Search results for "Vessel"
showing 10 items of 751 documents
Reinterpreting the Magnetic Resonance Signs of Hemodynamic Impairment in the Brains of Multiple Sclerosis Patients From the Perspective of a Recent D…
2010
Multiple sclerosis patients examined with perfusion magnetic resonance (MR) imaging techniques have been found to have patterns of abnormal blood flow. These include prolonged mean transit time, a trend toward decreased cerebral blood flow in the area of plaques, and decreased cerebral blood flow and prolonged mean transit time within normal-appearing white matter. In-creased cerebral blood flow and volume and decreased mean transit time (compared with the baseline values before the relapse) were found to precede the development of plaques. In addition, susceptibility-weighted imaging utilizing deoxyhemoglobin as the contrast has revealed that venous blood in cerebral veins of multiple scle…
EphrinB2 controls vessel pruning through STAT1-JNK3 signalling
2014
Angiogenesis produces primitive vascular networks that need pruning to yield hierarchically organized and functional vessels. Despite the critical importance of vessel pruning to vessel patterning and function, the mechanisms regulating this process are not clear. Here we show that EphrinB2, a well-known player in angiogenesis, is an essential regulator of endothelial cell death and vessel pruning. This regulation depends upon phosphotyrosine-EphrinB2 signalling repressing c-jun N-terminal kinase 3 activity via STAT1. JNK3 activation causes endothelial cell death. In the absence of JNK3, hyaloid vessel physiological pruning is impaired, associated with abnormal persistence of hyaloid vessel…
Critical single proximal left arterial descending coronary artery stenosis to mimic chronic myocardial ischemia: a new model induced by minimal invas…
2008
<i>Background/Aims:</i> The present report examines a new pig model for progressive induction of high-grade stenosis, for the study of chronic myocardial ischemia and the dynamics of collateral vessel growth. <i>Methods:</i> Thirty-nine Landrace pigs were instrumented with a novel experimental stent (GVD stent) in the left anterior descending coronary artery. Eight animals underwent transthoracic echocardiography at rest and under low-dose dobutamine. Seven animals were examined by nuclear PET and SPECT analysis. Epi-, mid- and endocardial fibrosis and the numbers of arterial vessels were examined by histology. <i>Results:</i> Functional analysis showed a…
The use of Endurant stent-graft for abdominal aortic aneurysm: the story about extension of instruction for use with persistent good results of stent…
2012
The Endurant stent-graft (Medtronic, Inc., Minneapolis, MN, USA) is a latest generation device for the treatment of abdominal aortic aneurysm. The idea behind designing such a graft came from the intention to broad the instruction for use (IFU) and to enable it to treat more challenging anatomy including the 10mm neck lengths, and more severe suprarenal and infrarenal angulations. Endurant stent-graft has active fixation through suprarenal stent with anchoring pins to provide migration resistance, optimized heights of stents and spacing between them for improved flexibility and conformability, low-profile delivery system with hydrophilic coating and controlled simple deployment mechanism. S…
Defining a reduced volume zone for the simulation of burst test on a composite pressure vessels
2018
International audience; A Fibre-Break Model (FBM) developed at Mines ParisTech can predict the burst pressure of high pressure composite vessels. This model uses random values of fibre strength at each Gauss point of the considered vessels meshed with finite element (FE). However, previous studies has determined the optimum FEs to be used on real-scale structures (0.1 mm x 0.1 mm x 8 mm). A simple calculation shows that, on a real-scale pressure vessel, this induces a gigantic number of FEs, hence the extensive computation time. To overcome this problem, the integral range method is proposed to find a reduced volume zone of the vessels, on which an equivalent calculation can be made and giv…
Filter Bank: a Directional Approach for Retinal Vessel Segmentation
2017
It is well known that retinal diseases are sometimes identified by tortuosity of the vessels, presence of exudates and hemorrhages while lesions of tissues are associated to diabetic retinopathy, retinopathy of prematurity and more general cerebrovascular problems. One of the main issues in this research field is detecting small curvilinear structures, thus the aim of this contribution is to introduce a non-supervised and automated methodology to detect features such as curvilinear structures in retinal images. The core of the proposed methodology consists in using an approach that resembles the “a trous” wavelet algorithm. With respect to the standard Gabor analysis our methodology is base…
Semi-automated evaluation tool for retinal vasculopathy.
2009
The ocular fundus is the only area of human body where vascular system is visible using relatively simple instrumentation. Furthermore, there is medical suggestive evidence of a direct relationship between certain measures of vascular characteristics in the ocular fundus (arteriolar and venular calibers and focal arteriolar narrowing) and cardiovascular diseases. In order to establish such relationship on sound statistical basis a method must be provided to measure the needed values in an easy, yet precise and repeatable way. This paper presents a system to assist physicians in signaling and storing the data associated to signs of vascular deterioration and vascular calibers in non-mydriati…
Progress in EU Breeding Blanket design and integration
2018
Abstract In Europe (EU), in the frame of the EUROfusion consortium activities, four Breeding Blanket (BB) concepts are being developed with the aim of fulfilling the performances required by a near-term fusion power demonstration plant (DEMO) in terms of tritium self-sufficiency and electricity production. The four blanket options cover a wide range of technological possibilities, as water and helium are considered as possible coolants and solid ceramic breeder in combination with beryllium and PbLi as tritium breeder and neutron multipliers. The strategy for the BB selection and operation has to account for the challenging schedule of the EU DEMO, the ambitious operational requirements of …
Confocal laser endomicroscopy for gastrointestinal diseases.
2008
Confocal laser endomicroscopy enables in vivo microscopy of the mucosal layer of the gastrointestinal tract with subcellular resolution during ongoing endoscopy. Endomicroscopy opens the door to immediate tissue and vessel analysis. Different types of diseases can be diagnosed with optical surface and subsurface analysis. Analysis of the in vivo microarchitecture can be used for targeting biopsies to relevant areas, and subsurface imaging can unmask microscopic diseases or bacterial infection. Molecular imaging is becoming feasible, which will enable new indications in gastrointestinal endoscopy. This article reviews the current and rapidly expanding clinical data on endomicroscopy and give…
Prevalence of anatomical variants and coronary anomalies in 543 consecutive patients studied with 64-slice CT coronary angiography
2008
The aim of our study was to assess the prevalence of variants and anomalies of the coronary artery tree in patients who underwent 64-slice computed tomography coronary angiography (CT-CA) for suspected or known coronary artery disease. A total of 543 patients (389 male, mean age 60.5 +/- 10.9) were reviewed for coronary artery variants and anomalies including post-processing tools. The majority of segments were identified according to the American Heart Association scheme. The coronary dominance pattern results were: right, 86.6%; left, 9.2%; balanced, 4.2%. The left main coronary artery had a mean length of 112 +/- 55 mm. The intermediate branch was present in the 21.9%. A variable number …