Search results for "absorption."
showing 10 items of 2682 documents
Vapor-phase introduction of alkyltin compounds in atomic absorption spectrophotometry
1990
Abstract Different systems for the introduction of alkyltin compounds in atomic absorption spectrophotometry using the vapor-phase introduction approach have been compared. Samples and standards were introduced in both quartz cell and flame atomizer using a vertical and a horizontal reactor. The better sensitivity was obtained with the quartz cell and the horizontal reactor.
Resolution of overlapped non-absorbing and absorbing solutes using either an absorption null-balance detection window or multivariate deconvolution a…
2004
Abstract Non-absorbing alkyl ether sulfates (AES) can be separated using anthraquinone-2-carboxylic acid (AQCA) as a probe; however, absorbing alkyl benzene sulfonates (ABS), if present, interfere indirect detection of most AES oligomers. Overcoming of this interference, as well as the simultaneous characterisation and evaluation of AES, fatty acids and ABS, was accomplished by using a diode-array detector and the procedures here discussed. First, it was shown that ABS can be made undetectable by using a 9 nm wide and 227 nm centred charge-absorptivity null-balance detection window (NBDW), where its contribution to the absorbance cancels the dilution effects that its presence induces on the…
Methylmercury and inorganic mercury determination in fish by cold vapour generation atomic absorption spectrometry
2000
Abstract Given that organic mercury is more dangerous than the inorganic form and that it is converted into methylmercury by biological methylation, we have studied and optimized a simple method for measuring both organic and inorganic mercury contents in fish, using a spectroscopic vapour generation technique, with a sequential reduction of the digested sample with stannous chloride and sodium tetrahydroborate. Prior to applying the method the sample was subjected to alkaline wet digestion. Due to the matrix interferences calibration curves with matrix addition were needed for mercury determinations. The analytical parameters of the method were: linearity from 10 to 200 ng of Hg in the red…
Arsenic content of Spanish cows' milk determined by dry ashing hydride generation atomic absorption spectrometry.
1994
SummaryThe arsenic content of cows' milk consumed in Spain was determined. A procedure using dry ashing hydride generation atomic absorption spectrometry was developed for the purpose. Experimental conditions for the destruction of organic matter were established and an interference study was carried out. The method developed has a detection limit of 0·1 ng/g, a relative SD of 5%, and a recovery (mean ± CSI) of 100 ± 4%. The accuracy of the method was checked by analysis of a certified sample of IAEA milk powder (mean ± CSI: certified, 4·85 ± 0·32 ng/g; found, 5·04 ± 0·81 ng/g). The proposed procedure was used to analyse cows' milk samples. The extremely low arsenic levels found do not pres…
Active alkaline traps to determine acidic-gas ratios in volcanic plumes: Sampling techniques and analytical methods
2014
In situ measurements have been the basis for monitoring volcanic gas emissions for many years and—being complemented by remote sensing techniques—still play an important role to date. Con- cerning in situ techniques for sampling a dilute plume, an increase in accuracy and a reduction of detection limits are still necessary for most gases (e.g., CO2, SO2, HCl, HF, HBr, HI). In this work, the Raschig-Tube tech- nique (RT) is modified and utilized for application on volcanic plumes. The theoretical and experimental absorption properties of the RT and the Drechsel bottle (DB) setups are characterized and both are applied simultaneously to the well-established Filter packs technique (FP) in the …
On-line bi-directional electrostacking for As speciation/preconcentration using electrothermal atomic absorption spectrometry.
2006
A method using bi-directional electrostacking (BDES) in a flow system is presented for As preconcentration and speciation analysis. Some parameters such as electrostacking time and applied voltage, support buffers and their concentrations were investigated. Boric acid plus sodium hydroxide at 0.1mol/l concentration was selected as support buffer to improve the pre-concentration factor (PF) for As(V). An analytical range from 2.0 to 50.0mugl(-1), and 0.35mugl(-1) as limit of detection, when applied 750V for 20min, were achieved. Under these conditions, a pre-concentration factor of 4.8 was obtained. The proposed method was applied to determine As(V) in mineral water and natural water samples…
Enhanced nanoscopy of individual CsPbBr3 perovskite nanocrystals using dielectric sub-micrometric antennas
2020
We demonstrate an efficient, simple, and low-cost approach for enhanced nanoscopy in individual green emitting perovskite (CsPbBr3) nanocrystals via TiO2 dielectric nanoantenna. The observed three- to five-fold emission enhancement is attributed to near-field effects and emission steering promoted by the coupling between the perovskite nanocrystals and the dielectric sub-micrometric antennas. The dark-field scattering configuration is then exploited for surface-enhanced absorption measurements, showing a large increase in detection sensitivity, leading to the detection of individual nanocrystals. Due to the broadband spectral response of the Mie sub-micrometric antennas, the method can be e…
Congenital secretory diarrhoea caused by activating germline mutations in GUCY2C
2016
Objective Congenital sodium diarrhoea (CSD) refers to a form of secretory diarrhoea with intrauterine onset and high faecal losses of sodium without congenital malformations. The molecular basis for CSD remains unknown. We clinically characterised a cohort of infants with CSD and set out to identify disease-causing mutations by genome-wide genetic testing. Design We performed whole-exome sequencing and chromosomal microarray analyses in 4 unrelated patients, followed by confirmatory Sanger sequencing of the likely disease-causing mutations in patients and in their family members, followed by functional studies. Results We identified novel de novo missense mutations in GUCY2C, the gene encod…
Chronic Diarrhea in a 5-Year-Old Girl: Pitfall in Routine Laboratory Testing with Potentially Severe Consequences
2009
A 5-year-old girl was referred because of recurrent watery diarrhea, abdominal pain, and flatulence. She was the second of 3 children. Her 10-year-old sister was normally developed and healthy. Her younger brother has meningomyelocele and hydrocephalus. At 1 year of age, the patient was admitted to the hospital for recurrent bronchitis, otitis media, food refusal, mild diarrhea, and abdominal distension since weaning. A sweat chloride analysis excluded cystic fibrosis. At that time, the patient’s laboratory results showed increased C-reactive protein (139 mg/L; reference interval, <5 mg/L) and moderate leukocytosis (14.6 × 109/L; reference interval, 4.5–13.5 × 109/L). Values for all other v…
Metabolic Consequences after Urinary Diversion
2014
Metabolic disturbances are well-known, but sometimes neglected immediate consequences or late sequelae following urinary diversion (UD) using bowel segments. Whereas subclinical disturbances appear to be quite common, clinically relevant metabolic complications, however, are rare. Exclusion of bowel segments for UD results in loss of absorptive surface for its physiological function. Previous studies demonstrated that at least some of the absorbtive and secreting properties of the bowel are preserved when exposed to urine.For each bowel segment typical consequences and complications have been reported. The use of ileal and/or colonic segments may result in hyperchloremic metabolic acidosis …