Search results for "Volunteer"

showing 10 items of 304 documents

Performing allocentric visuospatial judgments with induced distortion of the egocentric reference frame: an fMRI study with clinical implications

2003

The temporary improvement of visuospatial neglect during galvanic vestibular stimulation (Scand. J. Rehabil. Med. 31 (1999)117) may result from correction of the spatial reference frame distorted by the responsible lesion. Prior to an investigation of the neural basis of this effect in neurological patients, exploration of the neural mechanisms underlying such procedures in normals is required to provide insight into the physiological basis thereof. Despite their clinical impact, the neural mechanisms underlying the interaction of galvanic (and other) vestibular manipulations with visuospatial processing (and indeed the neural bases of how spatial reference frames are computed in man) remai…

AdultMaleEye MovementsCognitive Neurosciencemedia_common.quotation_subjectVisuospatial neglectNeglectPerceptual DisordersPremotor cortexCerebellumImage Processing Computer-AssistedmedicineHumansGalvanic vestibular stimulationmedia_commonCerebral CortexVestibular systemMagnetic Resonance ImagingElectric StimulationOxygenNormal volunteersmedicine.anatomical_structureNeurologySpace PerceptionVisual PerceptionRight posteriorFemaleVestibule LabyrinthPsychologyNeurosciencePhotic StimulationPsychomotor PerformanceReference frameCognitive psychologyNeuroImage
researchProduct

Reliability in perimetric multichannel contrast sensitivity measurements

2014

Background: In this study, the reliability of perimetric contrast sensitivity measurements favouring the achromatic, the red-green and the blue-yellow post-receptorial mechanisms was analysed. Methods: A new technique, multichannel ATD perimetry, provides spatial and temporal stimuli favouring the detection by an achromatic mechanism (A), from a magno or parvocellular origin or by a red-green (RG) chromatic mechanism, with a parvocellular origin or a blue-yellow (BY) mechanism, with a koniocellular origin. The repeatability and reproducibility of contrast sensitivity measurements with these stimuli were studied in a group of 40 healthy subjects. The analysis was carried out on 21 testing po…

AdultMaleFovea Centralismedia_common.quotation_subjectMultichannel perimetryAgreementlaw.inventionContrast SensitivityYoung AdultOpticsParvocellular celllawHumansContrast (vision)RepeatabilityContrast sensitivityReliability (statistics)Ópticamedia_commonMathematicsReproducibilitybusiness.industryReproducibility of ResultsRepeatabilityHealthy VolunteersReproducibilityVisual fieldOphthalmologyKoniocellular cellROC CurveAchromatic lensVisual Field TestsFemaleVisual FieldsbusinessOptometryBiomedical engineeringClinical and Experimental Optometry
researchProduct

Structural hemispheric asymmetries underlie verbal Stroop performance

2017

Performance on tasks involving cognitive control such as the Stroop task is often associated with left lateralized brain activations. Based on this neuro-functional evidence, we tested whether leftward structural grey matter asymmetries would also predict inter-individual differences in combatting Stroop interference. To check for the specificity of the results, both a verbal Stroop task and a spatial one were administered to a total of 111 healthy young individuals, for whom T1-weighted magnetic resonance imaging (MRI) images were also acquired. Surface thickness and area estimations were calculated using FreeSurfer. Participants' hemispheres were registered to a symmetric template and Lat…

AdultMaleFreeSurferSurface areaPrefrontal CortexContext (language use)Grey matterbehavioral disciplines and activities050105 experimental psychologyTask (project management)Verbal StroopCorrelationYoung Adult03 medical and health sciencesBehavioral NeuroscienceFreeSurfer; Hemispheric asymmetry; Spatial Stroop; Surface area; Verbal Stroop; Visual word form area; Behavioral NeuroscienceCognition0302 clinical medicineImage Processing Computer-AssistedmedicineHumans0501 psychology and cognitive sciencesVisual word form areaGray MatterDominance CerebralCerebral CortexBrain MappingSettore M-PSI/02 - Psicobiologia E Psicologia Fisiologica05 social sciencesSpatial StroopBrainCognitionHealthy VolunteerMagnetic Resonance ImagingHealthy Volunteersmedicine.anatomical_structureVisual word form areaStroop TestLateralityHemispheric asymmetryFemalePsychology030217 neurology & neurosurgeryHumanStroop effectCognitive psychologyBehavioural Brain Research
researchProduct

Redundant and synergistic information transfer in cardiovascular and cardiorespiratory variability

2015

In the framework of information dynamics, new tools are emerging which allow one to quantify how the information provided by two source processes about a target process results from the contribution of each source and from the interaction between the sources. We present the first implementation of these tools in the assessment of short-term cardiovascular and cardiorespiratory variability, by introducing two strategies for the decomposition of the information transferred to heart period (HP) variability from systolic arterial pressure (SAP) and respiration flow (RF) variability. Several measures based on the notion of transfer entropy (TE) are defined to quantify joint, individual and redun…

AdultMaleInformation transferComputer scienceEntropyBiomedical EngineeringBlood PressureHealth Informaticscomputer.software_genreCardiovascular Physiological PhenomenaElectrocardiographyHeart RateHumansPaced breathingSimulation1707Motor NeuronsRespirationModels CardiovascularHealthy subjectsHeartCardiorespiratory fitnessHealthy VolunteersSignal ProcessingSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaSystolic arterial pressureFemaleTransfer entropyData miningcomputer
researchProduct

The effects of prostaglandin F2α in the human eye

1985

The ocular effects of 200 micrograms of topically applied prostaglandin F2 alpha were studied in 18 nonglaucomatous volunteers. A fall in intraocular pressure was seen in the prostaglandin-treated eyes when compared with the placebo-treated control eyes. The maximum intraocular pressure reduction was observed at the 7th h and hypotensive ocular effect persisted for 24 h. Prostaglandins did not produce any change in pupillary diameter or signs of intraocular inflammation visible by anterior segment biomicroscopy or iris fluorescein angiography. The drug caused side effects: conjunctival hyperemia was constant and many patients complained of ocular smarting and headache. It could be useful in…

AdultMaleIntraocular pressuregenetic structuresOcular hypertensionProstaglandinHyperemiaDinoprostEyePupilCellular and Molecular Neurosciencechemistry.chemical_compoundHumansMedicineIris (anatomy)VolunteerIntraocular PressureAgedmedicine.diagnostic_testbusiness.industryProstaglandins FHeadacheMiddle Agedmedicine.diseaseFluorescein angiographyeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structurechemistryAnesthesiaFemaleHuman eyesense organsbusinessConjunctivaGraefe's Archive for Clinical and Experimental Ophthalmology
researchProduct

Transpalpebral tonometry: reliability and comparison with Goldmann applanation tonometry and palpation in healthy volunteers

2005

Background/aim: TGDc-01 is a new, portable, transpalpebral tonometry device. The aim of this study was to evaluate the reproducibility of this method, including intraobserver and interobserver deviations, and to compare the results with those of Goldmann applanation tonometry and palpation of intraocular pressure (IOP). Methods: A total of 40 eyes of 20 healthy volunteers were included. Two independent parallel observers (1 and 2) performed three replicate measurements per eye, respectively, both using TGDc01 tonometry, one observer (3) performed three replicate measurements using Goldmann applanation tonometry, and one observer (4) measured the IOP via palpation. Intraindividual deviations…

AdultMaleIntraocular pressuremedicine.medical_specialtyClinical Science - Scientific ReportsPalpationGoldmann applanation tonometryTonometry OcularCellular and Molecular NeuroscienceInterquartile rangeOphthalmologyHealthy volunteersHumansMedicineIn patientIntraocular PressureObserver VariationReproducibilityPalpationmedicine.diagnostic_testbusiness.industryReproducibility of ResultsEquipment DesignSensory SystemsOphthalmologyQuartileFemalebusinessBritish Journal of Ophthalmology
researchProduct

Tidal Volume Estimation during Helmet Noninvasive Ventilation: an Experimental Feasibility Study

2019

AbstractWe performed a bench (BS) and human (HS) study to test the hypothesis that estimation of tidal volume (VT) during noninvasive helmet pressure support ventilation (nHPSV) would be possible using a turbine driven ventilator (TDV) coupled with an intentional leak single-limb vented circuit. During the BS a mannequin was connected to a lung simulator (LS) and at different conditions of respiratory mechanics, positive end expiratory pressure (PEEP) levels and leaks (30, 50 and 80 L/min). All differences were within the 95% limits of agreement (LoA) in all conditions in the Bland-Altman plot. The overall bias (difference between VT measured by TDV and LS) was 35 ml (95% LoA 10 to 57 ml), …

AdultMaleLeakmedicine.medical_specialtylcsh:MedicineSettore MED/41 - AnestesiologiaPressure support ventilationTherapeuticsRespiratory physiologyManikinsArticlePositive-Pressure Respiration03 medical and health sciences0302 clinical medicineInternal medicineHealthy volunteersTidal VolumemedicineHumanslcsh:SciencePositive end-expiratory pressureTidal volumeMouthpieceVentilators Mechanicalacute respiratory failureMultidisciplinarybusiness.industrylcsh:RhelmetReproducibility of Resultsnoninvasive ventilation030208 emergency & critical care medicineEquipment DesignHealthy Volunteers030228 respiratory systemPreclinical researchRespiratory MechanicsCardiologyFeasibility Studieslcsh:QFemaleHead Protective DevicesNoninvasive ventilationbusinessScientific Reports
researchProduct

Light distortion of soft multifocal contact lenses with different pupil size and shape

2020

Purpose: To study the light distortion effects of soft multifocal contact lenses and the influence of different pupil size and shape.Methods: A total of 14 eyes of 7 healthy contact lens users (mean age 28.6 +/- 8.5 years) were recruited. The "Light Disturbance Analyser" device was employed for light characterization. The selected lenses were the monthly disposable "Biofinity multifocal" (CooperVision, CA, USA), both centre-distance and centre-near designs (addition power + 2.50 D). Two circular pupils of 3 mm and 5 mm of diameter, and an elliptical shape (3 horizontal and 5 vertical mm) were used. Metrics such as the light distortion index (LDI), best-fit circle radius and its irregularity…

AdultMaleLight distortionbusiness.product_categorygenetic structuresCiências Naturais::Ciências Físicas:Ciências Físicas [Ciências Naturais]Visual AcuityRefraction OcularPupillaw.invention03 medical and health sciences0302 clinical medicineOpticslawDistortionNon-circular pupilsHumansMultifocal lensesMathematicsScience & Technologybusiness.industryPupil sizePupilMean ageEquipment DesignGeneral MedicineRadiusMiddle AgedContact Lenses HydrophilicRefractive ErrorsHealthy Volunteerseye diseasesContact lensLens (optics)Ophthalmology030221 ophthalmology & optometryMultifocal contact lensesFemalesense organsbusiness030217 neurology & neurosurgeryOptometryContact Lens and Anterior Eye
researchProduct

Beyond the amygdala: Linguistic threat modulates peri-sylvian semantic access cortices

2015

In this study, healthy volunteers were scanned using functional magnetic resonance imaging (fMRI) to investigate the neural systems involved in processing the threatening content conveyed via visually presented “threat words.” The neural responses elicited by these words were compared to those elicited by matched neutral control words. The results demonstrate that linguistic threat, when presented in written form, can selectively engage areas of lateral temporal and inferior frontal cortex, distinct from the core language areas implicated in aphasia. Additionally, linguistic threat modulates neural activity in visceral/emotional systems (amygdala, parahippocampal gyrus and periaqueductal gr…

AdultMaleLinguistics and LanguageVisual perceptionAdolescentCognitive NeuroscienceNeocortexExperimental and Cognitive PsychologyAmygdalaBrain mappingArticleLanguage and LinguisticsYoung AdultSpeech and HearingFunctional neuroimagingAphasiaAphasiamedicineHumansPeriaqueductal GrayBrain MappingLanguage Testsmedicine.diagnostic_testFearAmygdalaMagnetic Resonance ImagingHealthy VolunteersLinguisticsFrontal LobeSemanticsmedicine.anatomical_structureFrontal lobeVisual PerceptionParahippocampal GyrusFemalemedicine.symptomPsychologyFunctional magnetic resonance imagingParahippocampal gyrusCognitive psychologyBrain and Language
researchProduct

An Emerging Method to Assess Tear Film Spread and Dynamics as Possible Tear Film Homeostasis Markers

2021

This study aims to assess the performance of an analysis method to measure in vivo the movement speed of tear film particles post-blink as a measure of tear film spreading. Ocular surface parameter...

AdultMaleMaterials scienceAdolescentgenetic structuresMeasure (physics)Young Adult03 medical and health sciencesCellular and Molecular Neuroscience0302 clinical medicineHomeostasisHumansAnalysis methodAgedAged 80 and overBlinkingDynamics (mechanics)Meibomian GlandsMiddle AgedHealthy Volunteerseye diseasesSensory SystemsOphthalmologyTears030221 ophthalmology & optometryDry Eye SyndromesFemalesense organsOcular surface030217 neurology & neurosurgeryBiomedical engineeringCurrent Eye Research
researchProduct