A multi-objective and multi-criteria approach for district metered area design: water operation and quality analysis
2019
Water distribution network (WDN) operation may be improved by district metered area (DMA) design [1]. A first step to create DMAs uses graph theory and non-supervised learning, where physical features of the WDN, such as node coordinates, elevation and demand, are used for clustering purposes [2]. A second step is related to the necessary isolation of the clustered elements. For isolation purposes, it is important to determine the DMA entrances and, consequently, the needed cut-off valves. Closure of pipes and definition of DMA entrances can be set as an optimization problem with the costs associated to the valves, which are linked to pipe diameters, as a primary objective. However, placeme…
Water distribution network robust design based on energy surplus index maximization
2015
The aim of this paper is to show that energy surplus indices, such as resilience index, besides providing a very good indirect measure of water distribution network reliability to be adopted during the design phase, represent also a valuable and effective indicator of the robustness of the network in alternative network scenarios, and can thus be profitably used in condition of future demands uncertainty. The methodology adopted consisted of (I) multi-objective design optimization performed in order to minimize construction costs while maximizing the resilience index; (II) retrospective performance assessment of the alternative solutions of the Pareto front obtained, under demand conditions…
Assessing priority of intervention on water distribution networks with reduced information
2008
Real-time optimal control of water distribution systems - Models and techniques, including intermittent supply conditions.
2014
Optimal Network Design with the Use of Reliability Constraints and Simulated Annealing Tecnique
1996
Water quality analysis in network and private storage tanks in intermittent distribution systems
2012
In countries suffering from chronic water shortages, water distribution systems are often operated on an intermittent basis. As a consequence, the network is involved by cyclical filling and emptying periods causing water quality degradation. During the emptying period, the distribution system is unpressurised and it may occur that pollutants move into the network. Moreover, the stagnation period can promote microbial growth. For this reason water is usually heavily chlorinated in order to maintain it potable. Due to intermittent water service users acquire private tanks, which are used for collecting water during serviced periods and distributing it when public service is not available. Th…