Search results for "WAVELENGTH"
showing 10 items of 741 documents
High-power pulsed dye laser with Fourier-limited bandwidth
1986
A high-peak-power, narrow-linewidth light source with a homogeneous beam profile has been constructed by modifications to a commercially available pulsed-dye-laser system. Output pulses of up to 10 mJ were generated with linewidths of about 50 MHz for 12-nsec pulses. The pulse-to-pulse frequency stability was better than the linewidth, and the center frequency could be scanned over a frequency range of 142.5 GHz at a wavelength of 600 nm. The performance of the system was demonstrated by observing the 6s2 1S0–6s7s1S0 transition in atomic mercury at 2λ = 312.8 nm and the 6s2S1/2–8s2S1/2 transition in atomic gold at 2λ = 308.9 nm using up to 1 mJ of frequency-doubled output for two-photon non…
A novel multi-wavelength procedure for blood pressure estimation using opto-physiological sensor at peripheral arteries and capillaries
2018
© 2018 SPIE. In this study, the Carelight multi-wavelength opto-electronic patch sensor (OEPS) was adopted to assess the effectiveness of a new approach for estimating the systolic blood pressure (SBP) through the changes in the morphology of the OEPS signal. Specifically, the SBP was estimated by changing the pressure exerted on an inflatable cuff placed around the left upper arm. Pressure acquisitions were performed both with gold standard (i.e. electronic sphygmomanometer), and Carelight sensor (experimental procedure), on subjects from a multiethnic cohort (aged 28 ± 7). The OEPS sensor was applied together with a manual inflatable cuff, going slightly above the level of the SBP with in…
Photonic processing of microwave signals
2005
In this paper, recent advances in the implementation of photonic tuneable transversal filters for RF signal processing developed by the Optical Communications Group are described. After a brief introduction to the field and the basic concepts, limiting factors and application of these filters are described in the field. This is based on a distinction between filters based on wavelength tuneable optical taps and others based on the tuneability of the dispersive elements that provide the time delay between samples. Recently developed approaches have also been discussed.
Three-Dimensional Printing of Nonlinear Optical Lenses.
2018
In the current paper, a series of nonlinear optical (NLO) active devices was prepared by utilizing stereolithographic three-dimensional printing technique. Microcrystalline NLO active component, urea, or potassium dihydrogen phosphate was dispersed in a simple photopolymerizable polyacrylate-based resin and used as the printing material to fabricate highly efficient transparent NLO lenses. The nonlinear activity of the printed lenses was confirmed by second-harmonic generation measurements using a femtosecond laser-pumped optical parametric amplifier operating at a wavelength of 1195 nm. The three-dimensional printing provides a simple method to utilize a range of NLO active compounds witho…
Simultaneous recording of skin blood pulsations at different vascular depths by multiwavelength photoplethysmography.
2007
A new technique for parallel recording of reflection photoplethysmography (PPG) signals in a broad spectral band (violet to near-infrared) has been developed, and its potential for assessment of blood microcirculation at various depths from the skin surface is discussed. PPG signals have been simultaneously detected at cw laser wavelength sets comprising 405, 532, 645, 807, and 1064 nm. Various signal baseline responses to breath holding and different shapes of the PPG pulses originated from the same heartbeat but recorded at different wavelengths have been observed, indicating a depth variety of the skin blood pulsation dynamics.
Contact probe pressure effects in skin multi-spectral photoplethysmography
2007
A novel technique ensuring parallel recording of reflection photoplethysmography signals in broad spectral range has been tested for assessment of pressure-induced vascular changes at various depths from the skin surface. PPG signals have been simultaneously detected at three combinations of the cw laser wavelengths 405 nm, 532 nm, 645 nm, 807 nm and 1064 nm. The PPG baseline responses to the probe-skin contact pressure changes and shapes of the PPG pulses originated from the same heartbeat but recorded at different wavelengths have been detected and analyzed.
Multi-wavelength photoplethysmography for simultaneous recording of skin blood pulsations at different vascular depths
2007
Parallel recording of reflection photoplethysmography (PPG) signals in broad spectral band has been performed, and potential of this approach for assessment of blood microcirculation at various vascular depths is discussed. PPG signals have been simultaneously detected at cw laser wavelengths sets comprising 405 nm, 532 nm, 645 nm, 807 nm and 1064 nm. Different signal baseline responses to breath holding at different wavelengths have been observed, as well as different shapes of the PPG pulses originated from the same heartbeat.
Time-dependent effects in the nonsequential ionization of helium at various wavelengths
2000
Calculations of the double ionization of a model 1D helium atom interacting with an intense short laser pulse are presented. A substantial signature of nonsequential double ionization is found for all the wavelengths that are considered, from 248 nm to 1064 nm, provided that sufficiently short pulses are employed. We show how one can modify the size of the “knee” structure of the double ionization yield curve by varying the laser pulse duration. The underlying mechanism of the correlated double electron ejection is investigated and discussed.
Upconversion Nanoparticles for Bioimaging and Regenerative Medicine.
2016
Nanomaterials are proving useful for regenerative medicine in combination with stem cell therapy. Nanoparticles can be administrated and targeted to desired tissues or organs and subsequently, be used in non-invasive real-time visualization and tracking of cells by means of different imaging techniques, they can act as therapeutic agent nanocarriers, and can also serve as scaffolds to guide the growth of new tissue. Nanoparticles can be of different chemical nature, such as gold, iron oxide, cadmium selenide, and carbon, and have the potential to be used in regenerative medicine. However, there are still many issues to be solved, such as toxicity, stability, and resident time. Upconversion …
Highly sensitive optical hydrogen sensor using circular Pd-coated singlemode tapered fibre
2001
A novel optical hydrogen sensor, based on the absorption change of the evanescent fields in a circular Pd-coated singlemode tapered fibre is presented. The proposed sensor is polarisation independent and its sensitivity is adjustable by means of the taper diameter, interaction length, and/or light wavelength. A simple light transmission measurement setup is used to test the sensor. The sensor is suitable for the detection of low hydrogen concentrations with high sensitivity and fast time response. Transmission changes as high as 60% are demonstrated.