Search results for "Zernike polynomials"

showing 6 items of 16 documents

Optical Quality Comparison of Conventional and Hole-Visian Implantable Collamer Lens at Different Degrees of Decentering

2012

To compare the optical quality of implantable Collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering.Experimental laboratory investigation.Wavefront aberrations of the -3, -6, and -12 diopter (D) V4b and -3, -6, and -12 D V4c ICLs were measured in 3 conditions-centered and decentered 0.3 and 0.6 mm-at 3-mm and 4.5-mm pupils. The root mean square of total higher order aberrations, trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. In addition, point spread function and simulated retinal images of ICLs were calculated from the wavefront aberrations for each ICL and all conditions of decenteri…

Optics and PhotonicsPhakic Intraocular LensesCorneal Wavefront Aberrationgenetic structuresZernike polynomialsComa (optics)In Vitro TechniquesAstigmatismArtificial Lens Implant MigrationProsthesis DesignPhakic intraocular lensRetinasymbols.namesakeOpticsLens Implantation IntraocularmedicineHumansDioptreWavefrontPhysicsbusiness.industryAstigmatismModels Theoreticalmedicine.diseaseeye diseasesRefractive Surgical ProceduresOphthalmologySpherical aberrationAberrations of the eyesymbolsbusinessAmerican Journal of Ophthalmology
researchProduct

Visual acuity with computer simulated and lens-induced astigmatism

2014

[EN] The relationship between spherical and astigmatic refractive errors and their associated visual acuity is investigated in this work by means of two different approaches. In the first one, different refractive errors were induced in normal subjects by trial lenses. In the second one, defocused images were simulated numerically by the optical transfer function of a model eye and then judged by the same subjects. The amount of defocus (measured in terms of the modulus of the dioptric power vector) necessary to reduce the visual acuity to 0.1 logMAR and to 0.4 logMAR was computed with each method and then compared. We found that the visual system is clearly more tolerant to lens-induced de…

Visual acuitySimulated defocusFISICA APLICADAAstigmatismZernike polynomialsPower vectorvisual acuity simulated defocus astigmatism lens-induced defocus power vector Zernike polynomialsLens-induced defocus
researchProduct

Optical quality comparison between 2 collagen copolymer posterior chamber phakic intraocular lens designs

2014

Purpose To compare the optical quality in vitro of 2 designs of the Visian Implantable Collamer Lens phakic intraocular lens (pIOL) for different powers and optical apertures. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The Nimo TR1504 deflectometry device was used to measure the V4c pIOL, which has a smaller optic diameter, and the V5 pIOL, which has a larger optic diameter. The pIOLs were measured for −3.00 diopters (D), −6.00 D, −9.50 D, and −10.50 D at different optical apertures from 3.00 to 6.00 mm depending on the IOL power and model. The root mean square of higher-order aberrations (RMS HOAs) was analyzed. The Strehl ratio, point-spread functi…

WavefrontOptics and PhotonicsPhakic Intraocular LensesMaterials sciencePolymersApertureZernike polynomialsbusiness.industryStrehl ratioPupilProsthesis DesignRefraction OcularPhakic intraocular lensSensory SystemsRoot mean squareOphthalmologySpherical aberrationsymbols.namesakeOpticssymbolsHumansSurgeryCollagenbusinessDioptreJournal of Cataract and Refractive Surgery
researchProduct

Optical phase retrieval using four rotated versions of a single binary amplitude modulating mask

2019

In recent years, phase retrieval methods recovering the phase of an object from coded diffraction patterns have gained popularity. A numerical phase retrieval method called PhaseLift that recovers the phase of an object from a very limited number of coded diffraction patterns was recently proposed. Performance of PhaseLift has been analyzed for different types and the number of masks modulating an object. We present a unique application of PhaseLift that uses four rotations of a single mask, modulating only the amplitude of an object. In simulations, a phase screen with the root-mean-square (RMS) value 0.294  μm was used as the test object. The RMS value of the retrieved phase screen after …

WavefrontZernike polynomialsComputer scienceMechanical EngineeringPhase (waves)Astronomy and AstrophysicsWavefront sensor01 natural sciencesElectronic Optical and Magnetic Materials010309 opticssymbols.namesakeAmplitudeSpace and Planetary ScienceControl and Systems Engineering0103 physical sciencessymbolsPhase retrieval010303 astronomy & astrophysicsInstrumentationAlgorithmSmoothingPhase-shift keyingJournal of Astronomical Telescopes, Instruments, and Systems
researchProduct

Drifts in real-time partial wavefront correction and how to avoid them

2017

In visual experiments that require real-time partial correction of wavefront aberrations, small errors occur that accumulate over time and lead to drifts in Zernike coefficients of the uncorrected aberrations. A simple algorithm that does not require the inclusion of an additional optical path to obtain independent measurements of the eye's aberrations is described here, and its effectiveness in preventing these drifts is demonstrated.

Wavefrontgenetic structuresComputer sciencebusiness.industryZernike polynomialsMaterials Science (miscellaneous)Wavefront sensor01 natural scienceseye diseasesIndustrial and Manufacturing EngineeringDeformable mirror010309 optics03 medical and health sciencessymbols.namesake0302 clinical medicineOpticsOptical path0103 physical sciences030221 ophthalmology & optometrysymbolssense organsBusiness and International ManagementbusinessAdaptive opticsApplied Optics
researchProduct

Hardware Computation of Moment Functions in a Silicon Retina Using Binary Patterns

2006

International audience; We present in this paper a method for implementing moment functions in a CMOS retina for shape recognition applications. The method is based on the use of binary patterns and it allows the computation of different moment functions such geometric and Zernike moments of any orders by an adequate choice of the binary patterns. The advantages of the method over other methods described in the literature is that it is particularly suitable for the design of a programmable retina circuit where moment functions of different orders are obtained by simply loading the correct binary patterns into the memory devices implemented on the circuit. The moment values computed by the m…

Zernike polynomialsComputation[SPI.NANO] Engineering Sciences [physics]/Micro and nanotechnologies/MicroelectronicsBinary number02 engineering and technologyMethod of moments (statistics)symbols.namesake[ INFO.INFO-TI ] Computer Science [cs]/Image Processing0202 electrical engineering electronic engineering information engineeringComputer visionPattern matching[SPI.NANO]Engineering Sciences [physics]/Micro and nanotechnologies/MicroelectronicsRepresentation (mathematics)Mathematicsbusiness.industry020206 networking & telecommunicationsMoment (mathematics)[INFO.INFO-TI] Computer Science [cs]/Image Processing [eess.IV][INFO.INFO-TI]Computer Science [cs]/Image Processing [eess.IV]Pattern recognition (psychology)symbols020201 artificial intelligence & image processing[ SPI.NANO ] Engineering Sciences [physics]/Micro and nanotechnologies/MicroelectronicsArtificial intelligencebusinessAlgorithm
researchProduct