Search results for "Width"

showing 10 items of 690 documents

Pressure tuning of light-induced superconductivity in K3C60

2017

Optical excitation at terahertz frequencies has emerged as an effective means to manipulate complex solids dynamically. In the molecular solid K3C60, coherent excitation of intramolecular vibrations was shown to transform the high temperature metal into a non-equilibrium state with the optical conductivity of a superconductor. Here we tune this effect with hydrostatic pressure, and we find it to disappear around 0.3 GPa. Reduction with pressure underscores the similarity with the equilibrium superconducting phase of K3C60, in which a larger electronic bandwidth is detrimental for pairing. Crucially, our observation excludes alternative interpretations based on a high-mobility metallic phase…

PhysicsSuperconductivityCondensed matter physicsStrongly Correlated Electrons (cond-mat.str-el)Terahertz radiationCondensed Matter - SuperconductivityBandwidth (signal processing)Hydrostatic pressureGeneral Physics and AstronomyFOS: Physical sciences02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesArticleSuperconductivity (cond-mat.supr-con)Condensed Matter - Strongly Correlated ElectronsMolecular solidPairingCondensed Matter::Superconductivity0103 physical sciencesPressure tuning010306 general physics0210 nano-technologyExcitationNature physics
researchProduct

Calibration of the NEXT-White detector using 83m Kr decays

2018

The NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. It has been operating at Laboratorio Subterr'aneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed using 83mKr decays during a long run taken from March to November 2017 (Run II). Krypton calibrations are used to correct for the finite drift-electron lifetime as well as for the dependence of the measured energy on the event transverse position which is caused by variations in solid angle coverage both for direct and reflected light and edge effects. After producing calibration maps to correct for …

PhysicsTime projection chamber010308 nuclear & particles physicsKryptonDetectorSolid anglechemistry.chemical_element01 natural sciencesNuclear physicsFull width at half maximumXenonchemistryDouble beta decay0103 physical sciencesCalibration010306 general physicsInstrumentationMathematical PhysicsJournal of Instrumentation
researchProduct

Inverse dispersion engineering in silicon waveguides

2014

We present a numerical tool that searches an optimal cross section geometry of silicon-on-insulator waveguides given a target dispersion profile. The approach is a gradient-based multidimensional method whose efficiency resides on the simultaneous calculation of the propagation constant derivatives with respect to all geometrical parameters of the structure by using the waveguide mode distribution. The algorithm is compatible with regular mode solvers. As an illustrative example, using a silicon slot hybrid waveguide with 4 independent degrees of freedom, our approach finds ultra-flattened (either normal or anomalous) dispersion over 350 nm bandwidth in less than 10 iterations.

PhysicsWaveguide (electromagnetism)Siliconbusiness.industryBandwidth (signal processing)Mathematical analysischemistry.chemical_elementInverseStatistical and Nonlinear PhysicsÒpticaAtomic and Molecular Physics and OpticsNonlinear systemOpticschemistryPropagation constantbusinessRefractive indexPhotonic-crystal fiber
researchProduct

Plasmonic Focusing Reduces Ensemble Linewidth

2012

In this chapter I present an effect the coating of gold nanorods with a silver shell is evocating: a reduction of the ensemble plasmon linewidth by changing the plasmon-shape relation, which connects the particle shape with its plasmon resonance wavelength. This change, we term “plasmonic focusing” (Sect. 10.2), leads to less variation of resonance wavelengths for the same particle size distribution. Section 10.3 explains the effect of increasing single particle linewidth during the coating process, which is therefore not the reason for the observed ensemble linewidth decrease. This is rather a result from a change in the plasmon-shape relation explained in Sect. 10.4. Using a simple model,…

PhysicsWavelengthLaser linewidthCondensed matter physicsParticle-size distributionPhysics::Atomic and Molecular ClustersPhysics::OpticsParticleNanorodSurface plasmon resonanceResonance (particle physics)Plasmon
researchProduct

THE LIMITING EFFICIENCY OF FOUR-BAND CELLS REVISITED

2014

The limiting theoretical efficiency of four-band solar cells is revisited. In previous work, researchers have looked at the theoretical efficiency of four band cells where the smallest of the three sub-band gaps is closest to the valence band and the largest closest to the conduction band. In this work, limits are calculated also for other possible band configurations. In multi-band cells, photon selectivity can be assured by adjusting the band widths. The present work shows that previous authors have put too rigid constraints on the band structure to achieve spectral selectivity. Relieving these constraints gives a considerably higher limiting efficiency for cells with band width restricti…

PhysicsWork (thermodynamics)PhotonBand gapbusiness.industryVDP::Technology: 500LimitingMolecular physicsMultiple exciton generationBand widthOptoelectronicssolar cells efficiency photovoltaicsDirect and indirect band gapsElectronic band structurebusiness
researchProduct

A rapid H? change in X Persei

1993

A trend of decreasing Hα emission over a period of thirty minutes is apparent in a series of spectra of X Persei taken on 31 December, 1987. This change appears to be astrophysical in origin and it indicates an anomalous state for X Persei that may be linked to its transition from a Be star to a normal B star, which occurred sometime between March 1988 and November 1990.

PhysicsX-ray astronomySpace and Planetary ScienceBe starStellar rotationAstronomyAstronomy and AstrophysicsH-alphaAstrophysicsEmission spectrumVariable starEquivalent widthMain sequenceAstrophysics and Space Science
researchProduct

Models and Astrophysical Parameters of High Mass X-ray Binaries

1996

The objective of this work is the High Mass X-ray Binaries. These systems consist of a neutron star orbiting around a star of spectral type OB. According to the luminosity class of the optical companion they split into Supergiant X-ray binaries and Be/X-ray systems. In both systems the high energy radiation is due to the accretion phenomenum, but in the first case the accreted metter comes from the strong stellar wind of the primary and in the second case it comes from the circumstellar envelope surrounding the Be star equator. In this work I concentrate on the optical and infrared bands of the electromagnetic spectrum although a discussion of the X-ray characteristics for some systems is a…

PhysicsX-ray bursterBe starAstrophysics::High Energy Astrophysical PhenomenaX-ray binaryPhotometric systemAstronomyAstronomy and AstrophysicsAstrophysics::Cosmology and Extragalactic AstrophysicsCircumstellar envelopeAstrophysicsLuminosityNeutron starSpace and Planetary ScienceAstrophysics::Solar and Stellar AstrophysicsAstrophysics::Earth and Planetary AstrophysicsEquivalent widthAstrophysics::Galaxy AstrophysicsPublications of the Astronomical Society of the Pacific
researchProduct

Development of the wide field imager for Athena

2015

The WFI (Wide Field Imager) instrument is planned to be one of two complementary focal plane cameras on ESA's next X-ray observatory Athena. It combines unprecedented survey power through its large field of view of 40 arcmin x 40 arcmin together with excellent count-rate capability (>= 1 Crab). The energy resolution of the silicon sensor is state-of-the-art in the energy band of interest from 0.2 keV to 15 keV, e.g. the full width at half maximum of a line at 6 keV will be <= 150 eV until the end of the nominal mission phase. This performance is accomplished by using DEPFET active pixel sensors with a pixel size of 130 μm x 130 μm well suited to the on-axis angular resolution of 5 arcsec of…

PhysicsX-ray detectorCMOS sensorHot and Energetic UniversePixelbusiness.industryElectronic Optical and Magnetic MaterialApplied MathematicsX-ray detectorComputer Science Applications1707 Computer Vision and Pattern Recognitionfocal plane cameraCondensed Matter PhysicX-ray astronomyFull width at half maximumCardinal pointOpticsActive pixel sensorObservatoryWFIAngular resolutionAthenaElectrical and Electronic EngineeringbusinessImage resolutionDEPFET
researchProduct

X-ray spectroscopy and dosimetry with a portable CdTe device.

2007

Abstract X-ray spectra and dosimetry information are very important for quality assurance (QA) and quality control (QC) in medical diagnostic X-ray systems. An accurate knowledge of the diagnostic X-ray spectra would improve the patient dose optimization, without compromising image information. In this work, we performed direct diagnostic X-ray spectra measurements with a portable device, based on a CdTe solid-state detector. The portable device is able to directly measure X-ray spectra at high photon fluence rates, as typical of clinical radiography. We investigated on the spectral performances of the system in the mammographic energy range (up to ∼40 keV). Good system response to monoener…

PhysicsX-ray spectroscopy CdTe detectorsNuclear and High Energy Physicsmedicine.medical_specialtyReproducibilitybusiness.industryDetectorExposure HVLFluenceFull width at half maximumQuality (physics)OpticsmedicineDosimetryMedical physicsSpectroscopybusinessInstrumentationHalf-value layer
researchProduct

Characterization of Al-Schottky CdTe detectors

2011

In the last decades, great efforts are being devoted to the development of CdTe detectors for high resolution X-ray and gamma ray spectroscopy. Recently, new rectifying contacts based on aluminum (Al) are very appealing in the development of CdTe detectors with low leakage currents and anode pixellization. In this work, we report on preliminary results of electrical and spectroscopic investigations on Schottky CdTe diode detectors (4.1 × 4.1 × 0.75 and 4.1 × 4.1 × 2 mm3) with Au/Ti/Al/CdTe/Pt electrode configuration. The detectors are characterized by very low leakage currents even at room temperature (26 pA at 25 °C under a bias voltage of −100 V for the 2 mm thick detector). Polarization …

PhysicsX-ray spectroscopySpectrometerbusiness.industrySettore FIS/01 - Fisica SperimentaleDetectorSchottky diodeBiasingSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)AnodeCdTe detectorFull width at half maximumX-ray and gamma ray spectroscopyOpticsOptoelectronicsGamma spectroscopybusiness2011 IEEE Nuclear Science Symposium Conference Record
researchProduct