Search results for "Visual Acuity"
showing 10 items of 456 documents
Stereoacuity with balanced presbyopic contact lenses.
2010
Our aim was to evaluate near stereoacuity with the balanced Proclear Multifocal simultaneous vision contact lens. Twenty-five presbyopic subjects were fitted binocularly with the Proclear Multifocal contact lens and with distance contact lenses combined with reading spectacles, which served as controls. After one month, stereoacuity was measured using the vectographic Titmus and Random dot stereotests and the Howard-Dolman (HD) apparatus under photopic conditions (85 cd/m(2) ) at 40 cm. Binocular high-contrast visual acuities (BHCVA) at distance and near were examined. For the multifocal group, mean stereoacuity with the Howard-Dolman method was 22.40 ± 8.23 seconds of arc. Using the Titmus…
Refractive lens exchange with a multifocal diffractive aspheric intraocular lens
2012
PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients ha…
Contrast sensitivity loss in the peripheral visual field following laser in situ keratomileusis.
2007
We report a case of contrast sensitivity loss in the peripheral visual field following laser in situ keratomileusis (LASIK). A 50-year-old white man was referred to us for differences in visual perception in the peripheral field between the right eye, which had had LASIK, and the left eye, which was emmetropic. Linear meridional static perimetry was carried out in the 0- to 180-degree meridian using a Goldmann perimeter to assess the peripheral perimetric thresholds. There was a statistically significantly marked increased threshold in contrast sensitivity in the nasal and temporal fields from 40 degrees of eccentricity in the LASIK eye compared with that in the emmetropic eye. Eyes treated…
Visual performance comparison between contact lens-based pinhole and simultaneous vision contact lenses.
2011
Background The aim was to evaluate the visual performance provided with a contact lens-based pinhole design against a simultaneous vision multifocal contact lens. Methods In a cross-over study at the University of Valencia, 22 presbyopic patients were evaluated using an artificial pupil fitted on the non-dominant eye and the simultaneous vision PureVision Multifocal contact lenses. After one month of contact lens wear, binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance contrast sensitivity, binocular near contrast sensitivity, and stereoacuity were measured, under photopic conditions (85 cd/m2). In addition, binocular distance vis…
Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction.
2014
Purpose: To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC) on visual performance. Methods: This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an artificial pupil contact lens in the nondominant eye and a CBMCLC. After a month of lens wear, the binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance, and near contrast sensitivity and near stereoacuity (NSA) were measured under photopic conditions (85 cd/m2). Moreover, BDVA and binocular distance contrast sensitivity were …
Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens
2007
To determine whether pupil size is correlated with visual acuity and contrast sensitivity at all distances in eyes with an apodized diffractive intraocular lens (IOL).Private Clinic, Oviedo, Spain.Six months after surgery, the best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m2) and mesopic (5 cd/m2) conditions were measured in 670 eyes of 335 consecutive patients who had implantation of the AcrySof ReSTOR Natural IOL (SN60D3, Alcon). Pupil diameters in distance vision were measured using a pupillometer.The logMAR best corrected distance acuity was significantly better with …
Bilateral implantation of the Acri.LISA bifocal intraocular lens in myopic eyes.
2009
Purpose To asses visual quality after bilateral implantation of the Acri.LISA 366D intraocular lens (IOL) (Carl Zeiss Meditec) in patients with high and low–moderate myopia. Methods A total of 304 eyes of 152 patients had bilateral implantation of the Acri.LISA 366D IOL. The patients were divided into 2 groups: low–moderate myopia (IOL power from 15 to 20.5 D) and high myopia (IOL power from 0 to 14.5 D). Monocular and binocular best-corrected distance visual acuity (BCVA) and best distance-corrected near visual acuity (BCNVA), binocular best distance-corrected intermediate visual acuity (BCIVA), and distance contrast sensitivity (OS) under photopic (85 cd/m2) and mesopic (5 cd/m2) conditio…
Dexamethasone for unresponsive diabetic macular oedema: optical coherence tomography biomarkers
2019
Purpose: To analyse the effects of intravitreal dexamethasone implant (DEX) in patients with diabetic macular oedema (DME) unresponsive to ranibizumab treatment, in relation to the inflammatory optical coherence tomography (OCT) retinal features, subfoveal neuroretinal detachment (SND) and hyperreflective retinal spots (HRS). Methods: Patients with DME poorly responsive to three injections of ranibizumab were treated with DEX. Best-corrected visual acuity (BCVA) and central macula thickness (CMT, measured by Spectralis SD-OCT) were assessed at baseline and at 1, 3, and 6 months. Results: Overall, 44 eyes were included in the study. In the whole group, mean BCVA (baseline 51.5 ± 8.3 letters)…
DEXAMETHASONE INTRAVITREAL IMPLANT VS RANIBIZUMAB IN THE TREATMENT OF MACULAR EDEMA SECONDARY TO BRACHYTHERAPY FOR CHOROIDAL MELANOMA
2017
PURPOSE To evaluate the efficacy of an intravitreal dexamethasone (Dex) implant 0.7 mg compared with intravitreal ranibizumab (Ra) for the treatment of radiation maculopathy with macular edema secondary to plaque brachytherapy in choroidal melanoma. METHODS Eight patients were treated with intravitreal Ra, and eight patients received the Dex intravitreal implant. Visual acuity and foveal thickness were evaluated using spectral domain optical coherence tomography. RESULTS The mean calculated irradiation to the fovea and mean times from brachytherapy to maculopathy development did not differ significantly between groups. In the Ra group, a mean 7.8 ± 3.9 injections were given and the mean fol…
Stereoacuity with simultaneous vision multifocal contact lenses.
2010
Our purpose was to evaluate near stereoacuity (SA) with Focus Progressives and PureVision Multifocal simultaneous vision contact lenses. In a cross-over study design, 20 presbyopic subjects were fitted with either the Focus Progressives or PureVision Multifocal lenses. After 1 month, SA was measured with the vectographic Titmus, Random dot stereotests, and the Howard-Dolman apparatus under photopic conditions (85 lux) at 40 cm. Binocular high-contrast visual acuity at distance and near was examined. Subjects were then refitted with the alternative correction and the procedure was repeated. Mean SA with the Focus Progressive was 21 +/- 7 sec arc, 54 +/- 17 sec arc, and 51 +/- 21 sec arc, wit…