Search results for "Xylenol"
showing 10 items of 12 documents
Interpretive optimisation strategy applied to the isocratic separation of phenols by reversed-phase liquid chromatography with acetonitrile–water and…
2000
An optimisation protocol is presented for the resolution of complex mixtures in isocratic RPLC with binary mobile phases of organic solvent and water, which is based on the prediction of peak position and shape of the individual compounds. A good description of the retention was achieved through the application of statistical weights to the widely used linear or quadratic relationships between the logarithm of the retention factor (log k) and the organic solvent concentration in the mobile phase. The maximisation of the product of peak purities for each compound is shown as a competitive resolution strategy versus the worst value of a selectivity parameter. Peak purities allow one to associ…
The impact of self-oxidation on the dosimetric performance of ferrous-sulfate/xylenol-orange gels
2015
Since their introduction in the 1980’s, most of the research on ferrous-sulfate gel dosimeters has aimed at minimizing the ferric ion diffusion phenomena that blur the 3D distribution of the signal. However, equally important are the spontaneous oxidation effects, which alter the sensitivity of the gels over time. In some gels, this effect is very pronounced and must be accounted for even when production, calibration and use of the gels are separated by just a few days. In other cases, the effect is much milder, but should still be properly accounted for when gels are used over a long period a time, such as in the proposed monitoring of adaptive radiotherapy treatments. Our work examined an…
Gel di Fricke: studio della risposta NMR in funzione della concentrazione di ferro ed utilizzo dosimetrico in ambito clinico (3D MRI)
2014
Novel GTA-PVA Fricke gels for three-dimensional dose mapping in radiotherapy
2017
Abstract One of the most recent and promising developments in radiotherapy dosimetry was the introduction of 3D radiation-sensitive gels. These gels present tissue equivalent composition and density, so they also serve as phantoms, and their response is largely independent of radiation quality and dose rate. Some gels are infused with ferrous sulfate and rely on the radiation-induced oxidation of ferrous ions to ferric ions (Fricke-gels). These formulations suffer from spontaneous-oxidation and diffusion of ferric ions after irradiation; chelating agents such as xylenol-orange significantly reduces the latter. Other gel types consist of dispersed monomers, and rely on radiation-induced cros…
Analysis of the response of PVA-GTA Fricke-gel dosimeters with clinical magnetic resonance imaging
2018
Abstract Fricke gel dosimeters produced with a matrix of Poly-vinyl alcohol (PVA) cross-linked with glutaraldehyde (GTA) were analyzed with magnetic resonance imaging (MRI). Previous studies based on spectrophotometry showed valuable dosimetric features of these gels in terms of X-ray sensitivity and diffusion of the ferric ions produced after irradiation. In this study, MRI was performed on the gels at 1.5 T with a clinical scanner in order to optimize the acquisition parameters and obtain high contrast between irradiated and non-irradiated samples. The PVA gels were found to offer good linearity in the range of 0–10 Gy and a stable signal for several hours after irradiation. The sensitivi…
Sviluppo e Applicazioni di nuovi materiali per la dosimetria delle radiazioni ionizzanti
The Research Activities carried out during the Three-year International PhD Course in Applied Physics of the candidate Salvatore Gallo had two main topics related to dosimetry of ionizing radiations (IR): the analysis of 3D gel dosimeters and the analysis of solid state dosimeters through electron spin resonance. Both these activities are focused on a careful study of new materials for the IR Dosimetry, both in terms of physical characterization of these new materials and of the optimization of readout methods for dosimetric measurements. The study performed through various techniques such as UV-Vis absorption spectroscopy, NMR Relaxometry, Magnetic Resonance Imaging (MRI) and Electron Spin…
Gel dosimeters for radiotherapy applications
2014
Study of optical absorbance and MR relaxation of irradiated Fricke Xylenol Orange Gel Dosimeters
2016
Studies on the optical absorbance spectra of Fricke xylenol orange gel dosimeters were performed, in the wavelength range from 300 nm to 800 nm, in order to highlight some particular characteristics that can affect the achievable precision. The spectra are different mainly due to the different types of xylenol orange that was used and to a lower extent due to the different gelling agents (agarose or gelatine). The characteristic of variation of absorbance spectra versus dose, however, are similar in the various cases and can explain some peculiarities, as apparent effects of dose threshold. Changes of spectral shapes appear over the time after irradiation. Magnetic resonance measurements pe…
Studio di assorbanza ottica e rilassometria RM in dosimetri a gel di Fricke
2016
I dosimetri a gel di Fricke con xylenol-orange, analizzati otticamente, presentano alcune limitazioni se impiegati per misure di basse dosi (pochi Gy o meno), per irraggiamenti di lunga durata o per individuare procedure di calibrazione che permettano l'utilizzo in radioterapia. Le difficoltà derivano da variazioni nello spettro di assorbanza verosimilmente dovute a variazioni dei legami degli ioni ferrici con lo xylenol-orange. Sono state effettuate misure: i) di assorbanza ottica, anche spettrometrica, per dosimetri irraggiati a diverse dosi e a diversi tempi rispetto all'irraggiamento; ii) di rilassometria RM per valutare le variazioni dovute al solo aumento del numero di ioni ferrici.
Study of optical absorbance and MR relaxation of Fricke xylenol orange gel dosimeters
2017
Abstract Studies on the optical absorbance spectra of Fricke xylenol orange gel dosimeters were performed, in the wavelength range from 300 nm to 800 nm, in order to highlight some particular characteristics that can affect the achievable precision. The spectra are different mainly due to the different types of xylenol orange that was used and to a lower extent due to the different gelling agents (agarose or gelatine). The characteristic of variation of absorbance spectra versus dose, however, are similar in the various cases and can explain some peculiarities, as apparent effects of dose threshold. Changes of spectral shapes appear over the time after irradiation. Magnetic resonance measur…