Search results for "Vascular Patency"
showing 10 items of 43 documents
Endovascular treatment options for complex abdominal aortic aneurysms
2015
Abstract Purpose To report short-term and midterm outcomes of endovascular aneurysm repair (EVAR) of complex aneurysms requiring revascularization of visceral arteries. Materials and Methods Prospective data were collected from patients deemed unsuitable for conventional EVAR and conventional surgery who were treated with different endovascular approaches according to the clinical presentation of the aneurysm. Custom-made fenestrated endovascular aneurysm repair (CM f-EVAR) was used in the elective setting, homemade fenestrated endovascular aneurysm repair (HM f-EVAR) or HM f-EVAR combined with chimney endovascular aneurysm repair (ch-EVAR) was used in the emergent setting in patients with …
Effectiveness of platinum wire microcoils for venous occlusion: A study on patients treated for venogenic impotence
1994
The purpose of this study was to determine the effectiveness of venous occlusions achieved by embolization with platinum microwire coils. Follow-up venographies in 19 patients, 1-20 months (average 8 months) after coil embolizations, were evaluated. Twenty-eight of 126 (22.2%) coil embolizations were found to be patent. Coils which had not formed or partially formed upon embolization had a patency/recanalization rate of 37.5% (12/32). Among coils which had formed nearly completely or completely only 16 of 95 (17%) showed venous patency. As coil embolization had been augmented by sclerotherapy in all patients, the effectiveness of long-term venous occlusion by platinum wire coils alone is pr…
A Multicenter Experience With a New Fenestrated-Branched Device for Endovascular Repair of Thoracoabdominal Aortic Aneurysms.
2018
To investigate the outcomes of patients who were treated for thoracoabdominal aortic aneurysms (TAAAs) using custom-made fenestrated-branched stent-grafts.A consecutive series of 108 patients (mean age 73.5 years; 73 men) with TAAA were treated with E-xtra Design Engineering customized fenestrated-branched stent-grafts between November 2011 and January 2017. Data on baseline characteristics, procedures, and clinical follow-up were collected from 6 regional European surgical centers for retrospective analysis of endoleaks, reinterventions, and target vessel patency. The median aneurysm diameter was 6.75 cm (range 5.5-13). The distribution of the TAAA according to the modified Crawford classi…
Periscope endograft technique to revascularize the left subclavian artery during thoracic endovascular aortic repair.
2013
To present early and midterm results of the periscope endograft (PG) technique to maintain left subclavian artery (LSA) blood flow in thoracic endovascular aortic repairs (TEVAR) involving zone 3.From April 2010 to January 2013, 14 consecutive high-risk patients (11 men; mean age 70±8 years, range 56-87) underwent TEVAR with the PG technique for 10 thoracic aortic aneurysms (TAA), 2 traumatic aortic ruptures, and 2 aortic dissections without a suitable landing zone (2 cm distal to the LSA). Five procedures were performed emergently for rupture (3 TAAs and the 2 trauma cases). Two patients had a periscope deployed in an aberrant right subclavian artery. The periscope endografts were sized 1 …
Graft patency and late outcomes for patients with ST-segment elevation myocardial infarction who underwent coronary surgery
2011
Objective: The aim of our study was to assess the long-term clinical outcomes and the grafts patency rates of patients with ST-segment elevation myocardial infarction (STEMI) who underwent urgent or emergency coronary artery bypass grafting (CABG). Materials: Participants in two previous studies comprising 207 STEMI patients undergoing on-pump (145 patients) or off-pump (62 patients) coronary artery bypass graft (CABG) surgery in our institution were prospectively followed to assess late mortality, graft patency, and major adverse cardiac-related event (MACE) rates. Graft patency was evaluated by multi-detector computed tomography angiography 64-slice scan. Mean times of graft implantation…
Mid-Term Results of Endovascular Aneurysm Sealing in the Treatment of Abdominal Aortic Aneurysm With Unfavorable Morphology.
2020
Purpose: To report mid-term results of endovascular aneurysm sealing (EVAS) of abdominal aortic aneurysms (AAA) deemed unsuitable for a standard endovascular aneurysm repair (EVAR). Methods: A prospectively maintained database of 42 patients with EVAR-unfavorable anatomy treated by EVAS combined with chimney grafts in case of the proximal AAA neck shorter than 5 mm was analyzed. Early outcomes included final angiographic result, intra- and early post-operative deaths, and complications. Mid-term outcomes included all-cause mortality (ACM), aneurysm-related mortality (ARM), patency of the stents, occurrence of endoleaks, serious complications and graft failures defined as the AAA growth of m…
Use of covered chimney stents for pararenal aortic pathologies is safe and feasible with excellent patency and low incidence of endoleaks.
2012
Background To present the clinical experience of consecutive series with use of balloon-expandable and self-expanding chimney endografts (balloon-expandable covered stent group [BECS] vs self-expanding covered stent group [SECS]) in the endovascular treatment of challenging aortic pathologies requiring renal and/or visceral revascularization. Methods Between January 2009 and May 2011, data for 37 high-risk patients from one center and 35 patients from another institution, with pararenal aortic pathologies treated by the chimney endovascular technique, were prospectively collected. The chimney-graft technique is based on the deployment of a covered or bare-metal stent parallel to the aortic …
Value of the deep femoral artery as alternative inflow source in infrainguinal bypass surgery.
2013
Background The purpose of this study was to analyze the long-term results of infrainguinal bypass surgery using the deep femoral artery (DFA) as the inflow source. Methods Between 1998 and 2011, 88 bypasses of the lower limb were placed in 86 patients (mean age 71 years) using the deep femoral artery as inflow. Patients' records were retrieved from a computerized database and analyzed retrospectively. Results Critical limb ischemia (rest pain/tissue loss) was the indication in the majority (87.5%) of cases. The distal anastomosis of the bypass grafts was located at the popliteal level in 32 cases and the tibial (pedal) level in 52 cases, respectively, with the autologous vein as conduit in …
The DETOUR procedure: no more need for conventional bypass surgery?
2018
Background Long segment occlusive disease in the superficial femoral artery remains a treatment challenge despite advances in open surgical and endovascular approaches. We report initial clinical results of an entirely new procedure to perform percutaneous femoro-popliteal bypass using the DETOUR System. First-in-human patients were performed in New Zealand from December 2013 to June 2014. After modifications to the technique and devices had significantly refined the procedure, the Detour I Trial commenced. Methods Review of initial results in the first five patients treated at a single site enrolled in IRB-approved, prospective clinical study using the DETOUR System. All patients signed in…
The Gore Hybrid Vascular Graft in renovisceral debranching for complex aortic aneurysm repair.
2016
Objective This study reports our initial experience with the Gore Hybrid Vascular Graft (GHVG; W. L. Gore & Associates, Flagstaff, Ariz) for staged hybrid open renovisceral debranching and endovascular aneurysm repair in patients affected by thoracoabdominal aortic aneurysms and pararenal abdominal aortic aneurysms (PAAAs). Methods Between December 2012 and December 2013, we analyzed outcomes of 13 patients who underwent open surgical debranching of renovisceral vessels for thoracoabdominal aortic aneurysm and PAAAs. All patients were considered at high risk for conventional surgery. Inclusion criterion was treatment by open surgical debranching of at least one visceral artery (renal artery…