Search results for "active power"
showing 10 items of 22 documents
Voltage Profile Improvement for Soc Son's Low-Voltage Grid with High Penetration of PV Systems by Optimizing the Location of SVC Devices
2018
This paper presents a method that is applied to optimize the placement of Static VAR compensators in a real low-voltage grid in the Vietnamese territory. In this way, the voltage profile of the distribution grid turns to be improved. A heuristic method, the Binary Particle Swarm Optimization, is used to find a solution to this problem within the Matlab environment. A case study that considers a high penetration of rooftop PV systems in a branch of Soc Son distribution grid is implemented to show the efficiency of the optimization method for this specific application.
Solar photovoltaic‑based microgrid hosting capacity evaluation in electrical energy distribution network with voltage quality analysis
2021
Abstract In this paper, solar photovoltaic hosting capacity within the electrical distribution network is estimated for different buses, and the impacts of high PV penetration are evaluated using power hardware-in-loop testing methods. It is observed that the considered operational constraints (i.e. voltage and loadings) and their operational limits have a significant impact on the hosting capacity results. However, with increasing photovoltaic penetration, some of the network buses reach maximum hosting capacity, which affects the network operation (e.g. bus voltages, line loading). The results show that even distributing the maximum hosting capacity among different buses can increase the…
The Measurement of Reactive Energy in Polluted Distribution Power Systems: An Analysis of the Performance of Commercial Static Meters
2008
This paper presents a comparative analysis of the performances of both a traditional induction meter and various types of commercial static meters for reactive energy in the presence of harmonic distortion. This is a topical issue, since there are several types of static meters on the market, based on different principles of construction. In accordance with current standards, these meters are designed to operate in sinusoidal conditions and their performance is not tested in the presence of harmonic distortion. However, with the increase of pollution levels in power systems, the meters may be used even in the presence of distorted voltages and/or currents; in such cases, their accuracy may …
A novel approach based on nonactive powers for the identification of disturbing loads in power systems
2007
In this paper, a new approach is proposed for the detection of harmonic sources in polluted power systems. It is a single- point strategy, based on a comparison among different "nonactive" power quantities proposed in literature that, in the same working conditions, assume different values at the same metering section. Some simulations tests were carried out on a standard IEEE test system proposed by other authors as a benchmark system for the analysis of multipoint measurement techniques for harmonic pollution monitoring. The obtained results show that the proposed single-point approach is in agreement with other strategies already proposed in the literature and can provide useful indicati…
Detection of disturbing loads in distorted and/or unbalanced power systems: a technique based on a comparison among nonactive powers
2007
This paper presents an innovative technique for the detection of disturbing loads in distorted power systems. It is a single-point strategy, based on a comparison among different "nonactive" power quantities already proposed in literature, that are measured at the same metering section. In the paper, the results obtained with the application of the proposed technique are compared with those of other techniques for the monitoring of the harmonic pollution, both single-point and multi-point. Moreover, the effectiveness of the strategy is discussed, considering also the errors of the measurement transducers.
Comparison of Nonactive Powers for the Detection of Dominant Harmonic Sources in Power Systems
2008
This paper deals with an innovative technique for the detection of disturbing loads in distorted power systems. The technique is a single-point strategy based on a comparison among different ldquononactiverdquo power quantities already proposed in the literature, which are measured at the same metering section. In this paper, the effectiveness of the strategy is discussed, which also considered the errors of the measurement transducers; the analysis is supported by simulation tests, which were carried out on both a simple single-phase system and an IEEE standard three-phase test power system. The latter was used by other authors as a benchmark system for the analysis of multipoint measureme…
Disturbing loads identification in power systems: a single-point time-domain method based on IEEE 1459-2000
2009
This paper presents a single-point method for the identification of prevailing disturbing loads in power systems for both single-phase and three-phase applications downstream or upstream from the metering section. It is based on the simultaneous measurement of three nonactive power quantities, which are based on the IEEE Std. 1459-2000 approach. The proposed method is only based on the separation of the fundamental components from the harmonic content of voltage and current; thus, it does not require any spectral analysis of the voltages and current. In this paper, the formulation of the proposed method and its time-domain implementation are described; moreover, some simulation results are …
Cascaded Multilevel Inverter-Based Asymmetric Static Synchronous Compensator of Reactive Power
2022
The topology of the static synchronous compensator of reactive power for a low-voltage three-phase utility grid capable of asymmetric reactive power compensation in grid phases has been proposed and analysed. It is implemented using separate, independent cascaded H-bridge multilevel inverters for each phase. Every inverter includes two H-bridge cascades. The first cascade operating at grid frequency is implemented using thyristors, and the second one—operating at high frequency is based on the high-speed MOSFET transistors. The investigation shows that the proposed compensator is able to compensate the reactive power in a low-voltage three-phase grid when phases are loaded by highly asymmet…
IEEE Std 1459–2010. IEEE Standard Definitions for the Measurement of Electric Power Quantities under Sinusoidal, Nonsinusoidal, Balanced or Unbalance…
2010
Definitions used for measurement of electric power quantities under sinusoidal, nonsinusoidal, balanced, or unbalanced conditions are provided in this standard. Mathematical expressions that were used in the past, as well as new expressions, are listed, as well as explanations of the features of the new definitions.