Search results for "Visual Fields"

showing 8 items of 78 documents

High myopic patients with and without foveoschisis: morphological and functional characteristics.

2020

Purpose: Myopic foveoschisis (MF) is characterized by the splitting of the retinal layers in the fovea of patients with high myopia (HM). MF may progress into foveal detachment or macular hole formation with consequent loss of central vision. The aim of this study is to investigate morphological and functional changes of the macular region in myopic subjects with and without foveoschisis. Design: Observational, cross-sectional, comparative study. Methods: Forty-eight patients with HM and 24 healthy controls were evaluated by spectral domain-optical coherence tomography (SD-OCT), multifocal electroretinography (mfERG) and microperimetry (MP-1) tests to assess macular thickness, functionality…

Myopic foveoschisisMalemedicine.medical_specialtyFovea Centralisgenetic structuresRetinoschisisVisual AcuityRetinoschisisFoveoschisisRetina03 medical and health scienceschemistry.chemical_compound0302 clinical medicinePhysiology (medical)OphthalmologyHigh myopiaVitrectomyPost-hoc analysismedicineChi-square testElectroretinographyHumansMacular holePathological myopiabusiness.industryMultifocal electroretinography (mfERG)RetinalMiddle Agedmedicine.diseaseRetinal Perforationseye diseasesSensory SystemsSpectral domain-optical coherence tomography (SD-OCT)high myopia; microperimetry (MP-1); multifocal electroretinography (mfERG); myopic foveoschisis; pathological myopia; retinoschisis; spectral domain-optical coherence tomography (SD-OCT)OphthalmologyCross-Sectional StudieschemistryMyopia Degenerative030221 ophthalmology & optometryMicroperimetry (MP-1)Visual Field TestsFemalesense organsAnalysis of varianceVisual FieldsbusinessMicroperimetry030217 neurology & neurosurgeryTomography Optical CoherenceDocumenta ophthalmologica. Advances in ophthalmology
researchProduct

In vitro optical quality differences between multifocal apodized diffractive intraocular lenses.

2013

Purpose To compare the in vitro optical quality of multifocal apodized intraocular lenses (IOLs) at different focal points. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The Acrysof Restor +3.0 diopter (D) multifocal IOL with 2 main foci (bifocal IOL) and the Finevision multifocal IOL with 3 main foci (trifocal IOL) were evaluated. The optical quality was quantified using the modulation transfer function (MTF) at 7 focal points and for 3.0 mm and 4.5 mm apertures. The through-focus MTF at 10 focal points of the IOLs was also recorded. Results For the 0.0 D and −2.5 D focal points, the bifocal IOL showed the highest MTF values for pupil sizes as well as …

PhysicsLenses IntraocularFocal pointOptics and Photonicsbusiness.industryApertureProsthesis DesignSensory SystemsOptical qualityOphthalmologyOpticsCardinal pointApodizationIntraocular lensesOptical transfer functionSurgeryVisual FieldsbusinessDioptreVision OcularJournal of cataract and refractive surgery
researchProduct

The effect of fractal contact lenses on peripheral refraction in myopic model eyes.

2014

Purpose: To test multizone contact lenses in model eyes: Fractal Contact Lenses (FCLs), designed to induce myopic peripheral refractive error (PRE). Methods: Zemax ray-tracing software was employed to simulate myopic and accommodation-dependent model eyes fitted with FCLs. PRE, defined in terms of mean sphere M and 90–180 astigmatism J180, was computed at different peripheral positions, ranging from 0 to 35 in steps of 5, and for different pupil diameters (PDs). Simulated visual performance and changes in the PRE were also analyzed for contact lens decentration and model eye accommodation. For comparison purposes, the same simulations were performed with another commercially available conta…

Refractive errorMaterials scienceAstigmatismProsthesis DesignRefraction OcularModels BiologicalPupilMyopia progressionCellular and Molecular NeuroscienceFractalOpticsmedicineMyopiaHumansContact lensesZemaxbusiness.industryModel eyesPeripheral refractionAccommodation Ocularmedicine.diseaseContact Lenses HydrophilicRefractionSensory SystemsContact lensOphthalmologyFractalsFISICA APLICADAVisual FieldsbusinessAccommodationCurrent eye research
researchProduct

Seeing with the visual cortex

1984

A short analysis of the input-output organization of the primary visual cortical areas in the cat and monkey is followed by a description of the salient microelectrophysiological properties of retino-geniculo-cortical system neurons. It is concluded that a strict hierarchical model of cortical processing of visual information is no longer tenable.

Retinal Ganglion Cellsgenetic structuresMotion PerceptionDermatologyVisual systemCortical processingmedicineAnimalsVisual PathwaysBinocular neuronsVisual CortexBrain MappingOrientation columnGeneral NeuroscienceGeniculate BodiesHaplorhiniGeneral MedicineForm PerceptionPsychiatry and Mental healthVisual cortexmedicine.anatomical_structureSalientSynapsesCatsVisual PerceptionNeurology (clinical)Visual FieldsPsychologyNeuroscienceThe Italian Journal of Neurological Sciences
researchProduct

Ether-lipid and docosahexaenoic acid (DHA) levels in erythrocytes of patients with glaucoma

2008

International audience; Purpose: : Neuronal tissues such as the brain and the retina are known to contain elevated amounts of phospholipids with a vinyl-ether double bond (ether-lipids or plasmalogens) as well as high concentrations of long-chain omega-3 polyunsaturated fatty acids (docosahexaenoic acid or DHA). Abnormal blood levels of ether-lipids and DHA have been associated with several neurological disorders such as Alzheimer Disease. Since many observations bring up the idea of pathogenetic similarities between Alzheimer Disease and glaucoma, the aim of our work was to check whether ether-lipid and DHA levels were modified in glaucoma patients. Methods: : Blood samples were collected …

[SDV] Life Sciences [q-bio]lipidsgenetic structures[SPI.GPROC] Engineering Sciences [physics]/Chemical and Process Engineering[SDV]Life Sciences [q-bio][SDV.IDA]Life Sciences [q-bio]/Food engineeringvisual fieldslipids (amino acids peptides and proteins)[SPI.GPROC]Engineering Sciences [physics]/Chemical and Process Engineering[SDV.IDA] Life Sciences [q-bio]/Food engineeringclinical laboratory testing
researchProduct

Current Clinical Application of Microperimetry: A Review.

2018

Microperimetry (MP) is a technology that allows the study of retinal sensitivity at different foveal and parafoveal areas as well as eye fixation. It is a technique of functional evaluation, providing a direct correlation between anatomical and functional outcomes. There are a great variety of studies which evaluate the repeatability or reliability of measurements obtained with this technology and also describe and explore different clinical applications. MP has been shown to be useful in the characterization of sensory and motor conditions, such as amblyopia or nystagmus. Concerning ocular pathology, several studies have confirmed the usefulness of MP for evaluating and analyzing different…

medicine.medical_specialtygenetic structuresOcular PathologyGlaucomaNystagmusFixation OcularAmblyopiaMicroperimetryOcular Motility Disorders03 medical and health scienceschemistry.chemical_compoundNystagmus0302 clinical medicineOcular Motility DisordersRetinal DiseasesFovealOphthalmologymedicineHumansRetinal sensitivityVisual rehabilitationÓpticabusiness.industryReproducibility of ResultsRetinalGeneral MedicineMacular degenerationmedicine.diseaseeye diseasesOphthalmologychemistryEye fixation030221 ophthalmology & optometryVisual Field Testsmedicine.symptomVisual FieldsbusinessMicroperimetry030217 neurology & neurosurgerySeminars in ophthalmology
researchProduct

Mapping of the human visual cortex using image-guided transcranial magnetic stimulation

2002

We describe a protocol using transcranial magnetic stimulation (TMS) to systematically map the visual sensations induced by focal and non-invasive stimulation of the human occipital cortex. TMS is applied with a figure of eight coil to 28 positions arranged in a 2x2-cm grid over the occipital area. A digitizing tablet connected to a PC computer running customized software, and audio and video recording are used for detailed and accurate data collection and analysis of evoked phosphenes. A frameless image-guided neuronavigational device is used to describe the position of the actual sites of the stimulation coils relative to the cortical surface. Our results show that TMS is able to elicit p…

medicine.medical_specialtygenetic structuresmedicine.medical_treatmentPhosphenesSensory systemAudiologyBlindnessCortex (anatomy)medicineHumansVisual CortexBrain MappingPatient SelectionGeneral NeuroscienceTranscranial Magnetic StimulationTranscranial magnetic stimulationVisual cortexmedicine.anatomical_structurePhospheneVisual prosthesisHuman visual system modelTranscutaneous Electric Nerve StimulationVisual PerceptionEvoked Potentials VisualVisual FieldsPsychologyNeuroscienceGraphics tabletBrain Research Protocols
researchProduct

Motion perception in early glaucoma

2013

Purpose: The aim of our study was to underline the changes in the movement perception for early glaucoma. Our working hypothesis consisted in inquiring if the impairment of the magnocellular pathway may modify the movement perception capabilities in the visual field, more particularly in its peripheral area.Methods: We included 14 healthy subjects and 14 patients with early primary open angle glaucoma. A moving target was presented on a semicircular screen (1.8 m diameter); participants were asked to localize the Ending Point (EP) of each movement. Each stimulus consisted in a white dot (0,72° of diameter) moving horizontally with the imposed velocity profile. Two different laws of motion w…

visual fieldmedicine.medical_specialty641 perceptiongenetic structuresOpen angle glaucoma758 visual fieldsGlaucomaperceptionStimulus (physiology)Standard deviationchamp visuel03 medical and health sciences0302 clinical medicineOptics[ SDV.MHEP ] Life Sciences [q-bio]/Human health and pathologyOphthalmologymedicineMotion perception[SDV.MHEP.OS]Life Sciences [q-bio]/Human health and pathology/Sensory Organs030304 developmental biologyganglion0303 health sciences[SDV.MHEP] Life Sciences [q-bio]/Human health and pathology531 ganglion cellsbusiness.industryGeneral MedicineEarly glaucomacellmedicine.diseasePeripheralVisual fieldOphthalmology[SDV.MHEP.OS] Life Sciences [q-bio]/Human health and pathology/Sensory Organs[ SDV.MHEP.OS ] Life Sciences [q-bio]/Human health and pathology/Sensory Organs030221 ophthalmology & optometrycellulebusiness[SDV.MHEP]Life Sciences [q-bio]/Human health and pathologyActa Ophthalmologica
researchProduct