Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…
2012
AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…
Effect of Simulated IOL Tilt and Decentration on Spherical Aberration After Hyperopic LASIK for Different Intraocular Lenses
2011
PURPOSE: To evaluate visual quality differences among intraocular lenses (IOLs) in patients with previous hyperopic laser ablations and to assess the impact of decentration and tilt of IOLs on visual quality. METHODS: An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of one aberration-correcting IOL (AcrySof IQ SN60WF, Alcon Laboratories Inc) and two spherical IOLs with different amounts of positive spherical aberration (Akreos Adapt [Bausch & Lomb] and Triplato [AJL Ophthalmic]) in five situations—centered, 0.2 mm and 0.4 mm of decentration, and 2° and 4° of tilt—in two groups: simulated low hyperopic laser corneal ablation (low hyperopia group)…
Visual simulation through an aspheric aberration-correcting intraocular lens in subjects with different corneal profiles using adaptive optics.
2013
The aim of this study was to analyse the visual quality of the AcrySof IQ SN60WF® intraocular lens (IOL) when combined with different corneal profiles. Ten eyes of 10 participants with no prior history of refractive or cataract surgery were evaluated. An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of an aspheric aberration-correcting IOL (AcrySof IQ SN60WF®). Normal corneas (group A), low and high myopic corneal ablations (groups B and C, respectively) and low and high hyperopic corneal ablations (groups D and E, respectively) were also simulated. Monocular distance visual acuities at 100, 50 and 10 per cent of contrast were measured. At 100, 50 an…
Lentes de contato corneoesclerais adaptadas em córneas irregulares após cirurgia LASIK
2018
ABSTRACT Purpose: We aimed to describe the outcomes of corneoscleral contact lens fitting with multi-aspherical geometry designs in patients with irregular corneas after laser-assisted in situ keratomileusis (LASIK). Methods: This was a retrospective series of 18 patients (age, 26-38 years) selected from an eye clinic database. Participants were required to have unsatisfactory visual acuity with their current contact lenses or spectacles after LASIK for myopia correction. All patients were fitted with corneoscleral contact lenses designed to correct corneal surface irregularities. A diagnostic trial set was used for fitting, and assessments were performed according to a standardized methodo…
Visual simulation through different intraocular lenses using adaptive optics: Effect of tilt and decentration
2011
Purpose To analyze visual quality differences between intraocular lenses (IOLs) and assess the impact of IOL decentration and tilt on visual quality. Setting University of Valencia, Valencia, Spain. Design Cohort study. Methods The crx1 adaptive optics visual simulator was used to simulate the wavefront aberration pattern of 2 commercially available aspheric aberration-correcting IOLs (Acrysof IQ SN60WF and Tecnis ZA9003) and 2 spherical IOLs (Akreos Adapt and Triplato) in 5 situations: centered, decentered 0.2 mm and 0.4 mm, and tilted 2 degrees and 4 degrees. Monocular distance visual acuity at 100%, 50%, and 10% contrast and the depth of focus were measured. Results Ten eyes of 10 patien…
Simulated prototype of posterior chamber phakic intraocular lens for presbyopia correction.
2014
Purpose To evaluate the visual impact of adding different spherical aberration values to an Implantable Collamer Lens phakic intraocular lens (pIOL) to increase the depth of focus using an adaptive optics visual simulator. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods Wavefront aberrations in −3.00 D and −6.00 diopter (D) pIOLs were measured in vitro. Afterward, different simulated pIOL experimental prototypes were created along with variances in the spherical aberration. An adaptive optics visual simulator was used to simulate vision after the implantation of the different pIOL prototypes from their wavefront aberrations. The corrected distance visual …
Depth of focus through different intraocular lenses in patients with different corneal profiles using adaptive optics visual simulation
2011
PURPOSE: To evaluate the depth of focus with monofocal intraocular lenses (IOLs) in patients with different corneal profiles using adaptive optics (AO) visual simulation. METHODS: An AO visual simulator (crx1, Imagine Eyes) was used to simulate the aberration pattern of three monofocal IOLs (Acrysof IQ SN60WF [Alcon Laboratories Inc]; Akreos Adapt AO [Bausch & Lomb]; and Triplato [AJL Ophthalmic]) of different optic designs. Five groups were considered: patients without any corneal refractive surgery (normal cornea group) and with prior low and high myopic and hyperopic ablations (low myopic ablation, high myopic ablation, low hyperopic ablation, and high hyperopic ablation groups). De…
Efficacy of Focused Extracorporeal Shock Wave Therapy in Chronic Low Back Pain: A Prospective Randomized 3-Month Follow-Up Study.
2022
BACKGROUND Extracorporeal shock wave therapy (ESWT) is a modern physiotherapeutic method that is useful for treating musculoskeletal conditions. There are still limited data from well-designed studies evaluating the clinical efficiency of ESWT in low back pain (LBP). Therefore, this study aimed to assess the effectiveness of the focused ESWT (fESWT) in reducing pain and improving the functional status of patients with chronic LBP. MATERIAL AND METHODS The study involved 40 patients with L5-S1 discopathy with chronic LBP pain who were randomized into 2 groups: group A (n=20, mean age of 42.3±13.1 years) and group B (n=20, mean age of 45.4±14 years). Group A was an experimental group treated …
The Effectiveness Of Radial Extracorporeal Shock Wave Therapy In Patients With Chronic Low Back Pain: A Prospective, Randomized, Single-Blinded Pilot…
2019
Karolina Walewicz,1 Jakub Taradaj,2,3 Katarzyna Rajfur,1 Kuba Ptaszkowski,4 MichaÅ Tomasz Kuszewski,2 MirosÅaw Sopel,5 Robert Dymarek5 1Faculty of Physiotherapy, Opole Medical School, Opole, Poland; 2Institute of Physiotherapy and Health Sciences, Academy of Physical Education, Katowice, Poland; 3College of Rehabilitation Sciences, University of Manitoba, Winnipeg, MB, Canada; 4Department of Physiotherapy, Wroclaw Medical University, Wroclaw, Poland; 5Department of Nervous System Diseases, Wroclaw Medical University, Wroclaw, PolandCorrespondence: Robert DymarekDepartment of Nervous System Diseases, Faculty of Health Sciences, Wroclaw Medical University, Bartla 5, Wroclaw 51-618, PolandTe…
Mobile phone base stations and adverse health effects: phase 1 of a population-based, cross-sectional study in Germany
2009
Objective: The aim of this first phase of a cross-sectional study from Germany was to investigate whether proximity of residence to mobile phone base stations as well as risk perception is associated with health complaints. Methods: The researchers conducted a population-based, multi-phase, cross-sectional study within the context of a large panel survey regularly carried out by a private research institute in Germany. In the initial phase, reported on in this paper, 30 047 persons from a total of 51 444 who took part in the nationwide survey also answered questions on how mobile phone base stations affected their health. A list of 38 health complaints was used. A multiple linear regression…