Search results for "Veneer"
showing 7 items of 27 documents
Influence of low concentration acid treatment on lithium disilicate core/veneer ceramic bond strength
2013
Objective: This study evaluated the influence of low concentration acid treatment on the shear bond strength between lithium disilicate (LD) infrastructure and veneering porcelain. The surface morphology characteristic after this acid treatment was also examined. Study Design: LD reinforced ceramic cylinders (n=10) (IPS e.max Press, Ivoclar-Vivadent, Schaan, Liechtenstein) were treated (LD-treated) with a low concentration acid solution (Invex Liquid – Ivoclar-Vivadent, Schaan, Liechtenstein) or not treated with the acid solution (LD-untreated). They were veneered with a glass ceramic (IPS e.max Ceram, Ivoclar-Vivadent, Schaan, Liechtenstein). A metal ceramic group (CoCr) was tested as cont…
Le superfici murarie a vista: restauri a Palermo e a Rodi (fine se. XIX- prima metà sec. XX)
2018
Il saggio indaga la particolare tecnica di restauro delle superfici murarie lasciate a vista dell’architettura medievale considerando alcuni casi nella città di Palermo e di Rodi in Grecia (fine del sec. XIX - prima metà del sec. XX). In particolare, dopo avere eliminato gli strati di intonaco, anche quelli coevi alla costruzione, l’architettura medievale era sottoposta ad interventi di rifacimento delle superfici sia interne che esterne, mediante la tecnica dell’”impiallicciatura”, cioè ricostruendo i filari dei conci delle murature con materiale simile per natura, dimensioni e colore, o estraendo il concio degradato, resecando la parte ammalorata e ricollocandolo nella muratura. Questa op…
Clinical outcomes of veneered zirconia anterior partial fixed dental prostheses: A 12-year prospective clinical trial
2019
Abstract Statement of problem Anterior veneered zirconia partial fixed dental prostheses (FDPs) have substituted for metal-ceramic to improve esthetics and biocompatibility. However, the material is susceptible to aging or hydrothermal degradation and to chipping of the feldspathic veneer. Whether these susceptibilities limit the clinical performance of anterior veneered zirconia FPDs is unclear. Purpose The purpose of this prospective clinical study was to analyze the mechanical and biologic behavior of zirconia partial FDPs in the anterior region over a 12-year follow-up period. Material and methods Twenty-seven 3- to 6-unit FDPs fabricated from zirconia veneered with feldspathic porcelai…
Long-term fracture load of all-ceramic crowns: Effects of veneering ceramic thickness, application techniques, and cooling protocol
2020
Made available in DSpace on 2021-06-25T10:46:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2020-11-01 Background: To evaluate, in vitro, the effects of the cooling protocol, application technique, and veneering ceramic thickness on the fracture resistance of ceramic crowns with Y-TZP frameworks. Material and Methods: 80 frameworks were made from zirconia by the CAD/CAM technique and divided into 8 groups (n = 10) according to the factors: “application technique” (stratified-L and pressed -P), “thickness” (1 mm and 2 mm), and “cooling protocol” (slow-S and fast-F) of the feldspathic veneering ceramic. After, all crowns were cemented over G10 preparations with resin cement (Panavia F, …
Post-fatigue fracture resistance of metal core crowns: press-on metal ceramic versus a conventional veneering system
2014
Background The aim of this in vitro study was to compare the mechanical failure behavior and to analyze fracture characteristics of metal ceramic crowns with two veneering systems – press-on metal (PoM) ceramic versus a conventional veneering system – subjected to static compressive loading. Material and Methods Forty-six crowns were constructed and divided into two groups according to porcelain veneer manufacture. Group A: 23 metal copings with porcelain IPS-InLine veneering (conventional metal ceramic). Group B: 23 metal copings with IPS-InLine PoM veneering porcelain. After 120,000 fatigue cycles, the crowns were axially loaded to the moment of fracture with a universal testing machine. …
A comparative evaluation of shear bond strength between feldspathic porcelain and lithium di silicate ceramic layered to a zirconia core? An in vitro…
2020
Background The bond strength between the zirconia core and ceramic veneer is the weakest component in the layered structure. Delamination of veneering ceramic is reported as one of the most frequent problems associated with Veneered Zirconia restorations. The aim of this study is to compare the shear bond strength of lithium di silicate porcelain to that of feldspathic porcelain on a zirconia Substrate. Material and Methods Two groups (group A and B) of zirconia blocks with each group having 20 samples were fabricated according to Schmitz Schulmeyer method. Group A (n =20 ) samples were veneered with feldspathic veneering porcelain and Group B (n=20) samples were veneered with heat pressed …
A New System for Choosing the Form and Size of Complete Denture Anterior Teeth
2016
Introduction: In the absence of pre-extraction records, the choice of the size an form of anterior complete denture teeth can be extremely subjective. Several clinical and statistical parameters are usually used for choosing the correct size and form of the complete denture anterior teeth. Clinical Innovation: The technique consists of a system that allows the dentist to choose and, if necessary, easily change the dental mold during maxillomandibular recording session. The unique feature of the system is that six teeth of each mold are represented by veneers, which are connected to each other on the lingual surface by a fiber that allows each veneer some degree of movement. Discussion: This…