Search results for "X-Ray"

showing 10 items of 4234 documents

Effects of high-pressure on the structural, vibrational, and electronic properties of monazite-type PbCrO4

2012

We have performed an experimental study of the crystal structure, lattice dynamics, and optical properties of PbCrO 4 (the mineral crocoite) at ambient and high pressures. In particular, the crystal structure, Raman-active phonons, and electronic band gap have been accurately determined. X-ray-diffraction, Raman, and optical absorption experiments have allowed us also to completely characterize two pressure-induced structural phase transitions. The first transition is from a monoclinic structure to another monoclinic structure. It maintains the symmetry of the crystal but has important consequences in the physical properties; among others, a band-gap collapse is induced. The second one invo…

CrocoiteZirconMaterials scienceOrthophosphatesFOS: Physical sciencesElectronic structureCrystal structureType (model theory)CrystalPhysics - Geophysicssymbols.namesakeCrocoitePhysics - Chemical PhysicsCrystalChemical Physics (physics.chem-ph)Condensed Matter - Materials ScienceCondensed matter physicsMetalTemperatureMaterials Science (cond-mat.mtrl-sci)SpectraCondensed Matter PhysicsElectronic Optical and Magnetic MaterialsGeophysics (physics.geo-ph)FISICA APLICADAX-ray crystallographyTransitionsymbolsRaman spectroscopySrCrO4Monoclinic crystal system
researchProduct

Large retroperitoneal abscess extended to the inferior right limb secondary to a perforated ileal Crohn’s disease: the importance of the multidiscipl…

2016

The typical complications of Crohn's disease concerns small and large bowel. The full thickness inflammation of the intestinal wall develops in strictures, fistulas and abdominal abscesses. Nowadays the most accepted therapeutic for intra-abdominal abscess option is antibiotic therapy and, in case of need, percutaneous drainage of the abscess. If the abscess passes through the pelvic foramen the abscess can involve the inferior limbs. We report a case a perforation of terminal ileum in Crohn's disease complicated by a large abscess of the right iliac fossa reaching the spaces between the anterior lateral muscles of the right thigh as far as the anterior lateral pre-tibial region. We discuss…

Crohn’s diseaseMalemedicine.medical_treatment030230 surgeryInflammatory bowel disease0302 clinical medicineCrohn DiseaseLaparotomyFasciitisAbscessCrohn's diseasePeritonitiCoinfectionIleal DiseasesAbdominal Abscessmedicine.anatomical_structureIleal DiseaseDrainage030211 gastroenterology & hepatologyAneurysm FalseHumanAdultReoperationmedicine.medical_specialtyAbdominal AbscessSepsiPerforation (oil well)Iliac fossaContext (language use)PeritonitisClinical Practice03 medical and health sciencesSepsismedicineHumansRetroperitoneal SpaceRight ThighLaparotomyLegbusiness.industryAbdominal AbsceFasciitimedicine.diseasebacterial infections and mycosesSurgeryRetroperitoneal absceIntestinal PerforationInterdisciplinary CommunicationbusinessTomography X-Ray ComputedComplication
researchProduct

The TES-based cryogenic anticoincidence detector for IXO: First results from large area prototypes

2010

The technique which combines high resolution spectroscopy with imaging capability is a powerful tool to extract fundamental information in X-ray Astrophysics and Cosmology. TES (Transition Edge Sensors)-based microcalorimeters match at best the requirements for doing fine spectroscopy and imaging of both bright (high count rate) and faint (poor signal-to-noise ratio) sources. For this reason they are considered among the most promising detectors for the next high energy space missions and are being developed for use on the focal plane of the IXO (International X-ray Observatory) mission. In order to achieve the required signal-to-noise ratio for faint or diffuse sources it is necessary to r…

Cryogenic Detectors; IXO; SQUID; TES; X-ray; Electronic Optical and Magnetic Materials; Condensed Matter Physics; Computer Science Applications1707 Computer Vision and Pattern Recognition; Applied Mathematics; Electrical and Electronic EngineeringCryogenic DetectorsSQUIDSpace explorationX-raySignal-to-noise ratioOpticsSettore FIS/05 - Astronomia E AstrofisicaObservatoryElectronicOptical and Magnetic MaterialsElectrical and Electronic EngineeringPhysicsSpectrometerPixelbusiness.industryApplied MathematicsDetectorPulse durationComputer Science Applications1707 Computer Vision and Pattern RecognitionCondensed Matter PhysicsCardinal pointIXObusinessTES Cryogenic Detectors X-ray SQUID IXOTES
researchProduct

Baseline design of the thermal blocking filters for the X-IFU detector on board ATHENA

2014

ATHENA is an advanced X-ray observatory designed by a large European consortium to address the science theme "Hot and Energetic Universe" recently selected by ESA for L2 – the second Large-class mission within the Cosmic Vision science program (launch scheduled in 2028). One of the key instruments of the mission is the X-ray Integral Field Unit (X-IFU), an array of Transition Edge Sensor (TES) micro-calorimeters with high energy resolution (2.5 eV @ 6 keV) in the energy range 0.2÷12 keV, operating at the focal plane of a large effective area high angular resolution (5" HEW) grazing incidence X-ray telescope. The X-IFU operates at temperatures below 100 mK and thus requires a sophisticated c…

CryostatCosmic VisionVisionShieldsX-ray telescopeGrazing incidencelaw.inventionTelescopeOpticsSettore FIS/05 - Astronomia E AstrofisicalawX-raysElectronicmicro-calorimeterOptical and Magnetic MaterialsElectrical and Electronic EngineeringX-ray telescopesPhysicsX-IFUSpatial resolutionSounding rocketEquipment and servicesbusiness.industrySensorsApplied MathematicsDetectorAstrophysics::Instrumentation and Methods for AstrophysicsOptical Blocking FiltersComputer Science Applications1707 Computer Vision and Pattern RecognitionDetector arraysCondensed Matter PhysicsATHENAmissionsCultural heritageTransition edge sensorbusinessATHENA; micro-calorimeter; missions; Optical Blocking Filters; X-IFU; X-rays; Electronic Optical and Magnetic Materials; Condensed Matter Physics; Computer Science Applications1707 Computer Vision and Pattern Recognition; Applied Mathematics; Electrical and Electronic EngineeringTelescopes
researchProduct

Radio frequency shielding of thin aluminized plastic filters investigated for the ATHENA X-IFU detector

2018

Copyright 2018 Society of Photo-Optical Instrumentation Engineers (SPIE). One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited. The X-ray Integral Field Unit (X-IFU) is one of the two detectors of the ATHENA astrophysics space mission approved by ESA in the Cosmic Vision 2015-2025 Science Programme. The X-IFU consists of a large array of transition edge sensors (TES) micro-calorimeters covering a field of view of 5' diameter, sensitive in the energy range 0.2-12 keV, and providing a spectral resolution…

CryostatMaterials sciencePhysics::Instrumentation and DetectorsX-ray detectorRF attenuationField of viewCondensed Matter Physic02 engineering and technologyreverberation chamber7. Clean energyElectromagnetic interferenceSettore FIS/05 - Astronomia E AstrofisicaOpticsX-ray Integral Field Unit (X-IFU)thermal thin-film filter0202 electrical engineering electronic engineering information engineeringElectrical and Electronic Engineeringbusiness.industryElectronic Optical and Magnetic Material020502 materialsDetectorAstrophysics::Instrumentation and Methods for Astrophysicsx-ray detectorComputer Science Applications1707 Computer Vision and Pattern Recognition020206 networking & telecommunicationsresonance modeApplied MathematicATHENA X-ray observatoryEMI shielding0205 materials engineeringElectromagnetic shieldingRadio frequencyAntenna (radio)businessSpace Telescopes and Instrumentation 2018: Ultraviolet to Gamma Ray
researchProduct

The focal plane assembly for the Athena X-ray Integral Field Unit instrument

2016

This paper summarizes a preliminary design concept for the focal plane assembly of the X-ray Integral Field Unit on the Athena spacecraft, an imaging microcalorimeter that will enable high spectral resolution imaging and point-source spectroscopy. The instrument's sensor array will be a ~ 3840-pixel transition edge sensor (TES) microcalorimeter array, with a frequency domain multiplexed SQUID readout system allowing this large-format sensor array to be operated within the thermal constraints of the instrument's cryogenic system. A second TES detector will be operated in close proximity to the sensor array to detect cosmic rays and secondary particles passing through the sensor array for off…

CryostatPhysics::Instrumentation and DetectorsAperture01 natural sciencesfrequency division multiplexingfocal plane assemblySettore FIS/05 - Astronomia E AstrofisicaOpticsSensor array0103 physical sciencesElectronicSQUID amplifierAthenaOptical and Magnetic MaterialsElectrical and Electronic Engineeringta216010306 general physicsta113010302 applied physicsPhysicsX-IFUta114ta213business.industryStray lightApplied Mathematicstransition edge sensorDetectorAstrophysics::Instrumentation and Methods for AstrophysicsX-ray microcalorimeterComputer Science Applications1707 Computer Vision and Pattern RecognitionCondensed Matter PhysicsCardinal pointElectromagnetic shieldingcryogenic anti-coincidence detectorX-ray microcalorimeter transition edge sensor cryogenic anti-coincidence detector SQUID amplifier frequency division multiplexing Athena X-IFU focal plane assemblyTransition edge sensorbusinessAthena; cryogenic anti-coincidence detector; focal plane assembly; frequency division multiplexing; SQUID amplifier; transition edge sensor; X-IFU; X-ray microcalorimeter; Electronic Optical and Magnetic Materials; Condensed Matter Physics; Computer Science Applications1707 Computer Vision and Pattern Recognition; Applied Mathematics; Electrical and Electronic EngineeringSPIE Proceedings
researchProduct

Thermal Filters for the ATHENA X-IFU: Ongoing Activities Toward the Conceptual Design

2016

ATHENA is the L2 mission selected by ESA to pursue the science theme “Hot and Energetic Universe.” One of the two focal plane instruments is the X-ray Integral Field Unit, an array of TES microcalorimeters operated at T $$<$$ 100 mK. To allow the X-ray photons focused by the telescope to reach the detector, windows have to be opened on the cryostat thermal shields. X-ray transparent filters need to be mounted on these open windows to attenuate the IR radiation from warm surfaces, to attenuate RF electromagnetic interferences on TES sensors and SQUID electronics, and to protect the detector from contamination. This paper reviews the ongoing activities driving the design of the X-IFU thermal …

CryostatX-ray AstronomyAtomic and Molecular Physics and OpticATHENA; Thermal Filters; X-IFU; X-ray Astronomy; Condensed Matter Physics; Atomic and Molecular Physics and Optics; Materials Science (all)ShieldsCondensed Matter Physic01 natural sciencesThermal Filterlaw.invention010309 opticsTelescopeATHENA; Thermal Filters; X-IFU; X-ray Astronomy; Atomic and Molecular Physics and Optics; Materials Science (all); Condensed Matter PhysicsOpticsSettore FIS/05 - Astronomia E AstrofisicaConceptual designlawAtomic and Molecular Physics0103 physical sciencesGeneral Materials ScienceElectronics010303 astronomy & astrophysicsThermal FiltersPhysicsX-ray astronomyX-IFUbusiness.industryDetectorCondensed Matter PhysicsAtomic and Molecular Physics and OpticsATHENACardinal pointMaterials Science (all)and Opticsbusiness
researchProduct

Preliminary studies on the synthesis of alkaline-free large crystals of ZSM-5

1988

Single crystals of ZSM-5 were synthesized in three systems containing Na + -TPA, Li + -TPA, and NH 4 + -TPA, respectively. Applying a reaction mixture of the molar composition 8 TPA + 123(NH 4 ) 2 O + Al 2 O 3 + 59 SiO 2 + 2280 H 2 O, alkaline-free, homogeneous, and pure single crystals of ZSM-5 were prepared up to a length of 350 μm. The crystal size and yield were found to be dependent on the water content of the starting reaction mixture and on the type of aluminium source; for example, boehmite and aluminiumtriisopropylate.

CrystalBoehmiteCrystallographychemistryAluminiumYield (chemistry)X-ray crystallographychemistry.chemical_elementQualitative inorganic analysisZSM-5Single crystalGeneral Environmental ScienceNuclear chemistryZeolites
researchProduct

An improved goniometer head for high-temperature single-crystal X-ray diffraction

1999

A reliable and inexpensive goniometer head has been designed. Its stability, resulting from its compact construction, makes it very suitable for accurate measurements. Moreover, its space-saving design facilitates its application in X-ray data collection using charge-coupled device (CCD) detectors. This head has been improved for high-temperature measurements and has been tested by comparison of accurate K0.88Rb0.12TiOPO4data collected both at room temperature and at 973 K on the same crystal. The excellent structure results obtained at 973 K during the 360 h of measurements prove the stability of the goniometer head.

CrystalCrystallographyOpticsbusiness.industryChemistryGoniometerDetectorX-ray crystallographyHead (vessel)businessSingle crystalGeneral Biochemistry Genetics and Molecular BiologyJournal of Applied Crystallography
researchProduct

X-ray-absorption spectroscopy ofNd3+-exchanged β-alumina crystal

1996

The results of x-ray-absorption spectroscopy investigations of ${\mathrm{Nd}}^{3+}$ ions in a nearly fully exchanged (93%) sodium \ensuremath{\beta}-alumina crystal are reported. The ${\mathrm{Nd}}^{3+}$ local environment is reconstructed using a multishell best fit procedure and is compared with existing structural models. The experimental extended x-ray-absorption fine-structure (EXAFS) spectra are also compared with model ab initio FEFF6 calculations based on the x-ray-diffraction data for the ${\mathrm{Nd}}^{3+}$ ions located at the BR(2d) and interstitial A(6h) sites of \ensuremath{\beta}-alumina. Neodymium ions are mainly found near the BR(2d) sites of the conduction plane, where they…

CrystalPhysicsCrystallographyX-ray absorption spectroscopychemistryExtended X-ray absorption fine structureAb initiochemistry.chemical_elementSpectroscopyNeodymiumSpectral lineIonPhysical Review B
researchProduct