Calibration of the Lunar Orbital X-ray Fluorescence Imaging Spectrometer (LOXIA) of Chang'E-1 satellite at INAF-OAPA
2007
The Lunar Orbital X-ray Fluorescence Imaging Spectrometer (LOXIA) designed and constructed at the Institute of High Energy Physics of the Chinese Academy of Sciences to perform chemical composition analysis of the Moon surface will operate on-board the Chang'E-1 mission, the first Chinese lunar spacecraft to be launched in 2007. We report the main results of the calibration measurements that we have performed using the X-ray beamline of the XACT facility of INAFOsservatorio Astronomico di Palermo G.S. Vaiana to determine the quantum efficiency of the XRS detector in the soft X-rays as a function of photon energy and angle of incidence.
The Palermo XACT facility: a new 35 m long soft x-ray beam-line for the development and calibration of next-generation x-ray observatories
2006
The X-ray Astronomy Calibration and Testing (XACT) facility of the Instituto Nazionale di Astrofisica (INAF) at Osservatorio Astronomico di Palermo has recently undergone a major upgrade with the design and construction of a 35 meter long vacuum beam-line operating in the soft X-rays (0.1-20 keV) and the addition of new hardware to meet the requirements for testing and calibration of next generation X-ray missions. We report on the present configuration of the facility and briefly survey the range of its applications.
Time-dependent density-functional theory of strong-field ionization of atoms by soft x rays
2014
Under the terms of the Creative Commons Attribution License 3.0 (CC-BY).-- et al.
X-Ray Eclipse Time Delays in 4U2129+47
2007
4U 2129+47 was discovered in the early 80's and classified as an accretion disk corona source due to its broad and partial X-ray eclipses. The 5.24 hr binary orbital period was inferred from the X-ray and optical light curve modulation, implying a late K or M spectral type companion star. The source entered a low state in 1983, during which the optical modulation disappeared and an F8 IV star was revealed, suggesting that 4U 2129+47 might be part of a triple system. The nature of 4U 2129+47 has since been investigated, but no definitive conclusion has been reached. Here, we present timing and spectral analyses of two XMM-Newton observations of this source, carried out in May and June, 2005.…
Status of the EPIC thin and medium filters on-board XMM-Newton after more than 10 years of operation I: laboratory measurements on back-up filters
2013
After more than ten years of operation of the EPIC camera on board the X-ray observatory XMM-Newton, we have reviewed the status of its Thin and Medium filters by performing both laboratory measurements on back-up filters, and analysis of data collected in-flight. We have selected a set of Thin and Medium back-up filters among those still available in the EPIC consortium, and have started a program to investigate their status by different laboratory measurements including: UV/VIS transmission, X-ray transmission, RAMAN IR spectroscopy, X-Ray Photoelectron Spectroscopy, and Atomic Force Microscopy. We report the results of the measurements conducted up to now, and point out some lessons lear…
Preliminary radiation hardness tests of single photon Si detectors
2010
Single photon Si detectors were fabricated by STMicroelectronics and fully characterized in standard operation conditions and after irradiations. Both single cells and arrays, of dimensions ranging from 5x5 up to 64x64, were electrically tested. The devices operation was studied as a function of the temperature from -25 degrees C to 65 degrees C varying the voltage over breakdown, from 5% up to 20% of the breakdown voltage before and after irradiation using both light ions, 10 MeV B ions to doses in the range 3x10(7)-5x10(10) cm(-2), and X-rays irradiations in the range 0.5-20 krad(Si). Optical characterization was performed using a laser at 659 nm and opportunely chosen filters to vary the…
The filter wheel and filters development for the X-IFU instruments onboard Athena
2016
Athena is the large mission selected by ESA in 2013 to investigate the science theme “Hot and Energetic Universe” and presently scheduled for launch in 2028. One of the two instruments located at the focus of the 12 m-long Athena telescope is the X-ray Integral Field Unit (X-IFU). This is an array of TES microcalorimeters that will be operated at temperatures of 50 mK in order to perform high resolution spectroscopy with an energy resolution down to 2.5 eV at energies < 7 keV. In order to cope with the large dynamical range of X-ray fluxes spanned by the celestial objects Athena will be observing, the X-IFU will be equipped with a filter wheel. This will allow the user to fine tune the i…
On coronal structures and their variability in active stars: The case of Capella observed with Chandra/LETGS
2003
In this paper we present a detailed analysis of two X-ray spectra of Capella, taken eleven months apart with the Low Energy Transmission Grating Spectrometer (LETGS) of the Chandra Observatory. We have studied variability of the coronal emission over different time scales, both in the whole X-ray band and in narrow temperature ranges identified by lines. The comparison of the two observations shows that the whole coronal emission of Capella in March 2000 was 3% higher than in February 2001; there also appears to be a tendency, albeit a marginal one, for the hottest lines to show the largest changes between the two observations. A detailed search for short-term variability (on time scales ra…
GRB 070311: a direct link between the prompt emission and the afterglow
2007
We present prompt gamma-ray, early NIR/optical, late optical and X-ray observations of the peculiar GRB 070311 discovered by INTEGRAL, in order to gain clues on the mechanisms responsible for the prompt gamma-ray pulse as well as for the early and late multi-band afterglow of GRB 070311. We fitted with empirical functions the gamma-ray and optical light curves and scaled the result to the late time X-rays. The H-band light curve taken by REM shows two pulses peaking 80 and 140 s after the peak of the gamma-ray burst and possibly accompanied by a faint gamma-ray tail. Remarkably, the late optical and X-ray afterglow underwent a major rebrightening between 3x10^4 and 2x10^5 s after the burst …
Status of the EPIC thin and medium filters on-board XMM-Newton after more than 10 years of operation II: analysis of in-flight data
2013
After more than ten years of operation of the EPIC camera on board the X-ray observatory XMM-Newton we have reviewed the status of its thin and medium filters by performing both analysis of data collected in-flight and laboratory measurements on on-ground back-up filters. We have investigated the status of the EPIC thin and medium filters by performing an analysis of the optical loading in the PN offset maps to gauge variations in the optical and UV transmission of the filters. We both investigated repeated observations of single optically bright targets and performed a statistical analysis of the extent of loading versus visual magnitude at different epochs. We report the results of these …