Search results for "Velocimetry"
showing 10 items of 94 documents
Two-step cross correlation-based algorithm for motion estimation applied to fertilizer granules' motion during centrifugal spreading
2011
Imaging systems are progressing in both accuracy and ro- bustness, and their use in precision agriculture is increasing accordingly. One application of imaging systems is to understand and control the cen- trifugal fertilizing spreading process. Predicting the spreading pattern on the ground relies on an estimation of the trajectories and velocities of ejected granules. The algorithms proposed to date have shown low ac- curacy, with an error rate of a few pixels. But a more accurate estimation of the motion of the granules can be achieved. Our new two-step cross- correlation-based algorithm is based on the technique used in particle image velocimetry (PIV), which has yielded highly accurate…
Ultraviolet camera measurements of passive and explosive (Strombolian) sulphur dioxide emissions at Yasur volcano, Vanuatu
2020
Here, we present the first ultraviolet (UV) camera measurements of sulphur dioxide (SO2) flux from Yasur volcano, Vanuatu, for the period 6–9 July 2018. These data yield the first direct gas-measurement-derived calculations of explosion gas masses at Yasur. Yasur typically exhibits persistent passive gas release interspersed with frequent Strombolian explosions. We used compact forms of the “PiCam” Raspberry Pi UV camera system [1,2] powered through solar panels to collect images. Our daily median SO2 fluxes ranged from 4 to 5.1 kg s−1, with a measurement uncertainty of −12.2% to +14.7%, including errors from the gas cell calibration drift, uncertainties in plume direction and distance, and…
Discussion on 'Estimating depth-averaged velocities in rough channels'
2002
In this short communication the four estimate criteria of the depth-averaged local velocity proposed by Byrd et al. (Earth Surface Processes and Landforms, 2000, Vol. 25, pp. 167-173) are compared both with the three-point method of Bathurst and with the average velocity obtained by integrating the velocity profile (FPa2) suggested by Ferro and Pecoraro (Water Resources Research, 2000, vol. 36, pp. 2761-2770). The comparison was carried out using 84 velocity profiles measured by an acoustic Doppler velocimeter in a rectangular flume with a gravel bed. Copyright © 2002 John Wiley and Sons, Ltd.
A physical model for the interaction between unsaturated soils and retaining structures
2020
Temporary and permanent retaining structures interact with soils that are usually in unsaturated conditions. In this work, a 1g-scale physical model is presented to investigate the interactions between retaining walls and unsaturated soils. The physical model is equipped with a water-filled hydraulic cylinder connected to a pressure-volume controller to measure the horizontal component of the later earth thrust and high capacity tensiometers to measure soil matric suction. A system of low-friction linear guideways has been installed at the base of the wall-model. The failure surface is observed through a 3 cm thick glass wall on one side of the container. A series of images are acquired dur…
Optical Methods for River Monitoring: A Simulation-Based Approach to Explore Optimal Experimental Setup for LSPIV
2021
Recent advances in image-based methods for environmental monitoring are opening new frontiers for remote streamflow measurements in natural environments. Such techniques offer numerous advantages compared to traditional approaches. Despite the wide availability of cost-effective devices and software for image processing, these techniques are still rarely systematically implemented in practical applications, probably due to the lack of consistent operational protocols for both phases of images acquisition and processing. In this work, the optimal experimental setup for LSPIV based flow velocity measurements under different conditions is explored using the software PIVlab, investigating perfo…
ESRA19-0692 Which preoperative tests before regional anaesthetic procedures?
2019
As we know, any regional anaesthesia technique stays under failure risks. What anaesthetists have to know about the regional block before let the surgeons start after regional anaesthesia? There are few positions which should be confirmed by tests. Firstly, detect the onset of successful sensitive, motor and sympathetic block. Secondly, confirm the correct area of the regional block. Furthermore, the anaesthetist should understand if the regional block performed under deep sedation or general anaesthesia will be effective also after the surgery. What we have to remember and what we need to check for this reason? Pain is subjective phenomenon. Are we determined as dependent on the patient‘s …
Noninvasive diagnostic techniques of port wine stain.
2021
Port-wine stain (PWS) is a benign capillary malformation that most commonly occurs in the head and neck. It is present at birth and progresses over time. It is formed by progressive dilatation of post-capillary venules and is associated with hypertrophy and nodularity with increasing age, leading to cosmetic disfigurement and psychological aggravation. It is caused by genetic mosaicism in GNAQ and GNA11 genes. Histopathology is the gold standard for assessment of PWS but it is invasive and may cause scarring. Inadequate characterization of the lesions may predispose to inadequate treatment protocols as well as higher treatment dosages. Clinical evaluation of treatment efficacy is subjective…
Laser Doppler Scanning: How Many Measurements are Required to Assess Regional Cerebral Blood Flow?
2000
This study was initiated to determine the optimal number of measuring sites necessary to estimate regional cerebral blood flow (CBF) under pathophysiological conditions.
Microvascular blood flow changes of the abductor pollicis brevis muscle during sustained static exercise
2021
A practical assessment of the general health and microvascular function of the palm muscle, abductor pollicis brevis (APB), is important for the diagnosis of different conditions. In this study, we have developed a protocol and a probe to study microvascular blood flow using near-infrared diffuse correlation spectroscopy (DCS) in APB during and after thumb abduction at 55% of maximum voluntary contraction (MVC). Near-infrared time resolved spectroscopy (TRS) was also used to characterize the baseline optical and hemodynamic properties. Thirteen (n=13) subjects were enrolled and subdivided in low MVC (N=6, MVC<2.3 kg) and high MVC (N=7, MVC≥2.3 kg) groups. After ruling out significant cha…
Variations in acoustical beam properties of intracoronary Doppler catheters.
1993
The limitations of coronary angiography in assessing the functional significance of coronary obstructions is well known. While the critical variable of coronary blood flow cannot be readily measured, intraluminal Doppler sonography offers useful related functional information on blood flow velocity. In order to fully evaluate Doppler signals it is essential to have exact knowledge of the transducer transmission characteristics and of the ultrasound beam topology. In an experimental set-up, the transmitter-receiver characteristics of five commonly used Doppler catheters were investigated. In comparing the beam characteristics we found inhomogeneities in the lateral beam spread. At a penetrat…