Search results for "Width"

showing 10 items of 690 documents

Room-Temperature X-ray response of cadmium-zinc-Telluride pixel detectors grown by the vertical Bridgman technique

2020

In this work, the spectroscopic performances of new cadmium–zinc–telluride (CZT) pixel detectors recently developed at IMEM-CNR of Parma (Italy) are presented. Sub-millimetre arrays with pixel pitch less than 500 µm, based on boron oxide encapsulated vertical Bridgman grown CZT crystals, were fabricated. Excellent room-temperature performance characterizes the detectors even at high-bias-voltage operation (9000 V cm−1), with energy resolutions (FWHM) of 4% (0.9 keV), 1.7% (1 keV) and 1.3% (1.6 keV) at 22.1, 59.5 and 122.1 keV, respectively. Charge-sharing investigations were performed with both uncollimated and collimated synchrotron X-ray beams with particular attention to the mitigation o…

Nuclear and High Energy PhysicsPhotonMaterials scienceCdZnTe pixel detectorDot pitchCollimated lightCharge sharinglaw.inventionspectroscopic X-ray imagingchemistry.chemical_compoundlawcharge losseInstrumentationRadiationcharge sharingbusiness.industrySettore FIS/01 - Fisica SperimentaleX-raySynchrotronSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Cadmium zinc tellurideFull width at half maximumCdZnTe pixel detectors; charge losses; charge sharing; spectroscopic X-ray imaging; vertical Bridgman technique; X-ray and gamma-ray detectorsX-ray and gamma-ray detectorschemistryOptoelectronicsvertical Bridgman techniquebusinessX-ray and gamma-ray detector
researchProduct

Energy calibration of the NEXT-White detector with 1% resolution near Q ββ of 136Xe

2019

Excellent energy resolution is one of the primary advantages of electroluminescent high pressure xenon TPCs, and searches for rare physics events such as neutrinoless double-beta decay ($\beta\beta0\nu$) require precise energy measurements. Using the NEXT-White detector, developed by the NEXT (Neutrino Experiment with a Xenon TPC) collaboration, we show for the first time that an energy resolution of 1% FWHM can be achieved at 2.6 MeV, establishing the present technology as the one with the best energy resolution of all xenon detectors for $\beta\beta0\nu$ searches.

Nuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsPhysical measurementsPhysics::Instrumentation and DetectorsDark Matter and Double Beta DecayFísica -- Mesuramentschemistry.chemical_elementBioengineeringAtomic01 natural sciencesMathematical SciencesNuclear physicsParticle and Plasma PhysicsXenonAffordable and Clean Energy0103 physical sciencesDark Matter and Double Beta Decay (experiments)CalibrationNuclearlcsh:Nuclear and particle physics. Atomic energy. RadioactivityCalibratge010306 general physicsMathematical PhysicsPhysicsQuantum Physics010308 nuclear & particles physicsDetectorResolution (electron density)MolecularDetectorsNuclear & Particles PhysicsFull width at half maximumchemistryBeta (plasma physics)Physical SciencesCalibrationlcsh:QC770-798High Energy Physics::ExperimentNeutrinoEnergy (signal processing)
researchProduct

Detector characterization and first coincidence tests of a Compton telescope based on LaBr3 crystals and SiPMs

2011

International audience; A Compton telescope for dose monitoring in hadron therapy consisting of several layers of continuous LaBr3 crystals coupled to silicon photomultiplier (SiPM) arrays is under development within the ENVISION project. In order to test the possibility of employing such detectors for the telescope, a detector head consisting of a continuous 16 mm×18 mm×5 mm LaBr3 crystal coupled to a SiPM array has been assembled and characterized, employing the SPIROC1 ASIC as readout electronics. The best energy resolution obtained at 511 keV is 6.5% FWHM and the timing resolution is 3.1 ns FWHM. A position determination method for continuous crystals is being tested, with promising res…

Nuclear and High Energy PhysicsPhysics::Instrumentation and DetectorsCompton telescopeSiPM01 natural sciences7. Clean energyCoincidence030218 nuclear medicine & medical imaginglaw.inventionTelescope03 medical and health sciencesHadron therapy0302 clinical medicineOpticsSilicon photomultiplierApplication-specific integrated circuitlaw0103 physical sciencesCompton imaging[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det][SPI.NANO]Engineering Sciences [physics]/Micro and nanotechnologies/MicroelectronicsInstrumentationPhysicsContinuous crystal010308 nuclear & particles physicsbusiness.industryResolution (electron density)DetectorMPPCG-APDLaBr3Full width at half maximumbusiness
researchProduct

Development of new CdZnTe detectors for room-temperature high-flux radiation measurements

2017

Recently, CdZnTe (CZT) detectors have been widely proposed and developed for room-temperature X-ray spectroscopy even at high fluxes, and great efforts have been made on both the device and the crystal growth technologies. In this work, the performance of new travelling-heater-method (THM)-grown CZT detectors, recently developed at IMEM-CNR Parma, Italy, is presented. Thick planar detectors (3 mm thick) with gold electroless contacts were realised, with a planar cathode covering the detector surface (4.1 mm × 4.1 mm) and a central anode (2 mm × 2 mm) surrounded by a guard-ring electrode. The detectors, characterized by low leakage currents at room temperature (4.7 nA cm−2 at 1000 V cm−1), a…

Nuclear and High Energy PhysicsPreamplifier02 engineering and technologydigital pulse shape analysiRadiation01 natural scienceslaw.inventionPlanarOpticstravelling heater methodlaw0103 physical scienceshigh fluxInstrumentationenergy-resolved photon-counting detectorsNuclear and High Energy PhysicPhysicsRadiationdigital pulse shape analysis010308 nuclear & particles physicsbusiness.industryCdZnTe detectorsCdZnTe detectorDetectorSettore FIS/01 - Fisica SperimentaleX-ray and γ-ray detectorenergy-resolved photon-counting detector021001 nanoscience & nanotechnologyCathodeSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Anodegold electroless contactFull width at half maximumX-ray and -ray detectors0210 nano-technologybusinessVoltage
researchProduct

High-resolution laser spectroscopy with the Collinear Resonance Ionisation Spectroscopy (CRIS) experiment at CERN-ISOLDE

2016

The Collinear Resonance Ionisation Spectroscopy (CRIS) experiment at CERN has achieved high-resolution resonance ionisation laser spectroscopy with a full width at half maximum linewidth of 20(1) MHz for 219;221Fr, and has measured isotopes as short lived as 5 ms with 214Fr. This development allows for greater precision in the study of hyperfine structures and isotope shifts, as well as a higher selectivity of singleisotope, even single-isomer, beams. These achievements are linked with the development of a new laser laboratory and new data-acquisition systems. publisher: Elsevier articletitle: High-resolution laser spectroscopy with the Collinear Resonance Ionisation Spectroscopy (CRIS) exp…

Nuclear and High Energy Physics[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]7. Clean energy01 natural scienceslaw.inventionLaser linewidthlawIonization0103 physical sciencesNuclear Physics - ExperimentLaser spectroscopy010306 general physicsSpectroscopyInstrumentationHyperfine structureLarge Hadron Collider010308 nuclear & particles physicsChemistryData acquisitionResonanceLaserIon beam purificationIsotope shiftFull width at half maximumHyperfine structureAtomic physicsNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

High performance detector head for PET and PET/MR with continuous crystals and SiPMs

2012

International audience; A high resolution PET detector head for small animal PET applications has been developed. The detector is composed of a 12 mm x 12 mm source continuous LYSO crystal coupled to a 64-channel monolithic SiPM matrix from FBK-irst. Crystal thicknesses of 5 mm and 10 mm have been tested, both yielding an intrinsic spatial resolution around 0.7 mm FWHM with a position determination algorithm that can also provide depth-of-interaction information. The detectors have been tested in a rotating system that makes it possible to acquire tomographic data and reconstruct images of 22Na sources. An image reconstruction method specifically adapted for continuous crystals has been emp…

Nuclear and High Energy Physicsmedicine.medical_specialtySiPMIterative reconstruction01 natural sciencesParticle detectorLyso-030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsSilicon photomultiplier0103 physical sciencesmedicineMedical physicsHigh resolution[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det][SPI.NANO]Engineering Sciences [physics]/Micro and nanotechnologies/MicroelectronicsInstrumentationImage resolutionPhysics010308 nuclear & particles physicsbusiness.industryDetectorPosition determinationSemiconductor detectorFull width at half maximumMG-APDPETMonolithic crystalsbusiness
researchProduct

The laser and optical system for the RIBF-PALIS experiment

2017

Abstract This paper describes the laser and optical system for the Parasitic radioactive isotope (RI) beam production by Laser Ion-Source (PALIS) in the RIKEN fragment separator facility. This system requires an optical path length of 70 m for transporting the laser beam from the laser light source to the place for resonance ionization. To accomplish this, we designed and implemented a simple optical system consisting of several mirrors equipped with compact stepping motor actuators, lenses, beam spot screens and network cameras. The system enables multi-step laser resonance ionization in the gas cell and gas jet via overlap with a diameter of a few millimeters, between the laser photons an…

Nuclear and High Energy PhysicsspektroskopiaPhysics::Optics01 natural sciencesBeam parameter productlaw.inventionVertical-cavity surface-emitting laserLaser linewidthOpticslaw0103 physical sciencesPhysics::Atomic PhysicsLaser power scaling010306 general physicsInstrumentationPhysicsDistributed feedback laserta114010308 nuclear & particles physicsbusiness.industryFar-infrared lasergas cellLaserlasertekniikkaLaser Ion Sourcegas jetlaser spectroscopyPhysics::Accelerator PhysicsLaser beam qualitylaser resonance ionizationbusinessydinfysiikkaNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Evidence for narrow Δ0(1232) states in the 12 C(e,e'pπ−}11 C Reaction

1999

The reaction 12C(e,e'Δ0)11C →12C(e,e'pπ−)11C was investigated at the Mainz Microtron MAMI in a triple coincidence measurement using the three spectrometer setup of the A1 Collaboration. The good missing mass resolution of σm= 0.27 MeV/c2 allowed to select the events belonging to the ground state of 11C. Cutting on these events the excitation energy spectra of 12CΔ0 show evidence for two peaks of about 4 MeV width (FWHM) at 282 MeV and 296 MeV with a significance of about 4.5 standard deviations. The peaks are interpreted in a simple weak coupling model as bound Δ0 states in 12CΔ0.

Nuclear physicsPhysicsNuclear and High Energy PhysicsFull width at half maximumSpectrometerHadronNuclear fusionGround stateMicrotronExcitationSpectral lineThe European Physical Journal A
researchProduct

Test of lepton flavour universality in K+→ℓ+ν decays

2011

Abstract A precision test of lepton flavour universality has been performed by measuring the ratio R K of kaon leptonic decay rates K + → e + ν and K + → μ + ν in a sample of 59 813 reconstructed K + → e + ν candidates with ( 8.71 ± 0.24 ) % background contamination. The result R K = ( 2.487 ± 0.013 ) × 10 − 5 is in agreement with the Standard Model expectation.

Nuclear physicsPhysicsNuclear and High Energy PhysicsParticle physicsFlavourWidth ratioUniversality (dynamical systems)LeptonPhysics Letters B
researchProduct

Hypernuclear Spectroscopy at JLab Hall C

2010

Abstract Since the 1st generation experiment, E89-009, which was successfully carried out as a pilot experiment of (e,e'K+) hypernuclear spectroscopy at JLab Hall C in 2000, precision hypernuclear spectroscopy by the (e,e'K+) reactions made considerable progress. It has evolved to the 2nd generation experiment, E01-011, in which a newly constructed high resolution kaon spectrometer (HKS) was installed and the “Tilt method” was adopted in order to suppress large electromagnetic background and to run with high luminosity. Preliminary high-resolution spectra of 7 Λ He and 28 Λ Al together with that of 12 Λ B that achieved resolution better than 500 keV(FWHM) were obtained. The third generation…

Nuclear physicsPhysicsNuclear and High Energy PhysicsParticle physicsFull width at half maximumLuminosity (scattering theory)Electron spectrometerSpectrometerResolution (electron density)Calibrationhypernuclear; electroproduction; kaon spectrometer; electron spectrometerSpectroscopySpectral lineNuclear Physics A