Search results for "Width"
showing 10 items of 690 documents
Bottle microresonator with actively stabilized evanescent coupling
2011
The evanescent coupling of light between a whispering-gallery-mode bottle microresonator and a sub-wavelength-diameter coupling fiber is actively stabilized by means of a Pound-Drever-Hall technique. We demonstrate the stabilization of a critically coupled resonator with a control bandwidth of 0.1 Hz, yielding a residual transmission of (9 \pm 3) \times 10^-3 for more than an hour. Simultaneously, the frequency of the resonator mode is actively stabilized.
Low-dimensional iodide perovskite nanocrystals enable efficient red emission
2019
We report herein a simple ligand-assisted reprecipitation method at room temperature to synthesize mixed-cation hybrid organic–inorganic perovskite nanocrystals with low structural dimensionality.
Observation of Very Narrow Linewidths in the Fluorescence Excitation Spectra of Single Conjugated Polymer Chains at 1.2 K
2007
Fluorescence emission and excitation spectra of single poly[2-methoxy-5-(2'-ethyl-hexyloxy)-1,4-phenylene vinylene] polymer molecules embedded in poly(methylmethacrylate) have been recorded at 1.2 K. The ubiquitous spectral diffusion causes large variations in the spectral shape and apparent linewidth in the emission spectra. Nevertheless, we find very narrow (approximately 0.1 cm(-1)) purely electronic zero-phonon lines in the excitation spectra, which are 2 orders of magnitude smaller than previous estimates of the homogeneous linewidth. These results complement the molecular description of the low energy transitions in conjugated polymers.
Localized surface plasmon resonance sensor based on Ag-PVA nanocomposite thin films
2009
In this work we demonstrate the use of nanocomposite thin films of poly(vinyl alcohol) with embedded silver NPs for chemosensing purposes. Silver NPs are in situ synthesized inside polyvinyl alcohol during the bake step of the formation of a nanocomposite thin film. The polymer in the nanocomposite provides an appropriate chemical and electromagnetic environment for metal NPs in order to interact with and hence detect the chemical species. A limit of detection below 20 nM is found when detecting 2-mercaptoethanol as the analyte, when measuring spectral changes (peak wavelength, linewidth and intensity) in the Localized Surface Plasmon Resonance. Potential qualitative and semi-quantitative s…
3.5-μm bandwidth mid-infrared supercontinuum generation in a 2-cm long suspended-core chalcogenide fiber
2014
A supercontinuum source extending from 0.6 to 4.1 µm has been successfully generated in a 2-cm long As2S3 chalcogenide suspended-core fiber by means of a nJ-level 200-fs pumping at 2.5 µm.
Inverse dispersion design in silicon waveguides
2014
We present a numerical tool to find the cross-section geometry of silicon-oninsulator waveguides that leads to a target dispersion profile. In < 10 iterations, we achieve geometries providing ultraflattened dispersion over 350 nm bandwidth.
Constraining the pass-band of future space-based coronagraphs for observations of solar eruptions in the FeXIV 530.3 nm “green line”
2017
This research has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreement No 647214) and from the UK Science and Technology Facilities Council. Observations of the solar corona in the FeXIV 530.3 nm “green line” have been very important in the past, and are planned for future coronagraphs on-board forthcoming space missions such as PROBA-3 and Aditya. For these instruments, a very important parameter to be optimized is the spectral width of the band-pass filter to be centred over the “green line”. Focusing on solar eruptions, motions occurring along the line of sight will Doppler shift the line prof…
Direct Measurement of Mammographic X-Ray Spectra with a Digital CdTe Detection System
2012
In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate X-ray spectroscopy in mammography (1–30 keV). The DPP system performs a height and shape analysis of the detector pulses, sampled and digitized by a 14-bit, 100 MHz ADC. We show the results of the characterization of the detection system both at low and high photon counting rates by using monoenergetic X-ray sources and a nonclinical X-ray tube. The detection system exhibits excellent performance up to 830 kcps with an energy resolution of 4.5% FWHM at 22.1 keV. Direct measurements of clinical molybdenum X-ray spectra were carried out by using a pinhole…
A new approach to the Late Miocene-Early Pliocene forms of the genus Apocricetus. Apocricetus alberti (Rodentia, Mammalia) from Venta del Moro (Cabri…
2014
Abstract The species of the genus Apocricetus are considered to form the phyletic lineage A. aff. plinii (MN11)– A. plinii – A. alberti – A. barrierei – A. angustidens (MN16). Along this lineage, gradual morphological and biometrical changes occur, but not all the species are represented by rich populations. The assemblage of Apocricetus alberti from Venta del Moro is by far the most abundant collection of this species. This population shows a great morphological variability in some characters like the morphology of the anteroconid and the anterolophulids in m1 and the shape of the anterolophule in M1, with morphotypes that resemble both older and younger populations of Apocricetus . Along …
FLUMO: FLexible Underwater MOdem
2019
The last years have seen a growing interest in underwater acoustic communications because of its applications in marine research, oceanography, marine commercial operations, the offshore oil industry and defense. High-speed communication in the underwater acoustic channel has been challenging because of limited bandwidth, extended multipath, refractive properties of the medium, severe fading, rapid time variation and large Doppler shifts. In this paper, we show an implementation of a flexible Software-Defined Acoustic (SDA) underwater modem, where modulation parameters are completely tunable to optimize performance. In particular, we develop the system architecture following two key ideas. …