Search results for "Vessel"
showing 10 items of 751 documents
Long-term results of simplified frozen elephant trunk technique in complicated acute type A aortic dissection: A case-control study.
2016
Aim To describe the long-term experience of a simplified frozen elephant trunk technique (sFETT) used in complicated acute type A aortic dissection (AAAD) treatment. Methods and results Between January 2001 and December 2012, 34 patients (mean age 59.9 ± 11.0 years) with complicated AAAD (DeBakey I) underwent an emergency surgery including sFETT. sFETT consisted in gluing the dissected aortic arch wall layers with gelatine-resorcinol adhesive and video-assisted antegrade open arch aortic stent-graft deployment in the arch or proximal descending aorta. In addition to sFETT, the aortic root was addressed with standard techniques. A 30-day mortality was 14.7% (five patients) due to bleeding (1…
Mid-term Results of Chimney and Periscope Grafts in Supra-aortic Branches in High Risk Patients
2017
Purpose Report mid-term outcomes of thoracic endovascular aneurysm repair (TEVAR) with chimney and periscope grafts (CPG) in supra-aortic branches (SAB). Methods Retrospective analysis, from October 2009 to May 2014, of patients with aneurysms requiring TEVAR with zone 0/1/2 proximal landing in association with at least one CPG in the SAB. All patients were considered at high risk for conventional surgery. Peri-operative mortality and morbidity, retrograde type A dissection, maximum aortic transverse diameter (TD) and its post-operative evolution, endoleak, survival, freedom from cardiovascular re-interventions, and CPG freedom from occlusion during the follow-up were analysed. Results Fort…
Hybrid Endograft Solution for Complex Iliac Anatomy
2010
The purpose of this study was to evaluate single-center results with selective use of Gore Excluder limbs (W.L. Gore & Associates, Flagstaff, AZ) in a Cook Zenith body (Cook Inc, Bloomington, IN) for elective endovascular abdominal aortic aneurysm (AAA) repair. A prospectively held database for patients with AAA, who were treated endovascularly between March 1999 and July 2008, was queried for patients treated with a Cook Zenith body and one or two Gore Excluder limbs. Indication, technical success, late limb occlusion, and disconnection were evaluated. From 276 patients who were treated with a Zenith body, 29 underwent repair with hybrid graft components with, in total, 41 Gore Exclud…
Physical training and hypertension have opposite effects on endothelial brain-derived neurotrophic factor expression
2013
AIMS: Changes in circulating brain-derived neurotrophic factor (BDNF) levels were reported in patients with or at risk for cardiovascular diseases associated with endothelial dysfunction, suggesting a link between BDNF and endothelial functionality. However, little is known on cardiovascular BDNF. Our aim was to investigate levels/localization, function, and relevance of cardiovascular BDNF. METHODS AND RESULTS: BDNF levels (western blotting) and localization (immunostaining) were assessed in the heart and aorta from rats with impaired (spontaneously hypertensive rats [SHR]), normal (Wistar Kyoto rats [WKY]), and improved (SHR and WKY subjected to physical training) endothelial function. BD…
Peroperative Intravascular Ultrasound for Endovascular Aneurysm Repair versus Peroperative Angiography: A Pilot Study in Fit Patients with Favorable …
2020
The aim of this study was to compare intravascular ultrasound (IVUS) assistance for endovascular aortic aneurysm repair (EVAR) to standard assistance by angiography.From June 2015 to June 2017, 173 consecutive patients underwent EVAR. In this group, 69 procedures were IVUS-assisted with X-ray exposure limited to completion angiography for safety purposes because an IVUS probe does not yet incorporate a duplex probe (group A), and 104 were angiography-assisted procedures (group B). All IVUS-assisted procedures were performed by vascular surgeons with basic duplex ultrasound (DUS) training. The primary study endpoints were mean radiation dose, duration of fluoroscopy, amount of contrast media…
Anastomotic Pseudoaneurysm Complicating Renal Transplantation: Treatment Options
2010
Introduction: Anastomotic pseudoaneurysm following renal transplantation is uncommon. Indications for repair, treatment options and outcomes remain controversial. Report: We present 6 renal transplant recipients with large anastomotic pseudoaneurysms. Five of the patients underwent open repair while one had a stent-grafting and delayed transplant nephrectomy for a ruptured pseudoaneurysm. A transplant nephrectomy was needed in all cases but one. Arterial reconstruction enabled limb salvage in all cases. One patient died of sepsis postoperatively. No patient presented late infection, failure of vascular reconstruction, nor pseudoaneurysm recurrence. Conclusions: Surgical excision of anastomo…
Collected Transatlantic Experience From the PERICLES Registry: Use of Chimney Grafts to Treat Post-EVAR Type Ia Endoleaks Shows Good Midterm Results
2018
Purpose: The aim of this retrospective analysis was to evaluate the performance of the chimney (ch) technique in the treatment of type Ia endoleaks after standard endovascular aneurysm repair (EVAR). Methods: Between January 2008 and December 2014, 517 chEVAR procedures were performed in 13 US and European vascular centers (PERICLES registry). Thirty-nine patients (mean age 76.9±7.1 years; 33 men) were treated for persistent type Ia endoleak and had computed tomography angiography or magnetic resonance angiography follow-up at >1 month. Endurant abdominal stent-grafts were used in the 20 cases. Single chimney graft placement was performed in 18 (46%) patients and multiple in 21 (54%). O…
Single-centre experience and preliminary Results of intravascular ultrasound in endovascular aneurysm repair
2019
Background Intravascular ultrasound (IVUS) has been introduced as diagnostic adjunct to provide new insights into the diagnosis and therapy of vascular disease. Herein, we compared the outcomes of conventional endovascular aneurysm repair (EVAR) and EVAR with IVUS in patients presenting with infrarenal abdominal aortic aneurysm using a propensity-matched cohort. Methods From May 2013 to August 2017, 221 patients were retrospectively analyzed. Of that, 122 patients were eligible for inclusion and underwent propensity score matching. Perioperative mortality and morbidity, renal function impairment, endoleak incidence, mean contrast medium usage, operative time, radiation exposure (including f…
Fenestrated Stent Grafting for Short-necked and Juxtarenal Abdominal Aortic Aneurysm
2010
Objectives: To present an 8-year clinical experience in the endovascular treatment of short-necked and juxtarenal abdominal aortic aneurysm (AAA) with fenestrated stent grafts. Methods: At our tertiary referral centre, all patients treated with fenestrated and branched stent grafts have been enrolled in an investigational device protocol database. Patients with short-necked or juxtarenal AAA managed with fenestrated endovascular aneurysm repair (F-EVAR) between November 2001 and April 2009 were retrospectively reviewed. Patients treated at other hospitals under the supervision of the main author were excluded from the study. Patients treated for suprarenal or thoraco-abdominal aneurysms wer…
Results of chimney endovascular aneurysm repair as used in the PERICLES Registry to treat patients with suprarenal aortic pathologies
2020
Background: The prevailing evidence calls for using chimney/snorkel endovascular repair (ch-EVAR) with one or two chimney grafts. No studies up to now focus on its applicability and results for the treatment of suprarenal aortic pathologies (SRAP). Hence, we evaluated the clinical and radiologic results of ch-EVAR treatment for SRAP placing three or more chimney grafts within the PERICLES Registry. Methods: Data from 517 patients suffering complex aortic pathologies treated by ch-EVAR between 2008 and 2014 at 13 European and U.S. centers were retrospectively reviewed and analyzed. Results: Sixty-seven ch-EVAR-treated patients (12.9% of the entire PERICLES cohort) presented SRAP (83.5% elect…