Search results for "Vessel"

showing 10 items of 751 documents

Laboratorijas trauku un iekārtu katalogi Latvijas Ķīmijas vēstures muzeja krājumā

2020

The library of the Latvian Chemistry History Museum contains catalogs of laboratory vessels and equipment from 16 different manufacturers, which were published in the period from 1900 to 1961. The article explores the manufacturers of laboratory vessels and equipment, as well as provides information on the history of product catalogs and scientific equipment catalogs.

:HUMANITIES and RELIGION::History and philosophy subjects::History subjects::History of technology and industry [Research Subject Categories]katalogilaboratory equipmentLatvian Chemistry History Museumlaboratorijas iekārtaslaboratorijas traukilaboratory vesselsLatvijas Ķīmijas vēstures muzejscatalogs
researchProduct

CT angiography for the assessment of EVAR complications : a pictorial review

2022

Aortic aneurysm; Blood vessel prosthesis implantation; Endovascular procedures Aneurisma aórtico; Implantación de prótesis de vasos sanguíneos; Procedimientos endovasculares Aneurisma aòrtic; Implantació de pròtesis de vasos sanguinis; Procediments endovasculars Endovascular aneurysm repair (EVAR) is a minimally invasive treatment proposed as an alternative to open repair in patients with abdominal aortic aneurysms. EVAR consists in a stent-graft placement within the aorta in order to exclude the aneurysm from arterial circulation and reduce the risk of rupture. Knowledge of the various types of devices is mandatory because some stents/grafts are more frequently associated with complication…

:intervenciones quirúrgicas::procedimientos quirúrgicos cardiovasculares::procedimientos quirúrgicos vasculares::procedimientos endovasculares [TÉCNICAS Y EQUIPOS ANALÍTICOS DIAGNÓSTICOS Y TERAPÉUTICOS]:Cardiovascular Diseases::Vascular Diseases::Aneurysm::Aortic Aneurysm::Aortic Aneurysm Abdominal [DISEASES]Aortic aneurysmR895-920:diagnóstico::técnicas y procedimientos diagnósticos::diagnóstico por imagen::interpretación de imágenes asistida por ordenador::tomografía computarizada por rayos X::angiografía por tomografía computarizada [TÉCNICAS Y EQUIPOS ANALÍTICOS DIAGNÓSTICOS Y TERAPÉUTICOS]:Otros calificadores::Otros calificadores::/diagnóstico por imagen [Otros calificadores]:enfermedades cardiovasculares::enfermedades vasculares::aneurisma::aneurisma de la aorta::aneurisma de la aorta abdominal [ENFERMEDADES]Blood vessel prosthesis implantation:Surgical Procedures Operative::Cardiovascular Surgical Procedures::Vascular Surgical Procedures::Endovascular Procedures [ANALYTICAL DIAGNOSTIC AND THERAPEUTIC TECHNIQUES AND EQUIPMENT]Medical physics. Medical radiology. Nuclear medicineVasos sanguinis - CirurgiaEndovascular procedureEndovascular procedures:Diagnosis::Diagnostic Techniques and Procedures::Diagnostic Imaging::Image Interpretation Computer-Assisted::Tomography X-Ray Computed::Computed Tomography Angiography [ANALYTICAL DIAGNOSTIC AND THERAPEUTIC TECHNIQUES AND EQUIPMENT]cardiovascular systemRadiology Nuclear Medicine and imagingAbdominalStentsAngiografiacardiovascular diseasesComputed tomography angiography:Other subheadings::Other subheadings::/diagnostic imaging [Other subheadings]Educational ReviewAneurisma abdominal - Imatgeria
researchProduct

Periscopes, chimneys, sandwich and VORTEC to facilitate abdominal and thoracoabdominal aortic aneurysm repair

2012

The VORTEC (VIABAHN open revascularization technique) and the chimney graft technique are tools with which to maintain or restore blood flow to the aortic branches and can be used intentionally or as a bailout procedure in open surgery or endovascular procedures. VORTEC is a stent graft-based vascular connection technique that achieves end-to-end anastomosis configuration; it is especially useful when the traditional suture technique proves (can be) cumbersome. It is also a speedy tool with virtually no blood flow interruption and no anastomotic bleeding, and patency rates compare favorably with sutured anastomosis. The chimney/periscope, as well as the sandwich graft technique (CHIMPES), i…

Abdominal aorta Thoracic aorta Aortic aneurysm Blood vessel prosthesis Endovascular procedures
researchProduct

Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study

2018

[EN] Anatomically based procedures to ablate atrial fibrillation (AF) are often successful in terminating paroxysmal AF. However, the ability to terminate persistent AF remains disappointing. New mechanistic approaches use multiple-electrode basket catheter mapping to localize and target AF drivers in the form of rotors but significant concerns remain about their accuracy. We aimed to evaluate how electrode-endocardium distance, far-field sources and inter-electrode distance affect the accuracy of localizing rotors. Sustained rotor activation of the atria was simulated numerically and mapped using a virtual basket catheter with varying electrode densities placed at different positions withi…

Ablation TechniquesNormalization propertyTime FactorsPhysiologymedicine.medical_treatmentAction Potentials02 engineering and technology030204 cardiovascular system & hematologylaw.invention0302 clinical medicineModelslawHeart RateMedicine and Health SciencesMapping cathetersCardiac Atrialcsh:QH301-705.5Numerical AnalysisEcologyRotor (electric)HeartAblationElectrophysiologyComputational Theory and Mathematicsmedicine.veinModeling and SimulationRotorsPhysical SciencesInferior Vena CavaEngineering and TechnologyAnatomyBasket catheterArrhythmiaInterpolationResearch ArticleBiotechnologyMaterials scienceCatheters0206 medical engineeringPhase (waves)CardiologyInferior vena cavaModels BiologicalMembrane PotentialImaging phantomVeinsTECNOLOGIA ELECTRONICA03 medical and health sciencesCellular and Molecular NeuroscienceAblation Techniques; Action Potentials; Atrial Fibrillation; Computational Biology; Computer Simulation; Heart Atria; Heart Conduction System; Heart Rate; Humans; Models Biological; Time FactorsHeart Conduction SystemPhase analysisGeneticsmedicineHumansComputer SimulationHeart AtriaMolecular BiologyEcology Evolution Behavior and SystematicsMechanical EngineeringComputational BiologyBiology and Life SciencesBiological020601 biomedical engineeringAtrial fibrillationInterpolationlcsh:Biology (General)Cardiovascular AnatomyBlood VesselsMedical Devices and EquipmentMathematicsBiomedical engineeringEndocardium
researchProduct

Accurate estimation of retinal vessel width using bagged decision trees and an extended multiresolution Hermite model.

2012

We present an algorithm estimating the width of retinal vessels in fundus camera images. The algorithm uses a novel parametric surface model of the cross-sectional intensities of vessels, and ensembles of bagged decision trees to estimate the local width from the parameters of the best-fit surface. We report comparative tests with REVIEW, currently the public database of reference for retinal width estimation, containing 16 images with 193 annotated vessel segments and 5066 profile points annotated manually by three independent experts. Comparative tests are reported also with our own set of 378 vessel widths selected sparsely in 38 images from the Tayside Scotland diabetic retinopathy scre…

Accurate estimationComputer scienceStability (learning theory)Decision treeHealth Informaticscomputer.software_genreSensitivity and SpecificityPattern Recognition AutomatedSet (abstract data type)Parametric surfaceImage Interpretation Computer-AssistedHumansRadiology Nuclear Medicine and imagingFluorescein AngiographyHermite polynomialsDiabetic RetinopathySettore INF/01 - InformaticaRadiological and Ultrasound TechnologyReproducibility of ResultsRetinal VesselsImage EnhancementComputer Graphics and Computer-Aided DesignData setComputer Vision and Pattern RecognitionData miningRetinal images Vessel width Multiresolution Hermite model Ensembles of bagged decision trees Medical image analysiscomputerAlgorithmsTest dataRetinoscopyMedical image analysis
researchProduct

Impact of combinatory growth factor application on rabbit Achilles tendon injury with operative versus conservative treatment: A pilot study

2009

Acute Achilles tendon (AT) rupture is a common injury with a comparatively high complication rate. Presently, surgical treatments compete with nonoperative treatment modalities. The aim of this study was to elucidate the possible beneficial effects of short-term combinatory application of growth factors on tendon healing during operative or conservative treatment. In this controlled laboratory study, the left ATs of 40 adult New Zealand White rabbits were transected and either sutured or treated conservatively. Half of the animals from each treatment modality group repetitively received a mixture of VEGF165, bFGF, and rPDGF which was administered peritendineally. The left legs were immobili…

Achilles tendonmedicine.medical_specialtybusiness.industryGrowth factormedicine.medical_treatmentGeneral MedicineSurgeryNonoperative treatmentConservative treatmentmedicine.anatomical_structureAchilles tendon injuryGeneticsmedicineMarginal impactbusinessTendon healingBlood vesselInternational Journal of Molecular Medicine
researchProduct

Automatic detection and classification of retinal vascular landmarks

2014

The main contribution of this paper is introducing a method to distinguish between different landmarks of the retina: bifurcations and crossings. The methodology may help in differentiating between arteries and veins and is useful in identifying diseases and other special pathologies, too. The method does not need any special skills, thus it can be assimilated to an automatic way for pinpointing landmarks; moreover it gives good responses for very small vessels. A skeletonized representation, taken out from the segmented binary image (obtained through a preprocessing step), is used to identify pixels with three or more neighbors. Then, the junction points are classified into bifurcations or…

Acoustics and UltrasonicsComputer scienceMaterials Science (miscellaneous)General MathematicsPreprocessorRadiology Nuclear Medicine and imagingComputer visionretinal vessel landmark points retinal vessel structure classificationRepresentation (mathematics)Instrumentationlcsh:R5-920PixelSettore INF/01 - Informaticabusiness.industryBinary imagelcsh:Mathematicslcsh:QA1-939retinal vessel structure classificationSignal ProcessingComputer Vision and Pattern RecognitionArtificial intelligencebusinessPrecision and recallretinal vessel landmark pointslcsh:Medicine (General)Biotechnology
researchProduct

Cardiac Computed Tomography Angiography Follow-Up of Resorbable Magnesium Scaffolds.

2021

Abstract Introduction An ancillary advantage of bioresorbable scaffolds is the possibility of non-invasive imaging assessment of the treated coronary segment. Cardiac computed tomography angiography (CCTA) studies of resorbable magnesium scaffolds (RMS) are scarce. Methods In this collaborative, international study, nine patients who had an RMS implanted underwent CCTA as part of follow-up assessment. Core-lab blinded quantitative and qualitative assessment was performed by an independent CCTA investigator. Results Eight studies were amenable for quantitative analysis, and the blinded CT investigator successfully located and evaluated patency of RMS in all cases. The CCTA follow-up in-scaff…

Acute coronary syndromeComputed Tomography AngiographyLate lossCoronary Artery Disease030204 cardiovascular system & hematologyCoronary Angiography03 medical and health sciences0302 clinical medicineCardiac computed tomography angiographyFibrous plaqueMedicineHumansMagnesium030212 general & internal medicinebusiness.industryGeneral Medicinemedicine.diseaseStenosisDiameter stenosisCoronary vesselCardiology and Cardiovascular MedicineNuclear medicinebusinessTomography X-Ray ComputedBioresorbable scaffoldFollow-Up StudiesCardiovascular revascularization medicine : including molecular interventions
researchProduct

Three-dimensional analysis of tumour vascular corrosion casts using stereoimaging and micro-computed tomography

2009

Objective: In order to perform effective translational research for cancer therapy, we need to employ preclinical models which reflect the clinical situation. The purpose of this study was to quantitatively compare the vascular architecture of human colorectal cancer and experimental tumour models to determine the suitability of animal models for vascular studies and antivascular therapy.Methods: In this study we investigated the three-dimensional properties of colonic tumour vasculature in both human clinical tissues (normal mucosa control [n = 20], carcinoma [n = 20] and adenoma In = 61) and murine colorectal xenografts (LS147T [n = 6] and SW1222 [n = 6]). Scanning Electron Microscope Ste…

AdenomaMalePathologymedicine.medical_specialtyX-ray microtomographyAdenomaColonColorectal cancerAngiogenesisTransplantation HeterologousMice NudeCorrosion CastingBiochemistryArticleMiceangiogenesisImaging Three-DimensionalmikrotomografiaIntestinal mucosaRenal cell carcinomaCell Line TumorNeoplasmsstereoimagingmedicineCarcinomaAnimalsHumansmicrovascular architectureIntestinal Mucosamicro-computed tomographybusiness.industryCarcinomaverisuoniston mikrorakennestereokuvausX-Ray MicrotomographytortuositeettiCell Biologymedicine.diseaseangiogeneesikorroosiovalucorrosion castingTransplantationMicrovesselsMicroscopy Electron ScanningFemaletortuosityColorectal NeoplasmsCardiology and Cardiovascular MedicinebusinessMicrovascular Research
researchProduct

Evaluation of the stromal vascular fraction of adipose tissue as the basis for a stem cell-based tissue-engineered vascular graft

2017

Abstract Objective One of the rate-limiting barriers within the field of vascular tissue engineering is the lengthy fabrication time associated with expanding appropriate cell types in culture. One particularly attractive cell type for this purpose is the adipose-derived mesenchymal stem cell (AD-MSC), which is abundant and easily harvested from liposuction procedures. Even this cell type has its drawbacks, however, including the required culture period for expansion, which could pose risks of cellular transformation or contamination. Eliminating culture entirely would be ideal to avoid these concerns. In this study, we used the raw population of cells obtained after digestion of human lipo…

Adult0301 basic medicinePathologymedicine.medical_specialtyTime FactorsCellular differentiationMyocytes Smooth MusclePopulationAdipose tissueCell Separation030204 cardiovascular system & hematologyMesenchymal Stem Cell TransplantationMuscle Smooth VascularArticleBlood Vessel Prosthesis Implantation03 medical and health sciences0302 clinical medicineLipectomyCell MovementBlood vessel prosthesisAnimalsHumansMedicineAorta AbdominaleducationCells CulturedBioprosthesiseducation.field_of_studyTissue EngineeringTissue Scaffoldsbusiness.industryAngiotensin IIMesenchymal stem cellCell DifferentiationMesenchymal Stem CellsAnatomyStromal vascular fractionAngiotensin IIBlood Vessel ProsthesisPhenotype030104 developmental biologyAdipose TissueRats Inbred LewFemaleSurgeryStromal CellsStem cellbusinessCardiology and Cardiovascular Medicine
researchProduct