Search results for "accelerator"
showing 10 items of 1507 documents
Production of Exotic Nuclei via MNT Reactions Using Gas Cells
2020
The use of multi-nucleon transfer (MNT) reactions to produce neutron-rich nuclei in the heavy region has received an increased attention in the last decade. The feasibility of employing such reactions at the FRS Ion Catcher facility at GSI and the IGISOL facility at JYFL is studied using a combination of theoretical calculations and experiment simulations. The reactions are computed within a Langevin-type model, and the Geant program is used to simulate the transport of the resulting products within the experimental setups of the above-mentioned facilities. The angular distribution of ion release, possible target choices and target-to-beam-dump distances are discussed. peerReviewed
Measurement of radionuclide activities induced in target components of an IBA CYCLONE 18/9 by gamma-ray spectrometry with HPGe and LaBr3: Ce detector…
2014
Cyclotrons are used worldwide to produce radiopharmaceuticals by proton irradiation of a suitable target. The intense secondary neutron beam generated by proton interactions with the target induce high radionuclide activities in the target assembly parts that may result in an exposure to high dose levels of the operators during maintenance. The main goal of this work is to evaluate gamma-emitting radionuclide activities induced in Havar foils and titanium windows of a target assembly and carousel stripper forks of an IBA CYCLONE 18/9 cyclotron. The knowledge of radionuclide inventory for each component is required by many companies to assess risk for operators before waste handling and disp…
Mapping the Amplitude and Position Response of Double Sided Silicon Strip Detectors with Monocromatic Single Protons
2012
International audience; We are currently developing a novel detection system featuring high angular and energy resolution and able to reconstruct the particles momentum at high precision for different physical cases in multi-fragmentation nuclear physics experiments, based on Double Sided Silicon Strip Detectors as ΔE stages aimed at performing also pulse shape analysis for fragments stopping therein. We carried out a detailed qualification of the performance of the strip detectors. In order to provide the detector response matrix we used a pulsed monoenergetic proton beam. The paper reviews the pulsed proton beam facility of the LaBeC of INFN - Sezione di Firenze and present the results of…
Barkas effect with use of antiprotons and protons.
1989
The difference in the range of protons and antiprotons in matter, an example of the Barkas effect, is observed in a simple time-of-flight apparatus. The ranges of 5.9-MeV antiprotons and protons differ by about 6% in a degrader made predominantly of aluminum.
Photon Asymmetry of Deuteron Photodisintegration Between 160 and 410 MeV
1999
The photon asymmetry Σ of the reaction has been measured across the photon energy range 160–410 MeV at the Mainz Microtron MAMI. Linearly polarized photons were obtained from coherent bremsstrahlung and their energies were determined with the Glasgow tagging spectrometer. The large acceptance detector DAPHNE enabled the outgoing protons to be measured over the complete azimuthal range and for polar angles from 35° to 155° in the c.m. system. The data are compared with existing results and recent theoretical calculations.
Intense source of slow positrons from pulsed electron accelerators
1984
A pulsed LINAC is used for pair production in a tantalum target of 2.5 radiation lengths in an energy range from 80 to 260 MeV. Several well-annealed tungsten vanes are placed immediately behind the target and thermalize a small fraction of the fast positrons. The slow positrons are extracted from the target region and magnetically guided over a distance of 17 m to the detector at the end of an S-shaped solenoid. Two Nal detectors with well-known detection efficiency are used to register the 511 keV annihilationγ-rays. To reduce pile-up effects 50 mm of Pb were placed in front of the detectors. At an average electron current of 1 μA we could detect about 107 slow positrons per second. The p…
SU-E-T-218: Octavius 4D: Commissioning and Clinical Implementation of a New Device for VMAT Verifications
2013
Purpose: To commission a new device for pre‐treatment patient specific verification of VMAT plans, which is capable of reconstructing 3D dose with high resolution. Methods: Octavius 4D system (PTW) consists of an ion chamber array embedded in a cylindrical phantom which, assisted by an inclinometer, rotates synchronously with the gantry. For VMAT plans, it measures planar dose distributions as a function of gantry angle in order to compute the resulting 3D dose distribution. There are two options for the ion chamber array: Octavius 729 (general purpose) and Octavius 1000 SRS (small field size, high resolution). We have used three linacs: two Varian Clinac iX and one TrueBeam with MLC HD 120…
Neutrino flux prediction at MiniBooNE
2009
The booster neutrino experiment (MiniBooNE) searches for nu(mu)->nu(e) oscillations using the O(1 GeV) neutrino beam produced by the booster synchrotron at the Fermi National Accelerator Laboratory). The booster delivers protons with 8 GeV kinetic energy (8.89 GeV/c momentum) to a beryllium target, producing neutrinos from the decay of secondary particles in the beam line. We describe the Monte Carlo simulation methods used to estimate the flux of neutrinos from the beam line incident on the MiniBooNE detector for both polarities of the focusing horn. The simulation uses the Geant4 framework for propagating particles, accounting for electromagnetic processes and hadronic interactions in the…
Laser cooling of stored high-velocity ions by means of the spontaneous force
1993
A longitudinal laser cooling of ion beams at about 5% of the velocity of light has been performed at the Heidelberg Test Storage Ring with various cooling schemes employing the spontaneous force. For a 7.29-MeV $^{9}\mathrm{Be}^{+}$ beam with an initial longitudinal temperature of 2700 K, the main characteristics of laser cooling in a storage ring are discussed. When undamped, the transverse betatron oscillations of the coasting ions limit the longitudinal temperature after laser cooling to typically 1 K. After damping the transverse motion by precooling the ions with an electron cooler, longitudinal temperatures of below 30 mK have been obtained in the subsequent laser cooling. In this cas…
First measurement of the helicity-dependent γ p↦pη differential cross-section
2003
The helicity dependence of the (γ) over right arrow(p) over right arrow -+ peta reaction has been measured for the first time at a center-of-mass angle theta(eta)*= 70degrees in the photon energy range from 780 MeV to 790 MeV. The experiment, performed at the Mainz microtron MAMI, used a 4pi-detector system, a circularly polarized, tagged photon beam. and a longitudinally polarized frozen-spin target. The helicity 3/2 cross-section is found to be small and the results for helicity 1/2 agree with predictions from the MAID analysis.