Search results for "Vision disorder"

showing 10 items of 66 documents

Iris Claw Phakic Intraocular Lens for High Myopia

1997

ABSTRACT BACKGROUND: The implantation of a WorstFechner iris claw intraocular lens (IOL) is one of the surgical procedures used for the correction of high myopia. This technique reduces myopia with stähle refractive results; however, its potential long-term risks have not been evaluated. We report results in 94 eyes with a minimum follow -up of 3 years. METHODS: We studied 94 eyes of 62 patients with myopia 5= -7.00 diopters (D) who underwent Worst-Fechner IOL implantation. Lens decentration, permeability of the blood-aqueous barrier by iris angiography, and changes in corneal endothelial density were analyzed. RESULTS: Mean follow-up time was 48.9 months (range 36 to 72 mo). Three years af…

AdultMaleRefractive errormedicine.medical_specialtyTime FactorsVisual acuitygenetic structuresEye diseasemedicine.medical_treatmentVisual AcuityIrisEmmetropiaIntraocular lensRefraction OcularPhakic intraocular lensVision disorderPostoperative ComplicationsOphthalmologyMyopiamedicineHumansDioptreAgedRetrospective StudiesLenses Intraocularbusiness.industryEndothelium CornealMiddle Agedmedicine.diseaseeye diseasesOphthalmologyTreatment OutcomeFemaleSurgerysense organsmedicine.symptombusinessFollow-Up StudiesJournal of Refractive Surgery
researchProduct

Long-term results of surgical treatment of high myopia with Worst-Fechner intraocular lenses

1995

Abstract This retrospective study evaluated the results in 90 eyes that had a minus-power anterior chamber intraocular lens implanted to correct high myopia. Preoperative myopia ranged from −7.00 to −24.00 D. Postoperative spherical equivalent was −0.50 D; 80.5% of eyes were within 1.00 D of emmetropia. Two years postoperatively, no cataract formation, retinal detachment, glaucoma, or significant endothelial damage had occurred. We conclude that minus-power lenses can rapidly, safely, and predictably correct high myopia in phakic patients.

AdultMaleRefractive errormedicine.medical_specialtygenetic structuresAnterior ChamberEye diseasemedicine.medical_treatmentVisual AcuityEmmetropiaGlaucomaIntraocular lensProsthesis DesignVision disorderPostoperative ComplicationsOphthalmologyMyopiamedicineHumansLongitudinal StudiesAgedRetrospective StudiesLenses Intraocularbusiness.industryRetinal detachmentRetrospective cohort studyMiddle AgedPrognosismedicine.diseaseeye diseasesSensory SystemsOphthalmologyFemaleSurgerysense organsmedicine.symptombusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

Excimer laser photorefractive keratectomy for high myopia

1995

Abstract One hundred and thirty-three eyes of 103 patients had photorefractive keratectomy with a slit scan mode excimer laser for myopia ranging from −6.00 to −22.00 diopters (D). The epithelium was removed with 20% ethanol, and the ablation was done with a tapered profile surrounding the optical zone. Patients were divided into two groups based on preoperative myopia: Group A, −6.00 D to −12.00 D (88 eyes); Group B, −12.50 D to −22.00 D (45 eyes). In Group A, mean preoperative refraction was −9.59 ± 1.79 D. Mean postoperative refraction was −0.29 ± 1.47 D at one month, −0.85 ± 1.68 D at three months, −1.17 ± 2.04 D at six months, and −0.56 ± 0.74 D at one year. Anterior stromal haze was g…

AdultMaleRefractive errormedicine.medical_specialtygenetic structuresCorneal Stromamedicine.medical_treatmentEye diseaseVisual AcuityRefraction OcularExcimerPhotorefractive KeratectomyEpitheliumCorneaVision disorderCorneal OpacityOphthalmologyMyopiamedicineHumansIntraocular PressureDioptreExcimer laserbusiness.industryMiddle AgedPrognosismedicine.diseaseAblationeye diseasesSensory SystemsPhotorefractive keratectomyOphthalmologyFemaleLasers ExcimerSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Prevalence of corneal astigmatism before cataract surgery.

2008

To analyze the prevalence and presentation patterns of corneal astigmatism in cataract surgery candidates.University of Valencia, Valencia, Spain.Refractive and keratometric values were measured before surgery in patients having cataract extraction. Descriptive statistics of refractive and keratometric cylinder data were analyzed and correlated by age ranges.Refractive and keratometric data from 4,540 eyes of 2,415 patients (mean age 60.59 years +/- 9.87 [SD]; range 32 to 87 years) differed significantly when the patients were divided into 10-year subsets. There was a trend toward less negative corneal astigmatism values, except the steepest corneal radius and the J(45) vector component, in…

AdultMaleRefractive errormedicine.medical_specialtygenetic structuresmedicine.medical_treatmentEye diseaseIntraocular lensCataract ExtractionAstigmatismCorneal DiseasesVision disorderAge DistributionCorneaOphthalmologymedicinePrevalenceHumansProspective StudiesAgedAged 80 and overbusiness.industryAstigmatismCataract surgeryMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structureSpainOptometrySurgeryFemalesense organsmedicine.symptombusinessCorneal astigmatismJournal of cataract and refractive surgery
researchProduct

Endothelial study of iris-claw phakic lens: four year follow-up.

1998

Abstract Purpose: To study quantitative and morphometric endothelial changes in phakic eyes implanted with the Worst iris-claw lens to correct high myopia. Setting: Department of Ophthalmology, University Hospital “La Fe”, Valencia, Spain. Material and Methods: This retrospective study involved 111 phakic eyes (73 patients) implanted with the Worst iris-claw lens. Noncontact specular microscopy and computer-assisted analysis was performed preoperatively and 6 months and 1, 2, 3, and 4 years postoperatively. Results: The mean cell loss was 3.85% at 6 months, 6.59% at 1 year, 9.22% at 2 years, 11.68% at 3 years, and 13.42% at 4 years. At 2 years, the hexagonality and coefficient variation in …

AdultMaleReoperationmedicine.medical_specialtyRefractive errorVisual acuitygenetic structuresAnterior Chambermedicine.medical_treatmentEye diseaseCorneal TouchVisual AcuityIrisIntraocular lensCell CountPhakic intraocular lensCorneal DiseasesVision disorderPostoperative ComplicationsLens Implantation IntraocularOphthalmologyCorneaMyopiaMedicineHumansCell SizeRetrospective Studiesbusiness.industryEndothelium CornealMiddle Agedmedicine.diseaseeye diseasesSensory SystemsSurgeryOphthalmologymedicine.anatomical_structureSurgeryFemalesense organsmedicine.symptombusinessFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Flicker Defined Form Perimetry in Glaucoma Suspects with Normal Achromatic Visual Fields

2014

To evaluate if repeated flicker-defined form (FDF) perimetry can detect visual field (VF) defects in glaucoma suspects with normal findings in achromatic standard automated perimetry (SAP).Patients with optic nerve heads (ONHs) or retinal nerve fiber layer (RNFL) findings clinically suspicious for glaucoma and normal SAP were enrolled. Patients underwent VF testing with FDF perimetry (Heidelberg Edge Perimetry, HEP) at two consecutive visits (HEP I and HEP II) and confocal scanning laser ophthalmoscopy with the Heidelberg Retina Tomograph (HRT). Abnormal HEP was defined by cluster-point analysis (CPA) and by the HEP specific glaucoma hemi-field test (GHT). Results were compared with an age-…

AdultMaleRetinal Ganglion Cellsmedicine.medical_specialtygenetic structuresOptic DiskVision DisordersVisual AcuityNerve fiber layerGlaucomalaw.inventionTonometry OcularCellular and Molecular Neurosciencechemistry.chemical_compoundNerve FiberslawOphthalmologymedicineHumansProspective StudiesIntraocular PressureHeidelberg retina tomographOptic Nerve Headsbusiness.industryGlaucomaRetinalMiddle Agedmedicine.diseaseeye diseasesSensory SystemsVisual fieldConfocal scanning laser ophthalmoscopyOphthalmologyEarly Diagnosismedicine.anatomical_structurechemistryAchromatic lensVisual Field TestsFemaleOcular Hypertensionsense organsVisual FieldsbusinessCurrent Eye Research
researchProduct

Prevalence of visual problems in a rural population of Kenya

2012

AdultMaleRural PopulationVision DisordersVisual AcuityGeneral MedicineRefraction OcularKenyaOphthalmologyGeographyPrevalenceHumansFemaleSocioeconomicsDeveloping CountriesRural populationVisually Impaired PersonsActa Ophthalmologica
researchProduct

Evaluation of Physiological Parameters on Discomfort Glare Thresholds Using LUMIZ 100 Tool

2021

Purpose To assess the links between discomfort glare sensitivity and physiological factors such as eye biometry, refraction, skin phototype, age, and gender among a large sample of healthy human subjects. Methods A total of 489 participants who were 20 to 70 years old (241 men, 248 women) underwent discomfort glare threshold measurements via the LUMIZ 100. Eye biometry and optical quality were measured using a Zeiss IOLMaster 700 biometer and i.Profiler aberrometer. Iris color, skin tone, age, gender, eyeglasses use, chronotype, fatigue level, self-evaluation of light sensitivity, and time spent outdoors were determined. Statistical analysis was carried out using nonparametric Mann–Whitney …

AdultMalediscomfortiris colormedicine.medical_specialtyBiometrygenetic structuresPhotophobiaPopulationVision DisordersBiomedical EngineeringFrequency of usepupilAudiologyArticleIris colorYoung AdultHumansMedicineeducationFatigueAgededucation.field_of_studyLight sensitivitysunglasses usebusiness.industryskin toneGlare (vision)ChronotypeglareMiddle AgedOptical qualityOphthalmologyEyeglasseschronotypeFemalehealthy populationmedicine.symptomlightbusinessTranslational Vision Science & Technology
researchProduct

Blue-yellow deficiency in workers exposed to low concentrations of organic solvents

1997

Objectives: To evaluate the effects of low concentrations of organic solvents on color vision. Methods: Color vision was examined in 24 workers exposed to mixtures of solvents and in 24 control subjects. Exposure to mixtures was below the threshold-limit values. Color vision ability was assessed using the Ishihara plates (to screen for congenital dyschromatopsia), the Farnsworth panel D-15 test, the Lanthony desaturated panel D-15 test, and the Standard Pseudoisochromatic Plates part 2 (SPP2 test). Results: The comparatively less sensitive Farnsworth panel D-15 test failed to show any difference between the groups, but the Lanthony panel D-15 desaturated test as well as the SPP2 test showed…

AdultMalegenetic structuresbusiness.industryColor visionOrganic solventLow dosePublic Health Environmental and Occupational HealthColor Vision DefectsControl subjectseye diseasesVision disorderLogistic ModelsCase-Control StudiesOccupational ExposureSolventsHumansMedicineOccupational exposureFood sciencemedicine.symptombusinessDyschromatopsiaVolume concentrationPsychophysiologyInternational Archives of Occupational and Environmental Health
researchProduct

Diseño de una nueva prueba para medir la función de sensibilidad al contraste con iPad

2015

[EN] Purpose: To introduce a new application (ClinicCSF) to measure Contrast Sensitivity Function (CSF) with tablet devices, and to compare it against the Functional Acuity Contrast Test (FACT). Methods: A total of 42 subjects were arranged in two groups of 21 individuals. Different versions of the ClinicCSF (.v1 and .v2) were used to measure the CSF of each group with the same iPad and the results were compared with those measured with the FACT. The agreements between ClinicCSF and FACT for spatial frequencies of 3, 6, 12 and 18 cycles per degree (cpd) were represented by Bland---Altman plots. Results: Statistically significant differences in CSF of both groups were found due to the change…

AdultMalemedia_common.quotation_subjectVision DisordersVisual performanceFACTDesempeño visualCycles per degreeContrast SensitivityYoung Adultlcsh:OphthalmologyStatisticsHumansContrast (vision)lcsh:QC350-467Tablet devicesDiagnosis Computer-AssistedSensitivity (control systems)Simulationmedia_commonContrast sensitivity functionDispositivos de tabletaVision TestsMiddle AgedFunctional acuity contrast testConfidence intervalTest (assessment)Función de sensibilidad al contrasteiPadlcsh:RE1-994Computers HandheldFISICA APLICADAOriginal ArticleFemaleSpatial frequencyPsychologyEFAClcsh:Optics. LightOptometry
researchProduct