Search results for "Waveform"

showing 10 items of 131 documents

A Novel Computational Approach for Harmonic Mitigation in PV Systems with Single-Phase Five-Level CHBMI

2018

In this paper, a novel approach to low order harmonic mitigation in fundamental switching frequency modulation is proposed for high power photovoltaic (PV) applications, without trying to solve the cumbersome non-linear transcendental equations. The proposed method allows for mitigation of the first-five harmonics (third, fifth, seventh, ninth, and eleventh harmonics), to reduce the complexity of the required procedure and to allocate few computational resource in the Field Programmable Gate Array (FPGA) based control board. Therefore, the voltage waveform taken into account is different respect traditional voltage waveform. The same concept, known as “voltage cancelation”, used for single-…

PolynomialControl and OptimizationTranscendental equationComputer science020209 energyEnergy Engineering and Power Technologysoft switching02 engineering and technologySettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciComputational resourcelcsh:Technology7. Clean energyselective harmonic mitigationmultilevel power converter0202 electrical engineering electronic engineering information engineeringElectronic engineeringWaveformElectrical and Electronic EngineeringEngineering (miscellaneous)Photovoltaic systemlcsh:TRenewable Energy Sustainability and the EnvironmentPhotovoltaic systemPower (physics)phase shiftedSettore ING-IND/31 - ElettrotecnicaHarmonicsphotovoltaic systemsvoltage cancellationEnergy (miscellaneous)VoltageEnergies
researchProduct

Analysis of negative-resistance oscillators with piecewise nonlinearity

1977

An iterative method of solution of negative-resistance oscillators with piecewise-analytical characteristics is presented. The method allows the determination of the frequency and the harmonic content of the waveform as a function of the circuit parameters and bias of the nonlinear device. An application of the method, extended to the second order, for a polynomial characteristic limited by two straight lines is also reported. The results are compared with those obtained by numerical integration.

PolynomialIterative methodApplied MathematicsNegative resistanceMathematical analysisComputer Science ApplicationsElectronic Optical and Magnetic MaterialsNumerical integrationNonlinear systemControl theoryHarmonicPiecewiseWaveformElectrical and Electronic EngineeringMathematicsInternational Journal of Circuit Theory and Applications
researchProduct

Measuring Heart Rate with a Heat Flux Sensor

2021

Different wearable biosignal measurement applications require minimally obtrusive and highly sensitive sensors and methods of transducing the heart pulse into an electric signal. At the same time, the sensors should have minimal power consumption and preferably provide information about more than just the heart rate. In this study, a method employing a heat flux sensor for recording the pulsatile cardiac component of an arterial pulse waveform is presented. The output signals of a conventional photoplethysmography (PPG) sensor and a heat flux sensor were recorded and compared with one another. The results show that a heat flux sensor can be used for measurement of heart pulse, in addition t…

Pulse (signal processing)business.industryAcousticsPhotoplethysmogramHeat flux sensorHeart ratePulsatile flowWearable computerWaveformMedicineBiosignalbusiness2021 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)
researchProduct

Assessment of a Modified Acoustic Lens for Electromagnetic Shock Wave Lithotripters in a Swine Model

2013

The acoustic lens of the Modularis electromagnetic shock wave lithotripter (Siemens, Malvern, Pennsylvania) was modified to produce a pressure waveform and focal zone more closely resembling that of the original HM3 device (Dornier Medtech, Wessling, Germany). We assessed the newly designed acoustic lens in vivo in an animal model.Stone fragmentation and tissue injury produced by the original and modified lenses of the Modularis lithotripter were evaluated in a swine model under equivalent acoustic pulse energy (about 45 mJ) at 1 Hz pulse repetition frequency. Stone fragmentation was determined by the weight percent of stone fragments less than 2 mm. To assess tissue injury, shock wave trea…

Pulse repetition frequencyShock wavemedicine.medical_specialtySwineUrologySus scrofaMicroscopy AcousticSensitivity and SpecificityArticlelaw.inventionFocal zoneKidney CalculiElectromagnetic FieldsPressure waveformlawLithotripsymedicineAnimalsPulse energyEquipment Safetybusiness.industryEquipment DesignAcoustic lensSurgeryLens (optics)Disease Models AnimalShock wave lithotripterFemalebusinessBiomedical engineering
researchProduct

Time-Frequency Filtering for Seismic Waves Clustering

2014

This paper introduces a new technique for clustering seismic events based on processing, in time-frequency domain, the waveforms recorded by seismographs. The detection of clusters of waveforms is performed by a k-means like algorithm which analyzes, at each iteration, the time-frequency content of the signals in order to optimally remove the non discriminant components which should compromise the grouping of waveforms. This step is followed by the allocation and by the computation of the cluster centroids on the basis of the filtered signals. The effectiveness of the method is shown on a real dataset of seismic waveforms.

SeismometerInformation Systems and ManagementBasis (linear algebra)Computer sciencebusiness.industryComputationEarthquakes clusteringCentroidWaveforms clusteringComputer Science Applications1707 Computer Vision and Pattern RecognitionPattern recognitionInformation SystemSeismic noiseTime-frequency filteringwaveforms clustering earthquakes clustering time-frequency filteringSeismic wavePhysics::GeophysicsComputingMethodologies_PATTERNRECOGNITIONWaveformArtificial intelligenceSettore SECS-S/01 - StatisticaCluster analysisbusinessAnalysis
researchProduct

Palermo 2010 - Underwater seismic monitoring of the epicenter area of the 6 September 2002 Palermo Earthquake

2011

Settore GEO/11 - Geofisica ApplicataSettore GEO/10 - Geofisica Della Terra Solidamicroseismicity waveform clustering hypocenter localization
researchProduct

Dissimilarity Measures for the Identification of Earthquake Focal Mechanisms

2013

This work presents a study about dissimilarity measures for seismic signals, and their relation to clustering in the particular problem of the identification of earthquake focal mechanisms, i.e. the physical phenomena which have generated an earthquake. Starting from the assumption that waveform similarity implies similarity in the focal parameters, important details about them can be determined by studying waveforms related to the wave field produced by earthquakes and recorded by a seismic network. Focal mechanisms identification is currently investigated by clustering of seismic events, using mainly cross-correlation dissimilarity in conjunction with hierarchical clustering algorithm. By…

Settore INF/01 - InformaticaRelation (database)Cross-correlationComputer sciencebusiness.industryPattern recognitionField (computer science)Physics::GeophysicsHierarchical clusteringIdentification (information)Similarity (network science)WaveformArtificial intelligenceCluster analysisbusinessmetrics clustering seismic signals waveforms
researchProduct

GLM-based automatic picking of waveforms

2011

Settore SECS-S/01 - Statisticapicking glm approach waveforms
researchProduct

Configurable Passband Imaging Spectrometer Based on Acousto-optic Tunable Filter

2008

This work presents a new configurable imaging spectrometer called Autonomous Tunable Filtering System (ATFS). The system can be configured to acquire a single narrow spectral band, a composite multispectral image, or a broad pass-band. This flexibility is given by the use of an Acousto-Optic Tunable Filter (AOTF) driven by a programmable radio frequency (rf) signal generator. The AOTF acts as a light-diffraction element which output wavelength is selected by the frequency of an rf signal applied to it. The designed rf driver is based on a high-speed Digital-to-Analog converter, which can synthesize any composite rf waveform formed by a combination of sine signals. The images are formed thro…

Signal generatorbusiness.product_categoryComputer sciencebusiness.industryMultispectral imageImaging spectrometerPhysics::OpticsFilter (signal processing)OpticsWaveformRadio frequencyArtificial intelligencebusinessPassbandDigital camera
researchProduct

A method for quantifying atrial fibrillation organization based on wave-morphology similarity

2002

A new method for quantifying the organization of single bipolar electrograms recorded in the human atria during atrial fibrillation (AF) is presented. The algorithm relies on the comparison between pairs of local activation waves (LAWs) to estimate their morphological similarity, and returns a regularity index (/spl rho/) which measures the extent of repetitiveness over time of the detected activations. The database consisted of endocardial data from a multipolar basket catheter during AF and intraatrial recordings during atrial flutter. The index showed maximum regularity (/spl rho/=1) for all atrial flutter episodes and decreased significantly when increasing AF complexity as defined by W…

Signal processingBundle of Hismedicine.medical_specialtyMorphological similarityAtrial fibrillation (AF)Biomedical EngineeringSensitivity and SpecificityPattern Recognition AutomatedElectrocardiographySimilarity (network science)Heart RateInternal medicineAtrial Fibrillationotorhinolaryngologic diseasesmedicineHumansClinical treatmentWaveform morphologyMathematicsmedicine.diagnostic_testMinimum distanceModels CardiovascularReproducibility of ResultsSignal Processing Computer-AssistedAtrial fibrillationEndocardial signalmedicine.diseaseTachyarrhythmia organizationCardiologysense organsRhythm classificationBasket catheterElectrocardiographyAlgorithmsAtrial flutterBiomedical engineeringIEEE Transactions on Biomedical Engineering
researchProduct