Search results for "Wrist"

showing 10 items of 67 documents

Zur erweitrten Indikationsstellung der Herbert-Schrauben-Osteosynthese

1995

Since 1984 the typical headless double threaded Herbert/Whipple screw is known in managing scaphoid fractures and scaphoid non-unions. We resume technical, biomechanical and histological aspects to point out advantages and disadvantages of this osteosynthesis. Our case review of 39 patients illustrate the same good results as achieved in treating scaphoid injuries, when using the Herbert/Whipple screw of a larger diameter for expanded indications other than scaphoid fractures, such as humeral- or radial-head fractures, Jones fractures and others.

Bone screwsOrthodonticsCarpal bonesmedicine.anatomical_structureOsteosynthesisbusiness.industrymedicineSurgeryKnee injuriesbusinessCase reviewWrist injuryHerbert screwUnfallchirurgie
researchProduct

Tactile input of the hand and the control of reaching to grasp movements

1997

The role of tactile information of the hand in the control of reaching to grasp movements was investigated. The kinematics of both reaching (or transport) and grasp components were studied in healthy subjects in two experimental conditions. In one condition (control condition) subjects were required to reach and grasp an object that could have two sizes and that could be located at two distances from the viewer. In the other condition (anaesthesia condition) the same movements were executed, but anaesthesia was provided to the subjects' fingertips. In both conditions vision of the hand was prevented during movement. Anaesthesia affected mainly the kinematics of the first phase of grasping, …

Computer scienceMovementmedia_common.quotation_subjectKinematicsanesthesiaSettore BIO/09maletouchMotor controllocalwristContrast (vision)Computer visionMovement; male; anesthesia local; psychomotor performance; fingers; hand strength; hand; wrist; touch; adult; humanshumansmedia_commonCommunicationProprioceptionbusiness.industryMovement (music)adultGeneral NeuroscienceMotor timingGRASPArm kinematicsMotor controlBody movementbody regionsDuration (music)Somatosensory systempsychomotor performancefingershand strengthhandArtificial intelligencebusinessHumanAnesthesia LocalExperimental Brain Research
researchProduct

A preliminary investigation of the effect of contact pressure on the accuracy of heart rate monitoring by wearable PPG wrist band

2019

The increase of safety and health monitor of workers has become a crucial objective to prevent excessive physical workloads, injuries, accidents and errors. Heart rate (HR) is a very important physiological indicator which could properly describe the workers’ physical status. Recently, wearable photoplethysmographic (PPG) wristband trackers have been utilized to measure HR without hindering normal gesture of workers. However, the quality of PPG signals is highly affected by human physical motions, resulting in a poor reliable HR estimation. Specifically, during different activities and gestures, PPG sensor contact pressures may have an impact on the quality of the heart rate signal. To appr…

Computer sciencePhotoplethysmography wearable sensor PPG sensor contact pressureWearable computerSettore ING-IND/34 - Bioingegneria IndustrialeWristSignalLoad cellSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di Macchinemedicine.anatomical_structureHeart rate monitoringHeart ratemedicineSettore ING-IND/12 - Misure Meccaniche E TermicheHeart rate variabilitysense organsContact pressureBiomedical engineering
researchProduct

A New Myohaptic Device to Assess Wrist Function in the Lab and in the Clinic – The Wristalyzer

2008

Wristalyzer is a portable robotic device combining haptic technology with electromyographic assessment. It allows to assess wrist motion in physiological and pathological conditions by applying loads and mechanical oscillations, taking into account the ergonomy and the angular positioning of the joints. The wristalyzer works in a free or loaded mode for assessment of metrics of motion and tremor, analyzes the behavior of the wrist joints and the associated muscle activities during delivery of mechanical oscillations, estimates the maximal voluntary contraction, assesses automatically the impedance of the wrist for assessment of rigidity or spasticity. Position, torques and electromyographic…

Computer scienceWristMotion (physics)body regionsVoluntary contractionmedicine.anatomical_structureWrist jointsmedicineSpasticitymedicine.symptomMuscle activityReliability (statistics)SimulationComputingMethodologies_COMPUTERGRAPHICSHaptic technology
researchProduct

Energy-related optimal control accounts for gravitational load: comparing shoulder, elbow, and wrist rotations.

2013

International audience; Gaveau J, Berret B, Demougeot L, Fadiga L, Pozzo T, Papaxanthis C. Energy-related optimal control accounts for gravitational load: comparing shoulder, elbow, and wrist rotations. J Neurophysiol 111: 4-16, 2014. First published October 16, 2013; doi: 10.1152/jn.01029.2012.-We permanently deal with gravity force. Experimental evidences revealed that moving against gravity strongly differs from moving along the gravity vector. This directional asymmetry has been attributed to an optimal planning process that optimizes gravity force effects to minimize energy. Yet, only few studies have considered the case of vertical movements in the context of optimal control. What kin…

DYNAMICSAdultMaleGravity (chemistry)REPRESENTATIONShoulderRotationPhysiologyMovementTORQUE-CHANGE MODELContext (language use)[ SCCO.PSYC ] Cognitive science/PsychologyKinematicsRotationModels Biologicaloptimal controlFEEDBACK-CONTROLGRAVITYControl theoryElbowTorqueHumansgravity forceMathematicsdistal[SCCO.NEUR]Cognitive science/NeuroscienceGeneral NeuroscienceMOTOR ADAPTATIONWork (physics)reaching movementVertical planeWristBiomechanical PhenomenaJerkproximalSAGITTAL PLANE[SCCO.PSYC]Cognitive science/Psychology[ SCCO.NEUR ] Cognitive science/NeuroscienceThermodynamicsNEURAL-CONTROL[ SCCO ] Cognitive scienceTRAJECTORIESsensorimotor controlARM POINTING MOVEMENTSGravitation
researchProduct

Supplementing sleep actigraphy with button pressing while awake

2020

Objective/backgroundWrist-worn sleep actigraphs are limited for evaluating sleep, especially in sleepers who lie awake in bed without moving for extended periods. Sleep logs depend on the accuracy of perceiving and remembering times of being awake. Here we evaluated pressing an event-marker button while lying awake under two conditions: self-initiated pressing every 5 to 10 minutes or pressing when signaled every 5 minutes by a vibration pulse from a wristband. We evaluated the two conditions for acceptability and their concordance with actigraphically scored sleep.Participants and methodsTwenty-nine adults wore actigraphs on six nights. On nights 1 and 4, they pressed the marker to a vibra…

MaleTime FactorsPhysiologyTest StatisticsWalkingAudiologyMathematical and Statistical Techniques0302 clinical medicineMedicine and Health SciencesMusculoskeletal SystemClinical NeurophysiologyCognitive ImpairmentBrain MappingMultidisciplinaryCognitive NeurologyPhysicsQStatisticsRClassical MechanicsElectroencephalographyMiddle AgedWristElectrophysiologyArmsBioassays and Physiological AnalysisBrain ElectrophysiologyNeurologyPhysical SciencesMedicineFemaleSleep (system call)AnatomyResearch ArticleAdultmedicine.medical_specialtyImaging TechniquesScienceCognitive NeuroscienceNeurophysiologyNeuroimagingResearch and Analysis MethodsVibrationButton pressingEvery 5 minutesYoung Adult03 medical and health sciencesmedicineHumansWakefulnessStatistical MethodsAgedBiological Locomotionbusiness.industryElectrophysiological TechniquesBiology and Life SciencesActigraphyActigraphySleep scoringEvery Morning030228 respiratory systemBody LimbsCognitive ScienceSleep onset latencyClinical MedicineSleepPhysiological ProcessesbusinessMathematics030217 neurology & neurosurgeryNeurosciencePLOS ONE
researchProduct

The functional and radiographic outcomes following distal radius fracture treatment in a cast for 4 and 6 weeks in the elderly: A randomized trial.

2022

Background. The optimal duration of cast immobilization following distal radius fractures (DRFs) in elderly patients has not been established. Objectives. To assess the functional and radiological parameters following DRF treatment in elderly patients using 2 different periods of cast immobilization. Materials and methods. We assessed 50 patients (33 women and 17 men). The mean age at the beginning of treatment was 71 years. The mean duration of follow-up was 1 year and 3 months. One subgroup (n = 26) included patients treated with a cast for 4 weeks, whereas the other subgroup (n = 24) included patients treated with a cast for 6 weeks. The following measures were assessed: union rate, radi…

MaleWrist Jointdistal radius fractureMedicine (miscellaneous)PainelderlyGeneral Biochemistry Genetics and Molecular BiologyfunctionalFracture Fixation InternalTreatment OutcomeReviews and References (medical)Internal MedicineHumansPharmacology (medical)radiographicFemaleRange of Motion ArticularRadius FracturesGenetics (clinical)AgedAdvances in clinical and experimental medicine : official organ Wroclaw Medical University
researchProduct

Diagnostic Value of Optical Spectral Transmission in Rheumatoid Arthritis: Associations with Clinical Characteristics and Comparison with Joint Ultra…

2020

Objective.To examine the value of optical spectral transmission (OST) in detecting joint inflammation in patients with rheumatoid arthritis (RA) and to evaluate whether OST correlates with certain patient characteristics.Methods.OST measurements were performed in the metacarpophalangeal, proximal intraphalangeal, and wrist joints of 168 patients with RA and 114 controls. OST difference between the 2 groups was statistically examined and subsequently controlled for the effect of possible confounding factors. Diagnostic OST performance was tested by receiver-operating characteristics. Moreover, associations of OST with clinical and serological activity markers (patient group), joint ultrasoun…

MaleWrist Jointmedicine.medical_specialtySpectral transmissionImmunologySeverity of Illness IndexSpearman's rank correlation coefficientArthritis RheumatoidCorrelation03 medical and health sciences0302 clinical medicineRheumatologyInternal medicinemedicineHumansImmunology and Allergy030212 general & internal medicineUltrasonography030203 arthritis & rheumatologySynovitisbusiness.industryfungiUltrasoundConfoundingArea under the curveUltrasonography DopplerAnthropometrymedicine.diseaseRheumatoid arthritisFemalebusinessThe Journal of Rheumatology
researchProduct

Wrist-worn accelerometers in assessment of energy expenditure during intensive training

2012

We assessed the ability of the Polar activity recorder (AR) to measure energy expenditure (EE) during military training. Twenty-four voluntary male conscripts participated in the study and wore an AR on the non-dominant wrist 24 h a day for 7 d. The AR analyzed and stored the frequency of hand movements (f_hand) into memory at 1 min intervals. The relationship between f_hand and EE was studied over a 7 d period of military training using the doubly labeled water (DLW) technique. In addition, the relationship between f_hand and EE was analyzed during walking and running on a treadmill with an indirect calorimeter (IC), and f_hand was measured during a supervised 45 min field march test where…

Malemedicine.medical_specialtyPhysiologyBiomedical EngineeringBiophysicsDoubly labeled waterWalkingWristAccelerometerRunningYoung AdultPhysiology (medical)AccelerometrymedicineHumansTreadmillExercise physiologyExerciseMathematicsReproducibility of ResultsWristPhysical activity levelMilitary Personnelmedicine.anatomical_structureStandard errorEnergy expenditureExercise TestLinear ModelsPhysical therapyEnergy Metabolism
researchProduct

The incidence of hip, forearm, humeral, ankle, and vertebral fragility fractures in Italy: results from a 3-year multicenter study

2010

Introduction: We aimed to assess the incidence and hospitalization rate of hip and "minor" fragility fractures in the Italian population.Methods: We carried out a 3-year survey at 10 major Italian emergency departments to evaluate the hospitalization rate of hip, forearm, humeral, ankle, and vertebral fragility fractures in people 45 years or older between 2004 and 2006, both men and women. These data were compared with those recorded in the national hospitalizations database (SDO) to assess the overall incidence of fragility fractures occurring at hip and other sites, including also those events not resulting in hospital admissions.Results: We observed 29,017 fractures across 3 years, with…

Malemedicine.medical_specialtySettore MED/06 - Oncologia MedicaOsteoporosisImmunologyWristFractures BoneForearmCost of IllnessRheumatologymedicineSettore MED/33 - Malattie Apparato LocomotoreHumansImmunology and AllergyHumerusStatistics & numerical dataBoneAgedbusiness.industryhip fractures vertebral fracturesIncidence (epidemiology)Settore MED/34 - Medicina Fisica E RiabilitativaIncidenceAged; Cost of Illness; Female; Forearm Injuries; epidemiology/etiology; Fractures; Bone; Hip Injuries; Hospitalization; statistics /&/ numerical data; Humans; Humerus; injuries; Incidence; Italy; epidemiology; Male; Middle Aged; Osteoporosis; complications; Spinal Fracturesfragility fractures; osteoporosisfragility fracturesForearm InjuriesHumerusMiddle Agedmedicine.diseaseMale; Middle Aged; Hip Injuries; Humerus; Spinal Fractures; Cost of Illness; Female; Forearm Injuries; Italy; Hospitalization; Humans; Osteoporosis; Fractures Bone; Aged; IncidenceSurgeryHospitalizationmedicine.anatomical_structureItalyOrthopedic surgeryPhysical therapyOsteoporosisSpinal FracturesFemaleAnklebusinessFracturesHip InjuriesResearch ArticleArthritis Research & Therapy
researchProduct