Wavelength dependence of visual acuity in goldfish.
2003
Visual acuity was measured in a two-choice training experiment with food reward. Four goldfish were trained to select a homogeneously illuminated testfield when a high-contrast grating (transparency) was shown for comparison at the second testfield. Measurements were performed for white and monochromatic testfield illuminations in the light adapted state. Fourteen wavelengths between 404 nm and 683 nm were tested. For each wavelength (and white light) the testfield intensity was determined for which spatial resolution was highest. Between 446 nm and 683 nm maximal values of 2.0 cycles/deg (corresponding to a visual acuity of 15' of arc) were found. At 404 nm and in the ultraviolet resolutio…
Contact lenses: do they really change the opticalperformance?
1996
Abstract In this investigation the quality of two types of optical correction, hydrogel contact lenses and ophthalmic lenses, wascompared by measuring the modulation transferfunction (MTF) of the correcting lens plus visual optics system using an objective method. A merit function was defined in order to allow the direct comparison between the optical performance with the two corrections. A study on 10 subjects was undertaken, measuring the MTF of both corrections by using the double pass method. The results show that the optical quality of contact lenses was higher than that with ophthalmic lenses. The contrast sensitivity function (CSF) and visual acuity (VA) were determined as subjective…
Erhöhte Schwellen für die Detektion von Phasenunterschieden in musterinduzierten Flimmerfarben bei Patienten mit Glaukom
1994
BACKGROUND: Pattern-induced flicker-colors are subjective colors produced by rotating disks with black-and-white arcs. Changing the direction of rotation results in a different color. Small variations in the temporal sequence (phase differences) of the black-and-white pattern cause the colors to vary and can be perceived as color differences. PATIENTS AND METHODS: We investigated the thresholds for such phase differences in healthy (n = 11) and in glaucomatous (n = 19) eyes. Acuity and color vision were tested and in patients static visual field perimetry (Octopus G1) was carried out. The disks used for producing the pattern-induced flicker-colors were viewed from a distance of 2 m and had …
Implantable collamer lens and femtosecond laser for myopia: comparison using an adaptive optics visual simulator.
2014
Purpose: To compare optical and visual quality of implantable collamer lens (ICL) implantation and femtosecond laser in situ keratomileusis (F-LASIK) for myopia. Methods: The CRX1 adaptive optics visual simulator (Imagine Eyes, Orsay, France) was used to simulate the wavefront aberration pattern after the two surgical procedures for -3-diopter (D) and -6-D myopia. Visual acuity at different contrasts and contrast sensitivities at 10, 20, and 25 cycles/degree (cpd) were measured for 3-mm and 5-mm pupils. The modulation transfer function (MTF) and point spread function (PSF) were calculated for 5-mm pupils. Results: F-LASIK MTF was worse than ICL MTF, which was close to diffraction-limited MT…
Myopic astigmatism correction: comparison of a Toric Implantable Collamer Lens and a bioptics technique by an adaptive optics visual simulator.
2013
Purpose To compare the optical and visual quality of a simulated Toric Implantable Collamer Lens (TICL) and a bioptics technique to treat high myopic astigmatism. Methods An adaptive optics visual simulator was used to simulate the vision after TICL implantation and a bioptics procedure from the wavefront aberration pattern for moderate and high-myopic astigmatism. Visual acuity (VA) at different contrasts and contrast sensitivity (CS) at 10, 20 and 25 cycles degree−1 were measured for 3 and 5-mm pupils. Modulation Transfer Function (MTF) and Point Spread Function (PSF) were calculated for a 5-mm pupil. Results At a 3-mm pupil we only found statistically significant differences in VA betwee…
Diffractive corneal inlay for presbyopia
2017
[EN] A conceptually new type of corneal inlays for a customized treatment of presbyopia is presented. The diffractive inlay consists on a small aperture disc having an array of micro-holes distributed inside the open zones of a Fresnel zone plate. In this way, the central hole of the disc lets pass the zero order diffraction and produces an extension of the depth of far focus of the eye, while the diffracted light through the holes in the periphery produce the near focus. Additionally, the micro-holes in the inlay surface fulfill the essential requirement of allowing the flow of nutrients through it to the cells of the corneal stroma. Theoretical and optical-bench experimental results for t…
Merits of vision in presence of light scattering using Tiffen ProMist filters
2020
Light scattering caused by Tiffen ProMist photographic filters of various grades at different laser radiation 640 nm, 532 nm and 405 nm was objectively studied and compared. The lack of removal of speckles from the scene of laser radiation scattering did not allow an accurate assessment of the effect of scattering on the decrease in image contrast. Subjective deterioration in visual acuity using various contrast optotypes and contrast sensitivity was assessed by scattering induction using filters up to grade #5. Vision contrast sensitivity diminishes within all studied spatial frequency range 0.5-18 cpd. The degradation of the impact factor to visual acuity without scattering filters when t…
Optical and visual quality comparison of implantable Collamer lens and laser in situ keratomileusis for myopia using an adaptive optics visual simula…
2012
Purpose. To compare optical and visual quality of the implantable Collamer lens (ICL) and laser in situ keratomileusis (LASIK) for myopia. Methods. An adaptive optics visual simulator (CRX1, Imagine Eyes, France) was used to simulate the vision after ICL implantation and LASIK procedure from the wavefront aberration pattern for -3 and -6 D. Monocular visual acuity (VA) at different contrasts and contrast sensitivity (CS) at 10, 20, and 25 cycles/degree (cpd) were measured for 3- and 5-mm pupils. Modulation transfer function (MTF) and point spread function (PSF) were calculated for a 5-mm pupil. Results. The ICL showed a MTF near of diffraction-limited MTF, but the post-LASIK of MTF worsened…
Trifocal toric intraocular lenses in eyes with low amount of corneal astigmatism.
2020
Aim To evaluate the refractive and visual outcomes following cataract surgery and implantation of a trifocal toric intraocular lens (IOL) in eyes with low degrees of corneal astigmatism. Methods Twenty-six eyes of 22 patients who underwent implantation a trifocal toric IOL (FineVision PODFT, PhysIOL s.a., Liege, Belgium) were enrolled. Phacoemulsification with femtosecond laser, capsular tension ring insertion and intraoperative aberrometry were performed in all cases. All IOLs used showed a cylinder power of 1.00 D. Main outcome measures were refractive error and corrected-distance visual acuity (CDVA) and uncorrected-distance visual acuity (UDVA) values. Eyes were evaluated at 4mo post-su…
Outcome of Bleb Revision With Autologous Conjunctival Graft Alone or Combined With Donor Scleral Graft for Late-onset Bleb Leakage With Hypotony Afte…
2020
Prcis Treatment of leakage with ocular hypotony after trabeculectomy with mitomycin C (MMC) can be safely achieved through conjunctival patch alone or combined with donor scleral graft in cases of melted underlying sclera. Purpose To report outcomes of 2 surgical approaches for treating ocular hypotony in eyes with blebs with late-onset leakage after standard trabeculectomy with MMC. Methods Thirty consecutive cases with bleb leakage and hypotony underwent bleb revision surgery between 2009 and 2014 by the same surgeon (J.W.) at the Department of Ophthalmology of the Mainz University Medical Center, Germany. In 18 patients, an autologous conjunctival patch graft was applied. In 12 patients,…