-9 an…