Search results for "addition"
showing 10 items of 933 documents
Systematic Study of Several Causes and Effects Due to Absorbent Blanks in Determinations of One Analyte
1999
A systematic study is performed about several factors involved in the measurements when a absorbent blank is used, as molar absorption coefficient of the formed complex, absorbance of the blank at the measured wavelength, and kind of spectrophotometer used (conventional double-beam or diode-array). It is proved that the usual methodology, measuring against reagent blank, produces less accurate measurements than those obtained against solvent blank. On the other hand, use of the H-Point standard additions method provides always equal or better results than the best ones obtained at single wavelengths by using measurements against solvent bank, at the maximum of the formed complex. To test th…
Solid sampling Fourier transform infrared determination of Mancozeb in pesticide formulations
2004
Abstract A series of approaches have been assayed for FTIR determination of Mancozeb in several solid commercial fungicides using different calibration strategies. The simplest procedure was based on the use of the ratio between the absorbance of a characteristic band of Mancozeb and that of a KSCN internal standard measured in the FTIR spectra obtained from KBr pellets. It was employed the quotient between peak height absorbance values at 1525 cm−1 for Mancozeb and 2070 cm−1 for KSCN. In these conditions a precision as relative standard deviation (RSD) of 0.6% and a relative accuracy error of 0.8% (w/w) were found. For complex formulations, containing other compounds with characteristic ab…
Creatinine determination in urine samples by batchwise kinetic procedure and flow injection analysis using the Jaffé reaction: chemometric study
2001
The classical Jaffé reaction for the determination of creatinine in urine samples is tested. A comparative study of the main analytical characteristics focussed to minimize the bias error and improve the precision, for the batchwise and flow injection (FI) methods is realized. Also, the effect of the albumin concentration in the determination of creatinine has been studied. Different analytical signals were studied. Absorbance increments at different times permit to estimate the creatinine concentration free from bias error in urine by the batchwise method using the calibration graph obtained with creatinine standards and no measurement of the blank solution is needed. The lineal interval w…
Accommodative response in various design soft contact lens wearers
2021
The progression of myopia in young adults due to inadequate accommodation is currently one of the global research challenges. Studies have demonstrated that multifocal contact lenses have a different effect on accommodative response. The aim of this study was to assess the accommodative lag using various design multifocal contact lenses at different working distances. The study was conducted on 10 emmetropic subjects aged 22â28 years. An open-field autorefractor PowerRef 3 was used to assess the response of eye accommodation to stimuli placed at a distance of 25 cm and 40 cm for subjects wearing monofocal and multifocal contact lenses. To determine the effectiveness of contact lens design f…
Fluorimetric determination of amphetamine in urine by flow injection with on-line liquid–liquid extraction
2001
Abstract Determination of amphetamine in urine was performed by batch and flow injection methodologies. The suitable experimental conditions for fluorimetric measurements were established. The liquid–liquid extraction was carried out at pH 13 using diethyl ether as extracting reagent. The measurement conditions were 260 nm and 277 nm for excitation and emission wavelengths, respectively. The method requires standard addition calibration and Youden blank correction. The influence of the main metabolites of amphetamine and metamphetamine were studied. The accuracy and precision of the proposed method was tested and the method is adapted to the flow injection procedure with on-line extraction.
Effectiveness of microwave based digestion procedures for the demineralization of human milk and infant formulas prior to fluorometric determination …
1996
The use of two types of microwave oven, one domestic (A) and the other specially designed for laboratory (B) for microwave-based digestion, to destroy the organic matter in milk and infant formulas prior to fluorometric determination of selenium is studied in order to check their applicability and reliability. In both systems the best results were obtained using the acid mixture HNO3—H2O2, and additional treatment with perchloric acid (60%) in a Thermoblock. The application of two different microwave-based digestion procedures to infant formulas was free of interferences. In the case of human milk, it was necessary to use the standard addition method. Values obtained for detection and quant…
Double Thermoresponsive Block Copolymers Featuring a Biotin End Group
2010
A poly(oligo(ethylene glycol) monomethyl ether methacrylate)-block-poly(N-isopropyl methacrylamide) (POEGMA-b-PNIPMAM) block copolymer with a biotin end group on the PNIPMAM block as a biotarget was synthesized as a model system for temperature-controlled polymer immobilization. The synthesis was based on RAFT polymerization followed by postpolymerization modification of an activated ester precursor block and an exchange of the dithioester end group within one step. NMR, differential scanning calorimetry (DSC), dynamic light scattering (DLS), and turbidimetry measurements were performed to investigate the stimulus-responsive properties. The double thermoresponsive POEGMA-b-PNIPMAM with biot…
Anionic Polymerization of (Meth)acrylates in the Presence of Cesium Halide−Trialkylaluminum Complexes in Toluene
2001
The polymerization of methyl methacrylate and various acrylates initiated by ester enolates in the presence of cesium halide-trialkylaluminum complexes, Cs[Al n R 2n X] (n = 1, 2; R = Et, Bu'), in toluene has living and controlled character at -20 °C for methacrylates (X = Cl) and at -65 °C for n-butyl acrylate (X = F). Quantitative monomer conversions are usually reached, leading to polymers with narrow molecular weight distributions (M w /M n < 1.1). Kinetic investigations indicate a rather complex polymerization mechanism, and we assume an equilibrium between at least two active species. With this new initiating system, beside acrylate homopolymers, random and graft copolymers can be syn…
Mechanism of Anionic Polymerization of (Meth)acrylates in the Presence of Aluminum Alkyls, 6. Polymerization of Primary and Tertiary Acrylates
1998
The kinetics of the polymerization of n-butyl acrylate initiated by lithiated ester enolates in the presence of aluminum alkyls was investigated in toluene and in toluene/Lewis base mixed solvents at −78 °C. In pure toluene, curved time−conversion plots, incomplete monomer conversion, and broad molecular weight distributions (Mw/Mn ≈ 2) are observedin the absence of aluminum alkyls the molecular weight distributions are significantly broader (Mw/Mn > 14). High monomer conversions and narrower molecular weight distributions (Mw/Mn ≈ 1.5) are obtained when using Lewis bases (e.g., methyl pivalate) as cosolvents. The polymerization of tert-butyl acrylate rapidly reaches full monomer conversion…
Synthesis and solution properties of star-shaped poly(tert-butyl acrylate)
2000
A series of star polymers consisting of poly(tert-butyl acrylate) arms and an ethyleneglycol dimethacrylate (EGDMA) microgel core were synthesized using anionic polymerization. The effect of various parameters (precursor length, ratio [[EGDMA]/[Initiator], reaction time, and overall concentrations) on the average number of arms was investigated. Molecular weights were determined using GPC coupled with an online viscometer and MALLS. The exponents for the relation between intrinsic viscosity or radius of gyration and molecular weight, respectively, are extremely low, indicating that the dimensions of the star polymers only slightly increase with the number of arms. After a certain number of …