Search results for "WEARABLE"
showing 10 items of 133 documents
Gait Variability Using Waist- and Ankle-Worn Inertial Measurement Units in Healthy Older Adults
2020
Gait variability observed in step duration is predictive of impending adverse health outcomes among apparently healthy older adults and could potentially be evaluated using wearable sensors (inertial measurement units, IMU). The purpose of the present study was to establish the reliability and concurrent validity of gait variability and complexity evaluated with a waist and an ankle-worn IMU. Seventeen women (age 74.8 (SD 44) years) and 10 men (73.7 (4.1) years) attended two laboratory measurement sessions a week apart. Their stride duration variability was concurrently evaluated based on a continuous 3 min walk using a force plate and a waist- and an ankle-worn IMU. Their gait complexity (…
Combining Ergonomic Risk Assessment (RULA) with Inertial Motion Capture Technology in Dentistry—Using the Benefits from Two Worlds
2021
Traditional ergonomic risk assessment tools such as the Rapid Upper Limb Assessment (RULA) are often not sensitive enough to evaluate well-optimized work routines. An implementation of kinematic data captured by inertial sensors is applied to compare two work routines in dentistry. The surgical dental treatment was performed in two different conditions, which were recorded by means of inertial sensors (Xsens MVN Link). For this purpose, 15 (12 males/3 females) oral and maxillofacial surgeons took part in the study. Data were post processed with costume written MATLAB® routines, including a full implementation of RULA (slightly adjusted to dentistry). For an in-depth comparison, five newly i…
Reliability and concurrent validity of spatiotemporal stride characteristics measured with an ankle-worn sensor among older individuals
2019
Background. Wearable inertial sensors have been shown to provide valid mean gait characteristics assessments, however, assessment of variability is less convincingly established. Research question. What level of concurrent validity, and session-to-session reliability does an ankle-worn inertial measurement unit (IMU)-based gait assessment with a novel angular velocity-based gait event detection algorithm have among older adults? Methods. Twenty seven (women N = 17) participants volunteered (age 74.4 (SD 4.3) years, body mass 74.5 (12.0) kg, height 165.9 (9.9) cm). Right leg stance, swing, and stride duration and stride length, and stride velocity were concurrently assessed with motion captu…
Laboratory-Based Gait Variability and Habitual Gait Entropy Do Not Differentiate Community-Dwelling Older Adults from Those with Subjective Memory Co…
2019
Background: Age-related cognitive decline may be delayed with appropriate interventions if those at high risk can be identified prior to clinical symptoms arising. Gait variability assessment has emerged as a promising candidate prognostic indicator, however, it remains unclear how sensitive gait variability is to early changes in cognitive abilities. Research question: Do community-dwelling adults over 65 years of age with subjective memory complaints differ from those with no subjective memory concerns in terms of laboratory-measured or free-living gait variability? Methods: This cross-sectional study recruited 24 (age = 73.5(SD 6.4) years) community-dwelling people with subjective memory…
Validation of a novel contact-free heart and respiratory rate monitor.
2021
There is a growing need for remote monitoring of patients due to a lack of resources and infection control. Current systems use sensors that require constant physical contact with the user, which may result in discomfort or lack of adherence. In the present study, we evaluated the accuracy of a new contact-free system to monitor heart and respiratory rate. Study participants were measured simultaneously using two devices: a contact-free optical system that measures nano-vibrations and movements (investigational device, "Gili Pro BioSensor") and a standard reference bed-side monitor, inclusive of an electrocardiogram and capnograph modules (Mindray
Profiles of Volatile Biomarkers Detect Tuberculosis from Skin
2021
Abstract Tuberculosis (TB) is an infectious disease that threatens >10 million people annually. Despite advances in TB diagnostics, patients continue to receive an insufficient diagnosis as TB symptoms are not specific. Many existing biodiagnostic tests are slow, have low clinical performance, and can be unsuitable for resource‐limited settings. According to the World Health Organization (WHO), a rapid, sputum‐free, and cost‐effective triage test for real‐time detection of TB is urgently needed. This article reports on a new diagnostic pathway enabling a noninvasive, fast, and highly accurate way of detecting TB. The approach relies on TB‐specific volatile organic compounds (VOCs) that are …
Training-induced changes in daily energy expenditure: Methodological evaluation using wrist-worn accelerometer, heart rate monitor, and doubly labele…
2019
IntroductionWrist-mounted motion sensors can quantify the volume and intensity of physical activities, but little is known about their long-term validity. Our aim was to validate a wrist motion sensor in estimating daily energy expenditure, including any change induced by long-term participation in endurance and strength training. Supplemental heart rate monitoring during weekly exercise was also investigated.MethodsA 13-day doubly labeled water (DLW) measurement of total energy expenditure (TEE) was performed twice in healthy male subjects: during two last weeks of a 12-week Control period (n = 15) and during two last weeks of a 12-week combined strength and aerobic Training period (n = 13…
Key Influencing Factors in Early-Stage Hardware Startups: A Trilateral Model of Speed, Resource, and Quality
2020
Hardware startups, i.e., wearable devices, robotics, and Internet of Things, are a significant sector of technology startups, in which software development is relevant and needed. Compared to pure software startups, hardware development in startup contexts lacks a systematic approach and guidelines. This chapter describes an empirical model that captures common elements in product development approaches among many hardware startups. Grounded from insights of 18 active hardware startups, we constructed a trilateral model of resource, speed, and quality in early-stage product development. For startups with relevant contexts, the work suggests the preparation of internal, external resources, a…
A novel multi-wavelength procedure for blood pressure estimation using opto-physiological sensor at peripheral arteries and capillaries
2018
© 2018 SPIE. In this study, the Carelight multi-wavelength opto-electronic patch sensor (OEPS) was adopted to assess the effectiveness of a new approach for estimating the systolic blood pressure (SBP) through the changes in the morphology of the OEPS signal. Specifically, the SBP was estimated by changing the pressure exerted on an inflatable cuff placed around the left upper arm. Pressure acquisitions were performed both with gold standard (i.e. electronic sphygmomanometer), and Carelight sensor (experimental procedure), on subjects from a multiethnic cohort (aged 28 ± 7). The OEPS sensor was applied together with a manual inflatable cuff, going slightly above the level of the SBP with in…